Limit and Enclosed Switches Rotary Actuated Switches HDLS Series Order guides below and on page A35 provide specification and pricing information for side and top rotary switches. Plug-in body style catalog listings consist of the complete plug-in base receptacle. Levers are ordered separately. See pages A37-A39 for lever selection. For rapid response - off the shelf service, all bold face listings are normally stocked items. PRELEADED OR CONNECTORIZED VERSIONS Refer to page A42. For low temperature, high temperature or preleading see page A42. Top Rotary ORDER GUIDE (Momentary action. UL listed, CSA certified, CE approved. Levers not included. Order separately pages A37-A39.) Catalog Listings Side Rotary Top Rotary Standard Low Differential 5 Pretravel Low Torque Low Differential Low Torque Plug-in 12N Conduit LSA1A LSP1A LSU1A LSR1A LSH1A LSB1A Plug-in 12N Conduit LSA1J LSU1J -- -- LSB1J LSA1E LSP1E -- LSR1E LSH1E -- 120 V Ind. lite Plug-In* 12N Conduit LSA5A LSP5A LSU5A LSR5A LSH5A LSB5A 240 V Ind. lite Plug-In Conduit LSA8A LSP8A LSU8A LSR8A LSH8A LSB8A 24 V LED lite 1.5mA max. Auto polarity Plug-in 12 N Conduit LSA9A LSP9A LSU9A LSR9A LSH9A LSB9A Non plug-in Conduit LSA3K LSP3K LSU3K LSR3K LSH3K LSB3K B Plug-in 34N Conduit LSA2B LSP2B LSU2B LSR2B LSH2B LSB2B B Plug-in 12N Conduit LSA6B LSP6B LSU6B LSR6B LSH6B LSB6B B 120 V Ind. lite Plug-in 34N Conduit LSA2R LSP2R LSU2R LSR2R LSH2R LSB2R B Non plug-in 34N Conduit LSA4L LSP4L LSU4L LSR4L LSH4L LSB4L B Non plug-in 12N Conduit Non plug-in 12N Conduit LSA7L LSP7L LSU7L LSR7L LSH7L LSB7L Circuitry Electrical Rating Silver contacts A Gold cross point contacts C Gold plated contacts C Silver contacts A* A* Body** Style High Overtravel 12N A* SPDT Double Break Silver contacts DPDT Double Break SPNC Direct Acting A 12N D *Use at voltage indicated for light. Wired to N.O. circuit. LSA3N LSR3N Upper temperature limit for lighted units is 200F (93C). LSB3N ** Plug-in listings include base receptacle. OPERATING CHARACTERISTICS Pretravel (degrees max.) Differential Travel (degrees max.) 15 9 5 15 9 25 SPDT 5 3 3 5 3 10 DPDT 7 4 4 7 4 12 60 66 70 60 66 110 0,45 Nm 4 in. lbs. 0,45 Nm 4 in. lbs. 0,45 Nm 4 in. lbs. 0,19 Nm 1.7 in. lbs. 0,19 Nm 1.7 in. lbs. 0,28 Nm 2.5 in. lbs. Overtravel (degrees min.) Operating Torque (max.) Operating Temperature Range*** NM JNewton meters 10F to 250F -12 to 121C 30F to 250F -1 to 121C ***Completely fluorocarbon-sealed switches are preferred for use in temperatures above 200F (93C). Refer to page A42. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A33 Limit/Enclosed Side Rotary ASSEMBLED CONDITIONS Catalog listings in order guide below are factory assembled with: 1 Shaft of side rotary heads facing front of switch (label side). 1 Head adjusted for both clockwise and counterclockwise operation. 1 Light on indicator versions wired to N.O. circuit. Refer to facing page to specify modifications to these assembled conditions. Limit and Enclosed Switches Rotary Actuated Switches HDLS Series ACTUATION DIRECTION (Drawings apply to listings on facing page only). CW & CCW (Normal) LEVERS Levers for rotary actuated switches are normally ordered as separate catalog listings. They also may be ordered by including a suffix to the switch catalog listing and adding the lever price. See pages A34-A39. CW Mod. 1 CCW Mod. 2 HEAD ORIENTATION Mod. 5 Mod. 4 Mod. 3 Front (Normal) SWITCHES