Limit and Enclosed Switches HDLS Series
Rotary Actuated Switches
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA33
Side Rotary Top Rotary
Order guides below and on page A35 pro-
vide specification and pricing information
for side and top rotary switches.
Plug-in body style catalog listings consist of
the complete plug-in base receptacle.
Levers are ordered separately. See pages
A37-A39 for lever selection.
For rapid response – off the shelf service,
all bold face listings are normally stocked
items.
For low temperature, high
temperature or preleading see page
A42.
ASSEMBLED CONDITIONS
Catalog listings in order guide below are
factory assembled with:
1Shaft of side rotary heads facing front of
switch (label side).
1Head adjusted for both clockwise and
counterclockwise operation.
1Light on indicator versions wired to N.O.
circuit.
Refer to facing page to specify modifica-
tions to these assembled conditions.
PRELEADED OR CONNECTORIZED
VERSIONS
Refer to page A42.
ORDER GUIDE (Momentary action. UL listed, CSA certified, CE approved. Levers not included. Order separately pages A37-A39.)
Catalog Listings
Side Rotary Top Rotary
Low
Electrical Body** Low 5°Low Differential High
Circuitry Rating Style Standard Differential Pretravel Torque Low Torque Overtravel
Silver contacts A Plug-in LSA1A LSP1A LSU1A LSR1A LSH1A LSB1A
12NConduit
Gold cross point contacts C Plug-in
12NConduit
LSA1J LSU1J LSB1J
Gold plated contacts C LSA1E LSP1E LSR1E LSH1E
Silver contacts A* 120 V Ind. lite LSA5A LSP5A LSU5A LSR5A LSH5A LSB5A
Plug-In*
12NConduit
A* 240 V Ind. lite LSA8A LSP8A LSU8A LSR8A LSH8A LSB8A
Plug-In
12NConduit
A* 24 V LED lite LSA9A LSP9A LSU9A LSR9A LSH9A LSB9A
1.5mA max.
Auto polarity
Plug-in
12NConduit
A Non plug-in LSA3K LSP3K LSU3K LSR3K LSH3K LSB3K
SPDT Double Break 12NConduit
Silver contacts B Plug-in LSA2B LSP2B LSU2B LSR2B LSH2B LSB2B
34NConduit
B Plug-in LSA6B LSP6B LSU6B LSR6B LSH6B LSB6B
12NConduit
B 120 V Ind. lite
Plug-in
34NConduit
LSA2R LSP2R LSU2R LSR2R LSH2R LSB2R
B Non plug-in LSA4L LSP4L LSU4L LSR4L LSH4L LSB4L
34NConduit
B Non plug-in LSA7L LSP7L LSU7L LSR7L LSH7L LSB7L
12NConduit
DPDT Double Break
D Non plug-in LSA3N LSR3N LSB3N
SPNC Direct Acting 12NConduit
*Use at voltage indicated for light. Wired to N.O. circuit. Upper temperature limit for lighted units is 200°F (93°C). **Plug-in listings include base receptacle.
OPERATING CHARACTERISTICS
Pretravel (degrees max.) 15 9 5 15 9 25
SPDT 5 3 3 5 3 10
Differential Travel
(degrees max.) DPDT 7 4 4 7 4 12
Overtravel (degrees min.) 60 66 70 60 66 110
Operating Torque 0,45 Nm 0,45 Nm 0,45 Nm 0,19 Nm 0,19 Nm 0,28 Nm
(max.) NMJNewton meters 4 in. lbs. 4 in. lbs. 4 in. lbs. 1.7 in. lbs. 1.7 in. lbs. 2.5 in. lbs.
Operating Temperature Range*** 10°F to 250°F30°F to 250°F
–12°to 121°C–1°to 121°C
***Completely fluorocarbon-sealed switches are preferred for use in temperatures above 200°F (93°C). Refer to page A42.
Limit/ Enclosed
Limit and Enclosed Switches HDLS Series
Rotary Actuated Switches
A34Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
ACTUATION DIRECTION
(Drawings apply to listings on facing page only).
CW & CCW CW CCW
(Normal) Mod. 1 Mod. 2
HEAD ORIENTATION
Mod. 5
Mod. 4
Mod. 3
Front
(Normal)
ASSEMBLY MODIFICATIONS
How to order
Momentary action rotary switches can be
furnished in other than the normal assem-
bled conditions described on the facing
page. To specify modifications, add the
number(s) shown below to the catalog list-
ings. Prices are the same as their counter-
parts shown in the order guide.
Modification number suffixes are:
1Clockwise operation only
2Counterclockwise operation only
3Shaft to right of switch front
4Shaft to left of switch front
5Shaft to back of switch
7Indicator light wired to N.C. circuit
Examples:
Catalog Listing LSA1A23 is an LSA1A switch
adjusted for counterclockwise operation
only. The operating shaft is to the right side
of the switch when viewing it from the front
(label side). No lever.
Catalog Listing LSA8A7is an LSA8A switch
with the 240 volt indicator light wired to the
N.C. circuit. No lever.
Switches with assembly modifications are
not normally stocked and may extend deliv-
ery leadtimes.
ELECTRICAL RATINGS
10 amps continuous carry (except for elec-
trical rating ‘‘C’’). Circuits on any one pole
must be the same polarity.
AC Volts
Pilot duty: 600 VAC, 720VA
Electical Amps at 0.35 Power Factor
Rating Circuitry VAC Make Break
A* Single-Pole 120 60 6
Double-Throw 240 30 3
480 15 1.5
600 12 1.2
B Double-Pole 120 30 3
Double-Throw 240 15 1.5
480 7.5 0.75
600 6 0.60
D Single-Pole 120 60 6
Single-Throw 240 30 3
Normally Closed 480 15 1.5
600 12 1.2
C** Single-Pole 250 VAC or 60 VDC, .050 amp max.
Double-Throw
DC Volts
Pilot duty: 240 VDC, 30 watts
Electrical Make and Break Amps
Rating Circuitry VDC Inductive Resistive
A* Single-Pole 120 0.25 0.8
Double-Throw 240 0.15 0.4
B Double-Pole 120 0.25 0.8
Double-Throw 240 0.15 0.4
D Single-Pole 30 4.3 4.3
Single-Throw 120 1.1 1.1
Normally Closed
C** Single-Pole 250 VAC or 60 VDC, .050 amp max.
