Description
• Fast-acting, low breaking capacity
• Optional axial leads available
• 5 x 20mm physical size
• Glass tube with silver-plated (32-125mA) and
nickel-plated (160mA-10A) endcaps
• Designed to IEC 60127-2 (160mA-10A)
Agency Information
• cURus: File E19180, Guide JDYX2, JDYX8
• CSA Component Acceptance: File 1803366
• SEMKO Approval: File 414552
• VDE Approval: File 40014109
• BSI Approval: File KM55676
• IMQ Approval: File CA03.00097
• CCC Approval: File 2005010207155694
Ordering
Specify product code
• Insert packaging code prefix before part number. E.g.
BK/S500-32-R
Specify option code if desired
• For axial leads, insert “V” between catalog series and
amp rating. E.g. S500-V-100-R
Dimensions - mm
Drawing Not to Scale
Specifications
Voltage Interrupting Rating Typical DC Typical Maximum
Part Number Rating (amps) at Rated Cold Resistance Melting I2t Voltage Agency Approvals
Vac Voltage (50Hz) Vac (ΩΩ)* AC† Drop (mV)‡ cURus CSA CCC BSI VDE SEMKO IMQ
S500-32-R 250 35 40 0.000047 3200
S500-40-R 250 35 25 0.00011 2500
S500-50-R 250 35 17 0.00020 2400
S500-63-R 250 35 125 0.00057 2000
S500-80-R 250 35 5.0 0.0012 1200
S500-100-R 250 35 3.8 0.003 1100
S500-125-R 250 35 2.8 0.005 1000
S500-160-R 250 35 9.1 0.008 2000 X X X X X X X
S500-200-R 250 35 6.8 0.016 1700 X X X X X X X
S500-250-R 250 35 4.3 0.28 1400 X X X X X X X
S500-315-R 250 35 3.1 0.58 1300 X X X X X X X
S500-400-R 250 35 2.0 0.18 1100 X X X X X X X
S500-500-R 250 35 0.26 0.18 220 X X X X X X X
S500-630-R 250 35 0.20 0.35 220 X X X X X X X
S500-800-R 250 35 0.14 0.67 190 X X X X X X X
S500-1-R 250 35 0.125 0.60 200 X X X X X X X
S500-1.25-R 250 35 0.096 0.84 200 X X X X X X X
S500-1.6-R 250 35 0.066 1.6 190 X X X X X X X
S500-2-R 250 35 0.043 4.2 150 X X X X X X X
S500-2.5-R 250 35 0.034 6.1 150 X X X X X X X
S500-3.15-R 250 35 0.025 13 130 X X X X X X X
S500-4-R 250 40 0.021 22 130 X X X X X X X
S500-5-R 250 50 0.014 42 120 X X X X X X X
S500-6.3-R 250 63 0.010 69 120 X X X X X X X
S500-8-R 250 80 0.010 N/A 120 X X X X X
S500-10-R 250 100 0.008 N/A 120 X X X X X
* DC Cold Resistance (Measured at <10% of rated current)
† Typical Melting I2t (I2t was measured at listed interrupting rating and rated voltage)
‡ Maximum Voltage Drop (Voltage drop was measured at 20°C ambient temperature at rated current)
Electrical Characteristics
11..55 IInn22..11 IInn22..7755 IInn44 IInn1100 IInn
IInnmmiinnmmaaxxmmiinnmmaaxxmmiinnmmaaxxmmaaxx
32mA-125mA 60 min 30 min – – – – –
160mA-6.3A 60 min 30 min 50 ms 2 sec 10 ms 300 ms 20 ms
8A-10A 30 min 30 min 50 ms 2 sec 10 ms 400 ms 40 ms
5 x 20mm Fuses
S500 Series, Fast-Acting, Glass Tube
0209 BU-SB08761 Page 1 of 2 Data Sheet 2052
• Ratings above 6.3A have a 0.8mm diameter lead