FOR SPECIAL APPLICATIONS HDLS limit switches for special application needs are described on pages A42 and A43. They include: manifold mount, low temperature, complete fluorocarbon-sealed, gravity return, extra low torque and 20 Amp switches. Adapter plates for interchanging HDLS with LS/200LS limit switches are described on page A49. ELECTRICAL RATINGS 10 amps continuous carry (except for electrical rating ``C''). Circuits on any one pole must be the same polarity. AC Volts Pilot duty: 600 VAC, 720VA ASSEMBLY MODIFICATIONS How to order Momentary action rotary switches can be furnished in other than the normal assembled conditions described on the facing page. To specify modifications, add the number(s) shown below to the catalog listings. Prices are the same as their counterparts shown in the order guide. Modification number suffixes are: 1 Clockwise operation only 2 Counterclockwise operation only 3 Shaft to right of switch front 4 Shaft to left of switch front 5 Shaft to back of switch 7 Indicator light wired to N.C. circuit Examples: Catalog Listing LSA1A23 is an LSA1A switch adjusted for counterclockwise operation only. The operating shaft is to the right side of the switch when viewing it from the front (label side). No lever. Catalog Listing LSA8A7 is an LSA8A switch with the 240 volt indicator light wired to the N.C. circuit. No lever. Switches with assembly modifications are not normally stocked and may extend delivery leadtimes. Electical Rating Circuitry VAC Amps at 0.35 Power Factor Make Break A* Single-Pole Double-Throw 120 240 480 600 60 30 15 12 6 3 1.5 1.2 B Double-Pole Double-Throw 120 240 480 600 30 15 7.5 6 3 1.5 0.75 0.60 D Single-Pole Single-Throw Normally Closed 120 240 480 600 60 30 15 12 6 3 1.5 1.2 C** Single-Pole Double-Throw 250 VAC or 60 VDC, .050 amp max. DC Volts Pilot duty: 240 VDC, 30 watts Electrical Rating Circuitry VDC Make and Break Amps Inductive Resistive A* Single-Pole Double-Throw 120 240 0.25 0.15 0.8 0.4 B Double-Pole Double-Throw 120 240 0.25 0.15 0.8 0.4 D Single-Pole Single-Throw Normally Closed 30 120 4.3 1.1 4.3 1.1 C** Single-Pole Double-Throw 250 VAC or 60 VDC, .050 amp max. * For switches with indicator light, use only at voltage stated for indicator light. ** These switches have either gold plated or gold cross point contacts. Cross point contacts improve high reliability of contact make when particle contamination is a problem or low energy loads must be carried. A34 Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Limit and Enclosed Switches Rotary Actuated Switches HDLS Series ADDITIONAL CIRCUITRY/ACTION OPTIONS ASSEMBLY MODIFICATIONS Switches in the order guide, below, have the operating shaft facing front. If another orientation is desired, add a number from the drawing to the catalog listing. HEAD ORIENTATION (Drawing applies to this page only.) Mod. 5 To specify the indicator light wired to the N.C. circuit, add 7 to the catalog listing. Mod. 3 Front (Normal) Mod. 4 Example: Catalog Listing LSN5A37 is an LSN5A switch with the shaft facing right and the indicator light wired to the N.C. circuit. Circuitry Elec. Rating Page A23 Body** Style For low temperature, all Viton or preleaded versions see page A42. Maintained 360 Alternate 2 Position Action Standard Sequential (Pole 1 operates before Pole 2, either CW or CCW or both) CENTER NEUTRAL SEQUENCE LSN3K SPDT Double Break each