Double-Throw
*For switches with indicator light, use only at voltage stated for indicator light.
**These switches have either gold plated or gold cross point contacts. Cross point contacts improve high
reliability of contact make when particle contamination is a problem or low energy loads must be carried.
LEVERS
Levers for rotary actuated switches are nor-
mally ordered as separate catalog listings.
They also may be ordered by including a
suffix to the switch catalog listing and add-
ing the lever price. See pages A34-A39.
SWITCHES FOR SPECIAL
APPLICATIONS
HDLS limit switches for special application
needs are described on pages A42 and A43.
They include: manifold mount, low temper-
ature, complete fluorocarbon-sealed, grav-
ity return, extra low torque and 20 Amp
switches.
Adapter plates for interchanging HDLS with
LS/200LS limit switches are described on
page A49.
Limit and Enclosed Switches HDLS Series
Rotary Actuated Switches
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA35
ADDITIONAL CIRCUITRY/ACTION OPTIONS
ORDER GUIDE
Maintained, center neutral, or sequential ac-
tion. UL listed, CSA certified. Levers not in-
cluded (see pages A36-A39).
ASSEMBLY MODIFICATIONS
Switches in the order guide, below, have the
operating shaft facing front. If another orien-
tation is desired, add a number from the
drawing to the catalog listing.
To specify the indicator light wired to the
N.C. circuit, add 7to the catalog listing.
Example:
Catalog Listing LSN5A37 is an LSN5A
switch with the shaft facing right and the
indicator light wired to the N.C. circuit.
HEAD ORIENTATION
(Drawing applies to this page only.)
Mod. 5
Mod. 4
Mod. 3
Front
(Normal)
Lever ordering information is shown on
pages A36-A39.
For low temperature, all Viton or preleaded versions see page A42.
Elec. Maintained† Center Neutral Sequential
Rating Body** 360°Alternate 2 Position (Pole 1 operates CCW (Pole 1 operates before Pole 2,
Circuitry Page A23 Style Action Standard Pole 2 operates CW) either CW or CCW or both)
SPDT Double Break
Maintained
CENTER NEUTRAL
SPDT Double Break
each direction
Electrical rating B
SEQUENCE
(2) SPDT Double Break
with 10°between operation
Electrical rating B
A Plug-in LSQ300 LSN1A
12NConduit
A* 120V Ind. Lite LSN5A
Plug-in
12NConduit
A* 240V Ind. Lite LSN8A
Plug-in
12NConduit
A Non plug-in LSQ310 LSN3K
12NConduit
B Plug-in LSN2B LSM2D LSL2C
34NConduit
B Plug-in LSN6B LSM6D LSL6C
12NConduit
B Non plug-in LSQ320 LSN4L LSM4N LSL4M
34NConduit
B Non plug-in LSN7L LSM7N LSL7M
12NConduit
DPDT Double Break
Maintained
D Non plug-in LSN3N
12NConduit
SP Normally Closed
Direct Acting
* Use at voltage indicated for light. Wired to N.O.
circuit.
Upper temperature for lighted units is 200°F (93°C).
** Plug-in listings include base receptacle. Total travel is approximately 80°max. Maintained
contact switch normally used with LSZ53 yoke actua-
tor.
OPERATING CHARACTERISTICS
Pretravel (degrees max.) SPDT 65 Not Applicable Not Applicable
Note: Mechanical trip DPDT 65 18 1st Pole 15
before electrical trip 2nd Pole 10 additional (max.)
SPDT 40 Not Applicable Not Applicable
Differential Travel
(degrees max.) DPDT 40 10 For each pole — 5 degrees
Overtravel (degrees min.) 20 57 48
Operating Torque Nm JNewton meters 0,45 Nm 0,45 0,45
(max.) 4 in. lbs. 4 in. lbs. 4 in. lbs.
Operating Temperature
Range***
30°F to 250°F10°F to 250°F
–1 to 121°C –12 to 121°C
*** Completely fluorocarbon-sealed switches are preferred for temperatures above 200°F (93°C). Refer to page A42.
Limit/ Enclosed
Limit and Enclosed Switches HDLS Series
Levers for Rotary Actuated Switches
A36Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
LSZ51 LSZ55 LSZ53
Type Type Type
LSZ52 LSZ54 LSZ61
Type Type Type
CAM TRACKING LSZ51 TYPE LEVERS LSZ52 TYPE LEVER
Open mounted roller Close mounted roller
LSZ54 TYPE LEVER LSZ55 TYPE LEVERS
Open mounted roller Close mounted roller
NOTE: Shaft dia. is .29 in.
Levers for use with side or top rotary actuat-
ed switches are available in a wide choice of
sizes and materials, as shown in the order
guides on the following pages. Rollers may
be on either side of the lever to best match
the external actuating mechanism. They
permit a wide range of cam tracking possi-
bilities (see drawings below).
LSZ51 standard rollers and LSZ55 offset
roller levers have a fixed 1.5 inch (38,1 mm)
radius.
LSZ53 yoke roller levers are used with side
rotary maintained switches, where a reci-
procating actuator operates the switch in
one direction and reverses it when moving
in the other direction.
LSZ52 adjustable length roller levers are
universally adaptable to many application
needs.
LSZ54 rod levers may be formed by the
user. The hub permits adjusting of lever
length. Also available in flexible versions.
LSZ61 is an adjustable loop lever.
For lever order guides, refer to the following
pages.
Limit and Enclosed Switches HDLS Series
Levers for Rotary Actuated Switches
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA37
Rollers may be mounted on the front or back side of the lever. (See below).
FRONT MOUNT BACK MOUNT
Levers shown in the order guides are fur-
nished with cap screws which accommo-
date a 964-inch allen wrench.