direction Electrical rating B (2) SPDT Double Break with 10 between operation Electrical rating B A Plug-in 12N Conduit A* 120V Ind. Lite Plug-in 12N Conduit LSN5A A* 240V Ind. Lite Plug-in 12N Conduit LSN8A A SPDT Double Break Maintained DPDT Double Break Maintained Non plug-in Conduit 12N LSQ300 Center Neutral (Pole 1 operates CCW Pole 2 operates CW) LSN1A LSQ310 B Plug-in 34N Conduit LSN2B LSM2D LSL2C B Plug-in 12N Conduit LSN6B LSM6D LSL6C B Non plug-in 34N Conduit LSN4L LSM4N LSL4M B Non plug-in 12N Conduit LSN7L LSM7N LSL7M Non plug-in Conduit LSN3N D SP Normally Closed Direct Acting LSQ320 12 N * Use at voltage indicated for light. Wired to N.O. circuit. Upper temperature for lighted units is 200 F (93 C). ** Plug-in listings include base receptacle. Total travel is approximately 80 max. Maintained contact switch normally used with LSZ53 yoke actuator. OPERATING CHARACTERISTICS Pretravel (degrees max.) SPDT 65 Not Applicable Not Applicable Note: Mechanical trip before electrical trip DPDT 65 18 1st Pole 15 2nd Pole 10 additional (max.) SPDT 40 Not Applicable Not Applicable DPDT 40 10 For each pole -- 5 degrees Differential Travel (degrees max.) Overtravel (degrees min.) Operating Torque (max.) Nm J Newton meters Operating Temperature Range*** 20 57 48 0,45 Nm 4 in. lbs. 0,45 4 in. lbs. 0,45 4 in. lbs. 30F to 250F -1 to 121C 10F to 250F -12 to 121C *** Completely fluorocarbon-sealed switches are preferred for temperatures above 200F (93C). Refer to page A42. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A35 Limit/Enclosed ORDER GUIDE Maintained, center neutral, or sequential action. UL listed, CSA certified. Levers not included (see pages A36-A39). Lever ordering information is shown on pages A36-A39. Limit and Enclosed Switches Levers for Rotary Actuated Switches Levers for use with side or top rotary actuated switches are available in a wide choice of sizes and materials, as shown in the order guides on the following pages. Rollers may be on either side of the lever to best match the external actuating mechanism. They permit a wide range of cam tracking possibilities (see drawings below). LSZ51 standard rollers and LSZ55 offset roller levers have a fixed 1.5 inch (38,1 mm) radius. LSZ53 yoke roller levers are used with side rotary maintained switches, where a reciprocating actuator operates the switch in one direction and reverses it when moving in the other direction. LSZ52 adjustable length roller levers are universally adaptable to many application needs. LSZ54 rod levers may be formed by the user. The hub permits adjusting of lever length. Also available in flexible versions. LSZ61 is an adjustable loop lever. For lever order guides, refer to the following pages. CAM TRACKING Open mounted roller HDLS Series LSZ51 Type LSZ55 Type LSZ53 Type LSZ52 Type LSZ54 Type LSZ61 Type LSZ51 TYPE LEVERS LSZ52 TYPE LEVER Close mounted roller LSZ54 TYPE LEVER LSZ55 TYPE LEVERS Open mounted roller Close mounted roller NOTE: Shaft dia. is .29 in. A36 Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Limit and Enclosed Switches Levers for Rotary Actuated Switches HDLS Series Rollers may be mounted on the front or back side of the lever. (See below). FRONT MOUNT BACK MOUNT Teller Tab Limit/Enclosed Teller tab assures proper torque. When it cannot be moved, the lever is tight enough to prevent slippage. Levers shown in the order guides are