ORDER GUIDE
Roller
Mounted On
RadiusThis SideDia.Width
Type(in.)Of Leverin.in.MaterialCatalog Listings
LSZ51 Series1.5Front.75.25NylonLSZ51A
Std.1.5Front.75.25SteelLSZ51B
Roller1.5Back.75.25NylonLSZ51C
Lever1.5Back.75.25SteelLSZ51D
1.5Front1.0.50NylonLSZ51F
1.5Front1.5.25NylonLSZ51G
1.5Back1.0.50NylonLSZ51J
1.5Back.75.25Ball BearingLSZ51L
1.5Back.751.30NylonLSZ51M
1.5Back.75.375StainlessLSZ51T
1.5Front.75.50NylonLSZ51P
1.5Front1.59.25NylonLSZ51R
1.5Less RollerLSZ51
LSZ53 Series1.5Front-Back.75.25NylonLSZ53A
Yoke1.5Front-Back.75.25SteelLSZ53B
1.5Front-Front.75.25SteelLSZ53D
1.5Back-Front.75.25NylonLSZ53E
1.5Back-Back.75.25NylonLSZ53S
1.5Back-Back.75.25SteelLSZ53P
1.5Back-Front.75.25SteelLSZ53U
1.5Back-Front.751.25NylonLSZ53M
1.5Less RollersLSZ53
Back view of LSZ53E
LSZ55 Series1.5Less RollerLSZ55
Offset1.5Back.75.25NylonLSZ55A
1.5Back.75.25SteelLSZ55B
1.5Front.75.25NylonLSZ55C
1.5Front.75.25SteelLSZ55D
1.5Front.75.50NylonLSZ55E
1.5Front1.5.25NylonLSZ55K
1.5Front1.0.50NylonLSZ55F
LSZ69 Series*6.0 Stainless LSZ69CA
(spokes
replaceable)
*For use with LSQ300 Series. Hub is aluminum. See page A59 for dimensions.
Teller Tab
Teller tab assures proper torque.
When it cannot be moved, the lever is
tight enough to prevent slippage.
Limit/ Enclosed
Limit and Enclosed Switches HDLS Series
Levers for Rotary Actuated Switches
A38Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
METRIC CONVERSION
.25 in. J6,35 mm
.5 in. J12,7 mm
.625 in. J15,9 mm
.75 in. J19,1 mm
1.0 in. J25,4 mm
1.5 in. J38,1 mm
2.0 in. J50,8 mm
2.5 in. J63,5 mm
3.0 in. J76,2 mm
4.8 in. J122 mm
5.0 in. J127 mm
6.0 in. J152 mm
12.0 in. J305 mm
LOW TORQUE APPLICATION
CONSIDERATION
When heavier levers (such as LSZ52 series
and LSZ54 series, below), are used with low
torque LSH, LSR, LSS and LST switches, it is
desirable to mount the switch with the lever
down. In this way, gravity will assist in restor-
ing levers to the free position.
Conversely, when these switches are
mounted with the lever upright, gravity
tends to work to prevent lever return after
switching actuation. By counterbalancing
the lever or adding an auxiliary extension
spring, this problem may be overcome.
Contact the 800 number for application as-
sistance.
ORDER GUIDE
Roller
Mounted On
RadiusThis SideDia.Width
Type(in.)Of Leverin.in.MaterialCatalog Listings
stings
LSZ52 Series1.5-3.5Back.75.25NylonLSZ52A
Adjustable1.5-3.5Back.75.25SteelLSZ52B
Radius1.5-3.5Front.75.25NylonLSZ52C
1.5-3.5Front.75.25SteelLSZ52D
1.5-3.5Front.751.30NylonLSZ52E
1.5-3.5Front1.0.5NylonLSZ52J
1.5-3.5Front1.5.25NylonLSZ52K
1.5-3.5Front.75.25Ball BearingLSZ52L
1.5-3.5Front2.0.25NylonLSZ52M
1.5-3.5Front.75.5NylonLSZ52N
Less RollerLSZ52
Hub OnlyLSZ54
LSZ68 Series 12.0 .25 Delrin Rod
w/SpringLSZ68
Spring/Rod 16.0 .25 Delrin Rod
w/SpringLSZ617
LSZ54 Series5.5AluminumLSZ54M
Rod13.0Stainless SteelLSZ54N
20.0Delrin RodLSZ54P
12.0Spring WireLSZ54R
4.8Flexible CableLSZ54V*
Hub OnlyLSZ54
LSZ61 Series
Flexible Loop
NylatronLSZ616NFlexible Loop/Cap Screw
LSZ6189.5NFlexible Loop/Cap Screw
Hub OnlyLSZ54
(measured from center line of shaft
hole to tip of actuator)
LSZ60 SeriesFront.75.25NylonLSZ60A
One WayFront.75.25SteelLSZ60B
Roller Lever
See page A60 for dimensions *Hub not available separately.
Limit and Enclosed Switches HDLS Series
Levers for Rotary Actuated Switches
Honeywell1Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA39
FIXED LENGTH LEVERS ORDER GUIDE
For a complete listing add your choice of roller suffix
Fixed Length Levers
LSZ65 Series
Lever
Length (in.)
Lever
Listing
Roller
Suffix
Dia.
in.
Width
in. Material
.88 LSZ65A A .75 .25 Nylon
1.38 LSZ65B B .75 .25 Steel
1.25 LSZ65L
1.50 LSZ65C C .75 .50 Nylon
1.75 LSZ65D D .75 1.30 Nylon
2.00 LSZ65E E 1.00 .50 Nylon
2.50 LSZ65F F 1.50 .25 Nylon
3.00 LSZ65G
4.00 LSZ65H
5.00 LSZ65J
6.00 LSZ65K
Example:
LSZ65AB is a .88Nlong lever with a steel .75Ndiameter, .25Nwide roller.
RUBBER ROLLER LEVERS
Ideal for elevator or conveyor applications
requiring quiet operation or protection of
delicate surfaces.
ORDER GUIDE
Roller
Mounted On
Radius This Side Dia. Width Catalog
Type (in.) Of Lever in. in. Material Listing
LSZ51 Series
Std.
Roller
Lever
1.5 Front 1.6 .5 Rubber LSZ51W
1.5 Front 2.0 .5 Rubber LSZ51Y
LSZ55 Series
Offset
1.5 Front 1.6 .50 Rubber LSZ55W
1.5 Front 2.0 .50 Rubber LSZ55Y
LSZ52 Series
Adjustable
Radius
1.5 to 3.5 Front 1.6 .50 Rubber LSZ52W
1.5 to 3.5 Front 2.0 .50 Rubber LSZ52Y
LSZ67 Series
Conveyor
Roller
1.5 3.8 Plastic LSZ67AA
Limit/ Enclosed
Limit and Enclosed Switches HDLS Series
Plunger Actuated Switches
A40Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
ASSEMBLED CONDITIONS
Catalog listings in order guide below are
factory assembled with:
1Side plungers facing front (label side) of
switch. Rollers on side plungers are in
horizontal position.
ORDER GUIDE
Momentary action, except for maintained
contact LSG version. UL listed, CSA
certified.
1Roller on top plungers are parallel to
mounting surface.
1Lights on indicator versions are wired to
N.O. circuit.
Refer to facing page to specify modifica-
tions to these assembled conditions.
For low temperature, high temperature
or preleaded versions see page A42.
Circuitry For Maintained Plunger
SPDT Double Break DPDT Double Break
(Electrical rating A) (Electrical rating B)
Circuits on any one pole must be the same polarity.
Catalog Listings
Top Plungers Side Plungers
Catalog listings in this chart
are complete switches.
Elec. Maintained
(Circuitry
Shown
Above)
Rating Body**
Circuitry Page A34 Style Plain Roller Adjustable Plain Roller Adjustable
Silver contacts A Plug-in LSC1A LSD1A LSV1A LSE1A LSF1A LSW1A LSG1A
12NConduit
Gold cross pt.
Gold plated C
C Plug-in LSC1J LSD1J LSV1J LSE1J LSF1J LSW1J
12NConduit LSD1E LSF1E LSW1E
Silver contacts A* 120 V. Ind. Lite LSC5A LSD5A LSV5A LSE5A LSF5A LSW5A LSG5A
Plug-in
12NConduit*
A* 240 V. Ind. Lite LSC8A LSD8A LSV8A LSE8A LSF8A LSW8A LSG8A
Plug-in
12NConduit*
A Non plug-in LSC3K LSD3K LSV3K LSE3K LSF3K LSW3K LSG3K
12NConduit
SPDT
Double Break
Silver contacts B Plug-in LSC2B LSD2B LSV2B LSE2B LSF2B LSW2B LSG2B
34NConduit
B 120 V Ind. Lite LSC2R LSD2R LSV2R LSE2R LSF2R LSW2R LSG2R
Plug-in
34NConduit
B Plug-in LSC6B LSD6B LSV6B LSE6B LSF6B LSW6B LSG6B
12NConduit
B Non plug-in LSC4L LSD4L LSV4L LSE4L LSF4L LSW4L LSG4L
34NConduit
B Non plug-in LSC7L LSD7L LSV7L LSE7L LSF7L LSW7L LSG7L
12NConduit
DPDT
Double Break
D Non plug-in LSE3N LSF3N LSW3N LSG3N
12NConduit
SPNC
Direct Acting
*Use at voltage indicated for light. Upper operating temperature limit for lighted units is 200°F. Wired to N.O. circuit. ** Plug-in listings include base receptacle.
OPERATING CHARACTERISTICS
mm 1,78 1,78 1,78 2,54 2,54 2,54 4,32
Pretravel (in. max.) .070 .070 .070 .100 .100 .100 .170
0,38 0,38 0,38 0,64 0,64 0,64 2,29
SPDT .015 .015 .015 .025 .025 .025 .090
Differential mm 0,51 0,51 0,51 0,89 0,89 0,89 2,29
Travel (in. max.) DPDT .020 .020 .020 .035 .035 .035 .090
mm 4,83 4,83 4,83 4,83 4,83 4,83 2,0
Overtravel (in. min.) .190 .190 .190 .190 .190 .190 .080
Newton 17,8 17,8 17,8 26,7 26,7 26,7 44,5
Operating Force (lb. max.) 4 4 4 6 6 6 10
Operating Point mm
(in.)
45,8 ±0,76 55,9 ±1,02 53,0 to 59,3 33,0 ±0,76 44,1 ±1,02 41,0 to 47,4 37,6 ±0,76
1.805 ±.030 2.200 ±.040 2.085 to 2.335 1.300 ±.030 1.735 ±.040 1.615 to 1.865 1.480 ±.030
Operating Temperature
Range
10°F to 200°F10°F to 200°F10°F to 200°F30°F to 200°F
–12 to 93°C –12 to 93°C –12 to 93°C –1 to 93°C
Limit and Enclosed Switches HDLS Series
Plunger Actuated Switches/Assembly Modifications
Honeywell1Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA41
ASSEMBLY MODIFICATIONS
How to order
To specify other than the normal assembled
conditions described on facing page, add
the following modification numbers to the
catalog listing in the plunger switch order
guide.
Mod.
3Side plunger to right of switch front
4Side plunger to left of switch front
5Side plunger to back of switch
6Roller on top plungers perpendicular to
mounting surface
7Light on indicator versions wired to N.C.
circuit
8Roller on side plungers in vertical posi-
tion.
Example:
LSF1A3 is an LSF1A with the side roller plun-
ger to the right side.
Wobble Actuated Switches
Wobble actuated switches have flexible lev-
ers which may be operated with any move-
ment, except direct pull.
ORDER GUIDE
Momentary action. UL listed, CSA certified
Catalog Listings
Catalog listings in this chart
are complete switches.
Lever lengths measured from top mounting hole 5.5N13N5.5N5.5N5.5N
Elec.
Rating Body** Delrin Spring Cat*** Coil
Circuitry Page A34 Style Rod Wire Whisker Cable Spring
Silver contacts A Plug-in LSJ1A-7A LSJ1A-7M LSK1A-8A LSJ1A-7N LSK1A-8C
12NConduit
Gold cross point C Plug-in LSJ1J-7A LSJ1J-7M LSK1J-8A LSJ1J-7N LSK1J-8C
12NConduit LSJ1E-7M
Gold plated contacts C
Silver contacts A* 120 V. Ind. Lite LSJ5A-7A LSJ5A-7M LSK5A-8A LSJ5A-7N LSK5A-8C
Plug-in
12NConduit*
A* 240 V. Ind. Lite LSJ8A-7A LSJ8A-7M LSK8A-8A LSJ8A-7N LSK8A-8C
Plug-in
12NConduit*
A Non plug-in LSJ3K-7A LSJ3K-7M LSK3K-8A LSJ3K-7N LSK3K-8C
12NConduit
SPDT Double Break
Silver contacts B Plug-in LSJ2B-7A LSJ2B-7M LSK2B-8A LSJ2B-7N LSK2B-8C
34NConduit
B 120 V Ind. Lite LSJ2R-7A LSJ2R-7M LSK2R-8A LSJ2R-7N LSK2R-8C
Plug-In
34NConduit
B Plug-in LSJ6B-7A LSJ6B-7M LSK6B-8A LSJ6B-7N LSK6B-8C
12NConduit
B Non plug-in LSJ4L-7A LSJ4L-7M LSK4L-8A LSJ4L-7N LSK4L-8C
34NConduit
B Non plug-in LSJ7L-7A LSJ7L-7M LSK7L-8A LSJ7L-7N LSK7L-8C
12NConduit
DPDT Double Break
OPERATING CHARACTERISTICS
mm 25,4 102 51 38 51
Pretravel (approx. in. radius) 1 4 2 1.5 2
Newton 2,78 1,39 1,39 1,95 1,95
Operating Force (oz. max.) 10 5 5 7 7
Operating Temperature Range 10°F to 200°F 12 to 93°C
* Use at voltage indicated for light. Upper operating temper-
ature limit for lighted units is 200°F.
** Plug-in listings include base recep-
tacle.
*** These cat whiskers have 512inch long levers. To specify
712inch length, substitute -8B for -8A.
Limit/ Enclosed
Limit and Enclosed Switches HDLS Series
Modification and Replacement Parts
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA49
Non plug-in type Plug-in type
REPLACEMENT WOBBLE ACTUATORS
Catalog Listing
Delrin Spring Cat Coil
Rod Wire Cable Whisker Spring
LSZ4009 LSZ4010 LSZ4011 LSZ4012* LSZ4014
*5
1
2inch long. For 712Nlength, order LSZ4013.
MICRO SWITCH conduit sealing packets
can be used with limit or enclosed switches.
This includes the HDLS, Compact LS, ML,
E6, V6, BAF1 or OP series switches.
The conduit sealing packets are not suitable
for use with explosion-proof switches.
PLUG IN RECEPTACLES
Type Catalog Listing
Single-Pole LSZ4001
Double-Pole LSZ4002
34in. Conduit
Double-Pole LSZ4006
12in. Conduit
Single-Pole LSZ4015
Manifold Mount
Double-Pole LSZ4016
Manifold Mount
ADAPTER PLATES
These adapter plates enable HDLS plug-in
switches to retrofit 200LS series (single-
pole) and 300LS series (double-pole) plug-
in switches.
Catalog
Type Listing
Adapts 200LS series LSZ4003
mounting to accept HDLS
Adapts 300LS series LSZ4004
mounting to accept HDLS
INDICATOR LIGHTS/SEAL RING
Type Catalog Listing
120V LSZ4007
240V LSZ4008
ADJUSTING TOOL KIT
This tool kit is used if readjustment of switch-
es is necessary when heads and/or contact
blocks are replaced.
Catalog Listing
LSZ4005
REPLACEMENT LEVERS
To order replacement levers, specify the
same part number that is metal stamped on
either the lever or lever hub.
For a complete list of HDLS replacment
parts, refer to the charts on the following
pages.
CONDUIT SEALING PACKETS
Catalog
Listing
Packet Cable O.D. Inches
2PA6 .400N- .435N
2PA16 .435N- .470N
2PA1 .530N- .570N
LIQUID TIGHT CONDUIT FITTING
2PA17.170" - .470" ½ NPT
2PA19 .450" - .709" ¾ NPT
Limit/ Enclosed
Limit and Enclosed Switches HDLS Series
Replacement Parts
A50Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
For low temperature or high temperature options, refer to example in LSA1A block.
PLUG-IN TYPE 12345
Catalog Complete Plug-in
Listing* Plug-in Unit Base Operating Contact
On Switch Less Base Receptacle Head Block Actuator
Nameplate Receptacle Only Only† Only Only
Std. LSA1A LSZ7A1A LSZ4001 LSZ1A LSZ3A
Low Temp. LSYAB1A LSZ7YAB1A LSZ4001 LSZ1AB LSZ3A
High Temp. LSYAC1A LSZ7YAC1A LSZ4001 LSZ1AC LSZ3A
LSA5A LSZ7A5A LSZ4001 LSZ1A LSZ3A
LSA8A LSZ7A8A LSZ4001 LSZ1A LSZ3A
LSA1J LSZ7A1J LSZ4001 LSZ1A LSZ3J
LSA2B LSZ7A2B LSZ4002 LSZ1A LSZ3B
LSA6B LSZ7A6B LSZ4006 LSZ1A LSZ3B
LSB1A LSZ7B1A LSZ4001 LSZ1B LSZ3A
LSB1J LSZ7B1J LSZ4001 LSZ1B LSZ3J
LSB5A LSZ7B5A LSZ4001 LSZ1B LSZ3A
LSB8A LSZ7B8A LSZ4001 LSZ1B LSZ3A
LSB2B LSZ7B2B LSZ4002 LSZ1B LSZ3B
LSB6B LSZ7B6B LSZ4006 LSZ1B LSZ3B
LSC1A LSZ7C1A LSZ4001 LSZ1C LSZ3A
LSC1J LSZ7C3J LSZ4001 LSZ1C LSZ3J
LSC5A LSZ7C5A LSZ4001 LSZ1C LSZ3A
LSC8A LSZ7C8A LSZ4001 LSZ1C LSZ3A
LSC2B LSZ7C2B LSZ4002 LSZ1C LSZ3B
LSC6B LSZ7C6B LSZ4006 LSZ1C LSZ3B
LSD1A LSZ7D1A LSZ4001 LSZ1D LSZ3A
LSD1J LSZ7D1J LSZ4001 LSZ1D LSZ3J
LSD2B LSZ7D2B LSZ4002 LSZ1D LSZ3B
LSD5A LSZ7D5A LSZ4001 LSZ1D LSZ3A
LSD8A LSZ7D8A LSZ4001 LSZ1D LSZ3A
LSD6B LSZ7D6B LSZ4006 LSZ1D LSZ3B
LSE1A LSZ7E1A LSZ4001 LSZ1E LSZ3A
*Only partial listings are shown and necessary to
determine replacement parts catalog listing. The list-
ings with -7A, -7M, -7N, -8A, -8B and -8C are complete
catalog listings.
Note: Complete units consist of Columns 1 and 2. †For low temperature replacement heads add
B. Example LSZ1AB. For fluorocarbon seal
replacement heads add C. Example LSZ1AC.
Limit and Enclosed Switches HDLS Series
Replacement Parts
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA51
PLUG-IN TYPE (Continued) 1 2345
Catalog Complete Plug-in
Listing* Plug-in Unit Base Operating Contact
On Switch Less Base Receptacle Head Block Actuator
Nameplate Receptacle Only Only† Only Only
LSE1J LSZ7E1J LSZ4001 LSZ1E LSZ3J
LSE2B LSZ7E2B LSZ4002 LSZ1E LSZ3B
LSE5A LSZ7E5A LSZ4001 LSZ1E LSZ3A
LSE8A LSZ7E8A LSZ4001 LSZ1E LSZ3A
LSE6B LSZ7E6B LSZ4006 LSZ1E LSZ3B
LSF1A LSZ7F1A LSZ4001 LSZ1F LSZ3A
LSF1J LSZ7F1J LSZ4001 LSZ1F LSZ3J
LSF2B LSZ7F2B LSZ4002 LSZ1F LSZ3B
LSF5A LSZ7F5A LSZ4001 LSZ1F LSZ3A
LSF8A LSZ7F8A LSZ4001 LSZ1F LSZ3A
LSF6B LSZ7F6B LSZ4006 LSZ1F LSZ3B
LSG1A LSZ7G1A LSZ4001 LSZ1G
LSG5A LSZ7G5A LSZ4001 LSZ1G
LSG8A LSZ7G8A LSZ4001 LSZ1G
LSG2B LSZ7G2B LSZ4002 LSZ1G
LSG6B LSZ7G6B LSZ4006 LSZ1G
LSH1A LSZ7H1A LSZ4001 LSZ1H LSZ3A
LSH2B LSZ7H2B LSZ4002 LSZ1H LSZ3B
LSH6B LSZ7H6B LSZ4006 LSZ1H LSZ3B
LSH5A LSZ7H5A LSZ4001 LSZ1H LSZ3A
LSH8A LSZ7H8A LSZ4001 LSZ1H LSZ3A
LSJ1A-7A LSZ7J1A-7A LSZ4001 LSZ1JGA** LSZ3A LSZ4009
LSJ1A-7M LSZ7J1A-7M LSZ4001 LSZ1JGM** LSZ3A LSZ4010
*Only partial listings are shown and necessary to
determine replacement parts catalog listing. The list-
ings with -7A, -7M, -7N, -8A, -8B and -8C are complete
catalog listings.
**Includes actuator
Note: Complete units consist of Columns 1 and 2. For low temperature replacement heads add
B. Example LSZ1AB. For fluorocarbon seal
replacement heads add C. Example LSZ1AC.
Limit/ Enclosed
Limit and Enclosed Switches HDLS Series
Replacement Parts
A52Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
PLUG-IN TYPE (Continued) 1 2345
Catalog Complete Plug-in
Listing* Plug-in Unit Base Operating Contact
On Switch Less Base Receptacle Head and Block Actuator
Nameplate Receptacle Only Actuator‡ Only Only
LSJ5A-7M LSZ7J5A-7M LSZ4001 LSZ1JGM LSZ3A LSZ4010
LSJ8A-7M LSZ7J8A-7M LSZ4001 LSZ1JGM LSZ3A LSZ4010
LSJ2B-7A LSZ7J2B-7A LSZ4002 LSZ1JGM LSZ3B LSZ4009
LSJ2B-7M LSZ7J2B-7M LSZ4002 LSZ1JGM LSZ3B LSZ4010
LSJ6B-7M LSZ7J6B-7M LSZ4006 LSZ1JGM LSZ3B LSZ4010
LSJ5A-7A LSZ7J5A-7A LSZ4001 LSZ1JGA LSZ3A LSZ4009
LSJ8A-7A LSZ7J8A-7A LSZ4001 LSZ1JGA LSZ3A LSZ4009
LSJ6B-7A LSZ7J6B-7A LSZ4006 LSZ1JGA LSZ3B LSZ4009
LSJ1A-7N LSZJ1A-7N LSZ4001 LSZ1JGN LSZ3A LSZ4011
LSJ1J-7N LSZ7J1J-7N LSZ4001 LSZ1JGN LSZ3J LSZ4011
LSJ5A-7N LSZ7J5A-7N LSZ4001 LSZ1JGN LSZ3A LSZ4011
LSJ8A-7N LSZ7J8A-7N LSZ4001 LSZ1JGN LSZ3A LSZ4011
LSJ2B-7N LSZ7J2B-7N LSZ4002 LSZ1JGN LSZ3B LSZ4011
LSJ6B-7N LSZ7J6B-7N LSZ4006 LSZ1JGN LSZ3B LSZ4011
LSK1A-8A LSZ7K1A-8A LSZ4001 LSZ1KHA LSZ3A LSZ4012
LSK1J-8A LSZ7K1J-8A LSZ4001 LSZ1KHA LSZ3J LSZ4012
LSK2B-8A LSZ7K2B-8A LSZ4002 LSZ1KHA LSZ3B LSZ4012
LSK5A-8A LSZ7K5A-8A LSZ4001 LSZ1KHA LSZ3A LSZ4012
LSK8A-8A LSZ7K8A-8A LSZ4001 LSZ1KHA LSZ3A LSZ4012
LSK6B-8A LSZ7K6B-8A LSZ4006 LSZ1KHA LSZ3B LSZ4012
LSK1A-8C LSZ7K1A-8C LSZ4001 LSZ1KHC LSZ3A LSZ4014
LSK1A-8B LSZ7K1A-8B LSZ4001 LSZ1KHB LSZ3A LSZ4013
LSK5A-8C LSZ7K5A-8C LSZ4001 LSZ1KHC LSZ3A LSZ4014
LSK8A-8C LSZ7K8A-8C LSZ4001 LSZ1KHC LSZ3A LSZ4014
LSK2B-8C LSZ7K2B-8C LSZ4002 LSZ1KHC LSZ3B LSZ4014
LSK6B-8C LSZ7K6B-8C LSZ4006 LSZ1KHC LSZ3B LSZ4014
*Only partial listings are shown and necessary to
determine replacement parts catalog listing. The list-
ings with -7A, -7M, -7N, -8A, -8B and -8C are complete
catalog listings.
Note: Complete units consist of Columns 1 and 2. For low temperature replacement head and actua-
tors add Bbetween the fifth and sixth characters.
Example: LSZ1KBHA. For fluorocarbon seals add
C. Example LSZ1KCHA.
Limit and Enclosed Switches HDLS Series
Replacement Parts
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA53
PLUG-IN TYPE (Continued) 1 2345
Catalog Complete Plug-in
Listing* Plug-in Unit Base Operating Contact
On Switch Less Base Receptacle Head Block Actuator
Nameplate Receptacle Only Only† Only Only
LSL2C LSZ7L2C LSZ4002 LSZ1L LSZ3C
LSL6C LSZ7L6C LSZ4006 LSZ1L LSZ3C
LSM2D LSZ7M2D LSZ4002 LSZ1M LSZ3C
LSM6D LSZ7M6D LSZ4006 LSZ1M LSZ3C
LSN1A LSZ7N1A LSZ4001 LSZ1N
LSN2B LSZ7N2B LSZ4002 LSZ1N
LSN5A LSZ7N5A LSZ4001 LSZ1N
LSN8A LSZ7N8A LSZ4001 LSZ1N
LSN6B LSZ7N6B LSZ4006 LSZ1N
LSP1A LSZ7P1A LSZ4001 LSZ1P LSZ3A
LSP1J LSZ7P1J LSZ4001 LSZ1P LSZ3J
LSP2B LSZ7P2B LSZ4002 LSZ1P LSZ3B
LSP5A LSZ7P5A LSZ4001 LSZ1P LSZ3A
LSP8A LSZ7P8A LSZ4001 LSZ1P LSZ3A
LSP6B LSZ7P6B LSZ4006 LSZ1P LSZ3B
LSR1A LSZ7R1A LSZ4001 LSZ1R LSZ3A
LSR2B LSZ7R2B LSZ4002 LSZ1R LSZ3B
LSR6B LSZ7R6B LSZ4006 LSZ1R LSZ3B
LSR5A LSZ7R5A LSZ4001 LSZ1R LSZ3A
*Only partial listings are shown and necessary to
determine replacement parts catalog listing. The list-
ings with -7A, -7M, -7N, -8A, -8B and -8C are complete
catalog listings.
Note: Complete units consist of Columns 1 and 2. For low temperature replacement heads add B.
Example LSZ1AB. For fluorocarbon seal replace-
ment heads add C. Example LSZ1AC.
Limit/ Enclosed
Limit and Enclosed Switches HDLS Series
Replacement Parts
A54Honeywell1Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
PLUG-IN TYPE (Continued) 1 2345
Catalog Complete Plug-in
Listing* Plug-in Unit Base Operating Contact
On Switch Less Base Receptacle Head Block Actuator
Nameplate Receptacle Only Only† Only Only
LSR8A LSZ7R8A LSZ4001 LSZ1R LSZ3A
LSS1H LSZ7S1H LSZ4001 LSZ1S LSZ3H
LSU1A LSZ7U1A LSZ4001 LSZ1U LSZ3A
LST1H LSZ7T1H LSZ4001 LSZ1T LSZ3H
LSU5A LSZ7U5A LSZ4001 LSZ1U LSZ3A
LSV1A LSZ7V1A LSZ4001 LSZ1V LSZ3A
LSV1J LSZ7V1J LSZ4001 LSZ1V LSZ3J
LSV5A LSZ7V5A LSZ4001 LSZ1V LSZ3A
LSV8A LSZ7V8A LSZ4001 LSZ1V LSZ3A
LSV2B LSZ7V2B LSZ4002 LSZ1V LSZ3B
LSV6B LSZ7V6B LSZ4006 LSZ1V LSZ3B
LSW1A LSZ7W1A LSZ4001 LSZ1W LSZ3A
LSW1J LSZ7W1J LSZ4001 LSZ1W LSZ3J
LSW5A LSZ7W5A LSZ4001 LSZ1W LSZ3A
LSW8A LSZ7W8A LSZ4001 LSZ1W LSZ3A
LSW2B LSZ7W2B LSZ4002 LSZ1W LSZ3B
LSW6B LSZ7W6B LSZ4006 LSZ1W LSZ3B
NON PLUG-IN TYPE (These parts will not form a complete switch)
Catalog
Listing* Operating Contact
On Switch Head Block Actuator
Nameplate Only† Only Only
LSA3K LSZ1A LSZ3K
LSA4L LSZ1A LSZ3L
LSA7L LSZ1A LSZ3L
LSB3K LSZ1B LSZ3K
LSB4L LSZ1B LSZ3L
LSB7L LSZ1B LSZ3L
LSC3K LSZ1C LSZ3K
LSC4L LSZ1C LSZ3L
Catalog
Listing* Operating Contact
On Switch Head and Block Actuator
Nameplate Actuator‡ Only Only
LSJ7L-7A LSZ1JGA LSZ3L LSZ4009
LSJ7L-7M LSZ1JGM LSZ3L LSZ4010
LSJ4L-7N LSZ1JGN LSZ3L LSZ4011
LSJ7L-7N LSZ1JGN LSZ3L LSZ4011
LSK3K-8A LSZ1KHA LSZ3K LSZ4012
LSK4L-8A LSZ1KHA LSZ3L LSZ4012
LSK7L-8A LSZ1KHA LSZ3L LSZ4012
LSK3K-8C LSZ1KHC LSZ3K LSZ4014
*Only partial listings are shown and necessary to
determine replacement parts catalog listing. The list-
ings with -7A, -7M, -7N, -8A, -8B and -8C are complete
catalog listings.
Note: Complete units consist of Columns 1 and 2. For low temperature replacement head and actua-
tors add Bbetween the fifth and sixth characters.
Example LSZ1KBHA. For fluorocarbon seals add C.
Example LSZ1KCHA.
Limit and Enclosed Switches HDLS Series
Replacement Parts
Honeywell1Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 CanadaA55
NON PLUG-IN TYPE
Catalog
Listing* Operating Contact
On Switch Head Block Actuator
Nameplate Only† Only Only
LSC7L LSZ1C LSZ3L
LSD3K LSZ1D LSZ3K
LSD4L LSZ1D LSZ3L
LSD7L LSZ1D LSZ3L
LSE3K LSZ1E LSZ3K
LSE4L LSZ1E LSZ3L
LSE7L LSZ1E LSZ3L
LSF3K LSZ1F LSZ3K
LSF4L LSZ1F LSZ3L
LSF7L LSZ1F LSZ3L
LSG3K LSZ1G
LSG4L LSZ1G
LSG7L LSZ1G
LSH3K LSZ1H LSZ3K
LSH4L LSZ1H LSZ3L
LSH7L LSZ1H LSZ3L
Catalog
Listing* Operating Contact
On Switch Head and Block Actuator
Nameplate Actuator‡ Only Only
LSJ3K-7A LSZ1JGA LSZ3K LSZ4009
LSJ3K-7M LSZ1JGM LSZ3K LSZ4010
LSJ3K-7N LSZ1JGN LSZ3K LSZ4011
LSJ4L-7A LSZ1JGA LSZ3L LSZ4009
LSJ4L-7M LSZ1JGM LSZ3L LSZ4010
LSK4L-8C LSZ1KHC LSZ3L LSZ4014
LSK7L-8C LSZ1KHC LSZ3L LSZ4014
For low temperature replacement head and actuators add Bbetween the fifth
and sixth characters. Example: LSZ1KBHA. For fluorocarbon seals add C.
Example LSZ1KCHA.
Catalog
Listing* Operating Contact
On Switch Head Block Actuator
Nameplate Only† Only Only
LSL4M LSZ1L LSZ3M
LSL7M LSZ1L LSZ3M
LSM4N LSZ1M LSZ3M
LSM7N LSZ1M LSZ3M
LSN3K LSZ1N
LSN4L LSZ1N
LSN7L LSZ1N
LSP3K LSZ1P LSZ3K
LSP4L LSZ1P LSZ3L
LSP7L LSZ1P LSZ3L
LSR3K LSZ1R LSZ3K
LSR4L LSZ1R LSZ3L
LSR7L LSZ1R LSZ3L
LSV3K LSZ1V LSZ3K
LSV4L LSZ1V LSZ3L
LSV7L LSZ1V LSZ3L
LSW3K LSZ1W LSZ3K
LSW4L LSZ1W LSZ3L
LSW7L LSZ1W LSZ3L
REPLACEMENT PARTS FOR STAINLESS STEEL HDLS
Listing Operating Head Contact Block
LS2A3N LS2Z1A N/A
LS2A4K LS2Z1A LSZ3K
LS2A4L LS2Z1A LSZ3L
LS2D4K LS2Z1D LSZ3K
LS2D4L LS2Z1D LSZ3L
LS2E4K LS2Z1E LSZ3K
LS2E4L LS2Z1E LSZ3L
LS2F4K LS2Z1F LSZ3K
LS2F4L LS2Z1F LSZ3L
LS2H3K LS2Z1H LSZ3K
LS2H4K LS2Z1H LSZ3K
LS2H4L LS2Z1H LSZ3L
LS2M4N LS2Z1M LSZ3M
LS2N3K LS2Z1N LSZ3K
*Only partial listings are shown and necessary to determine replacement parts
catalog listing. The listings with -7A, -7M, -7N, -8A, -8B and -8C are complete
catalog listings.
For low temperature replacement heads add B. Example LSZ1AB. For fluoro-
carbon seal replacement heads add C. Example LSZ1AC.
Limit/ Enclosed
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
LSZ51 LSZ51A LSZ51C LSZ52 LSZ52A LSZ52C LSZ52J LSZ53D LSZ53S LSZ54 LSZ55C LSZ618 LSZ68
LSZ1KHC LSZ1M LSZ1N LSZ1R LSZ3A LSZ4001 LSZ7A1A LSZ7A6B LSZ1AB LSZ1H LSZ1JGA LSZ1JGN
LSZ1T LSZ1U LSZ3B LSZ3C LSZ3L LSZ3M LSZ4006M LSZ4014 LSZ51R LSZ51T LSZ52E LSZ53 LSZ53B
LSZ54N-C LSZ54P LSZ55 LSZ55B LSZ617 LSZ7D1A LSZ7P1A LSZ7R5A LSZ4009 LSZ7J1A-7N LSZ24N
LSYUB1A23 LS-20238 LSZ24L LS-10206 LSL7M-1P LSYMB4N-1A LS-21756 LS-20757 LSYMC6DF-1B LS-
20142 LSZ7A1A2 LS-20092 LSZ4006F LSYKB1A-8A LSZ7YEC1A LSZ4001Q LSZ4001PC LSQYJB1A346 LS-
20085 LSZ23KC LSQ2L4M321 LSZ7YKB1A-8C LS-20575 LSZ7YCC5A LSYUB1A13-2A LSYAC1EC LSZ26UB
LS-21083 LSZ21AC LS-21205 LS-10101 LSYJC1ADD-7N LSYPB7L3 LSYPB3K4 LSQYFB3K345 LS-20985
LSZ4001H LSYAC1ADD-4N LSZ4024 LSZ4001Y LSZ21AB LS-10841 LSYNC1E LSYKC7LR-8AFP LSYKC5KQ-
8BFP LS-20449 LSYJC7LR-7MFP LSZ7YUB6B LSZ26D LSZ7YWC1A LSYPB4L3