furnished with cap screws which accommodate a 964-inch allen wrench. ORDER GUIDE Radius (in.) Roller Mounted On This Side Of Lever Dia. in. Width in. Material LSZ51 Series Std. Roller Lever 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 Front Front Back Back Front Front Back Back Back Back Front Front -- .75 .75 .75 .75 1.0 1.5 1.0 .75 .75 .75 .75 1.59 -- .25 .25 .25 .25 .50 .25 .50 .25 1.30 .375 .50 .25 -- Nylon Steel Nylon Steel Nylon Nylon Nylon Ball Bearing Nylon Stainless Nylon Nylon Less Roller LSZ51A LSZ51B LSZ51C LSZ51D LSZ51F LSZ51G LSZ51J LSZ51L LSZ51M LSZ51T LSZ51P LSZ51R LSZ51 LSZ53 Series Yoke 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 Front-Back Front-Back Front-Front Back-Front Back-Back Back-Back Back-Front Back-Front -- .75 .75 .75 .75 .75 .75 .75 .75 -- .25 .25 .25 .25 .25 .25 .25 1.25 -- Nylon Steel Steel Nylon Nylon Steel Steel Nylon Less Rollers LSZ53A LSZ53B LSZ53D LSZ53E LSZ53S LSZ53P LSZ53U LSZ53M LSZ53 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 -- Back Back Front Front Front Front Front -- .75 .75 .75 .75 .75 1.5 1.0 -- .25 .25 .25 .25 .50 .25 .50 Less Roller Nylon Steel Nylon Steel Nylon Nylon Nylon LSZ55 LSZ55A LSZ55B LSZ55C LSZ55D LSZ55E LSZ55K LSZ55F -- 6.0 -- Stainless (spokes replaceable) LSZ69CA Type Catalog Listings Back view of LSZ53E LSZ55 Series Offset LSZ69 Series* *For use with LSQ300 Series. Hub is aluminum. See page A59 for dimensions. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A37 Limit and Enclosed Switches Levers for Rotary Actuated Switches METRIC CONVERSION .25 in. .5 in. .625 in. .75 in. 1.0 in. 1.5 in. 2.0 in. 2.5 in. 3.0 in. 4.8 in. 5.0 in. 6.0 in. 12.0 in. J J J J J J J J J J J J J 6,35 mm 12,7 mm 15,9 mm 19,1 mm 25,4 mm 38,1 mm 50,8 mm 63,5 mm 76,2 mm 122 mm 127 mm 152 mm 305 mm HDLS Series LOW TORQUE APPLICATION CONSIDERATION When heavier levers (such as LSZ52 series and LSZ54 series, below), are used with low torque LSH, LSR, LSS and LST switches, it is desirable to mount the switch with the lever down. In this way, gravity will assist in restoring levers to the free position. Conversely, when these switches are mounted with the lever upright, gravity tends to work to prevent lever return after switching actuation. By counterbalancing the lever or adding an auxiliary extension spring, this problem may be overcome. Contact the 800 number for application assistance. ORDER GUIDE Radius (in.) Roller Mounted On This Side Of Lever Dia. in. Width in. LSZ52 Series Adjustable Radius 1.5-3.5 1.5-3.5 1.5-3.5 1.5-3.5 1.5-3.5 1.5-3.5 1.5-3.5 1.5-3.5 1.5-3.5 1.5-3.5 Back Back Front Front Front Front Front Front Front Front .75 .75 .75 .75 .75 1.0 1.5 .75 2.0 .75 .25 .25 .25 .25 1.30 .5 .25 .25 .25 .5 Nylon Steel Nylon Steel Nylon Nylon Nylon Ball Bearing Nylon Nylon Less Roller Hub Only LSZ68 Series 12.0 -- .25 -- Spring/Rod 16.0 -- .25 -- Delrin Rod w/Spring Delrin Rod w/Spring LSZ54 Series Rod 5.5 13.0 20.0 12.0 4.8 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- LSZ61 Series Flexible Loop 6N Flexible Loop/Cap Screw 9.5N Flexible Loop/Cap Screw (measured from center line of shaft hole to tip of actuator) LSZ60 Series One Way Roller Lever See page A60 for dimensions A38 Front Front .75 .75 .25 .25 Material Catalog Listingss tings Type LSZ52A LSZ52B LSZ52C LSZ52D LSZ52E LSZ52J LSZ52K LSZ52L LSZ52M LSZ52N LSZ52 LSZ54 LSZ68 LSZ617 Aluminum Stainless Steel Delrin Rod Spring Wire Flexible Cable Hub Only LSZ54M LSZ54N LSZ54P LSZ54R LSZ54V* LSZ54 Nylatron Hub Only LSZ61 LSZ618 LSZ54 Nylon Steel LSZ60A LSZ60B *Hub not available separately. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Limit and Enclosed Switches Levers for Rotary Actuated Switches HDLS Series FIXED LENGTH LEVERS ORDER GUIDE For a complete listing add your choice of roller suffix Fixed Length Levers LSZ65 Series Lever Length (in.) LSZ65A LSZ65B LSZ65L LSZ65C LSZ65D LSZ65E LSZ65F LSZ65G LSZ65H LSZ65J LSZ65K Roller Suffix Dia. in. Width in. Material A B .75 .75 .25 .25 Nylon Steel C D E F .75 .75 1.00 1.50 .50 1.30 .50 .25 Nylon Nylon Nylon Nylon Example: LSZ65AB is a .88N long lever with a steel .75N diameter, .25N wide roller. Limit/Enclosed .88 1.38 1.25 1.50 1.75 2.00 2.50 3.00 4.00 5.00 6.00 Lever Listing RUBBER ROLLER LEVERS Ideal for elevator or conveyor applications requiring quiet operation or protection of delicate surfaces. ORDER GUIDE Radius (in.) Roller Mounted On This Side Of Lever Dia. in. Width in. Material Catalog Listing LSZ51 Series Std. Roller Lever 1.5 1.5 Front Front 1.6 2.0 .5 .5 Rubber Rubber LSZ51W LSZ51Y LSZ55 Series Offset 1.5 1.5 Front Front 1.6 2.0 .50 .50 Rubber Rubber LSZ55W LSZ55Y LSZ52 Series Adjustable Radius 1.5 to 3.5 1.5 to 3.5 Front Front 1.6 2.0 .50 .50 Rubber Rubber LSZ52W LSZ52Y LSZ67 Series Conveyor Roller -- -- 1.5 3.8 Plastic LSZ67AA Type Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A39 Limit and Enclosed Switches Plunger Actuated Switches HDLS Series ASSEMBLED CONDITIONS Catalog listings in order guide below are factory assembled with: 1 Side plungers facing front (label side) of switch. Rollers on side plungers are in horizontal position. ORDER GUIDE Momentary action, except for maintained contact LSG version. UL listed, CSA certified. 1 Roller on top plungers are parallel to mounting surface. 1 Lights on indicator versions are wired to N.O. circuit. Circuitry For Maintained Plunger Refer to facing page to specify modifications to these assembled conditions. For low temperature, high temperature or preleaded versions see page A42. SPDT Double Break (Electrical rating A) DPDT Double Break (Electrical rating B) Circuits on any one pole must be the same polarity. Catalog Listings Top Plungers Side Plungers Catalog listings in this chart are complete switches. Circuitry Maintained Elec. Rating Page A34 Silver contacts A Plain Roller Adjustable Plain Roller Adjustable (Circuitry Shown Above) Plug-in 12N Conduit LSC1A LSD1A LSV1A LSE1A LSF1A LSW1A LSG1A Plug-in Conduit LSC1J LSD1J LSV1J LSE1J LSF1J LSW1J -- -- LSD1E -- -- LSF1E LSW1E -- Body** Style Gold cross pt. C Gold plated C Silver contacts A* 120 V. Ind. Lite Plug-in 12N Conduit* LSC5A LSD5A LSV5A LSE5A LSF5A LSW5A LSG5A A* 240 V. Ind. Lite Plug-in 12N Conduit* LSC8A LSD8A LSV8A LSE8A LSF8A LSW8A LSG8A Non plug-in Conduit LSC3K LSD3K LSV3K LSE3K LSF3K LSW3K LSG3K 12N SPDT Double Break A Silver contacts B Plug-in 34N Conduit LSC2B LSD2B LSV2B LSE2B LSF2B LSW2B LSG2B B 120 V Ind. Lite Plug-in 34N Conduit LSC2R LSD2R LSV2R LSE2R LSF2R LSW2R LSG2R Plug-in Conduit LSC6B LSD6B LSV6B LSE6B LSF6B LSW6B LSG6B Non plug-in Conduit LSC4L LSD4L LSV4L LSE4L LSF4L LSW4L LSG4L Non plug-in Conduit Non plug-in 12N Conduit LSC7L LSD7L LSV7L LSE7L LSF7L LSW7L LSG7L -- -- -- LSE3N LSF3N LSW3N LSG3N B B DPDT Double Break B D SPNC Direct Acting 12N 12N 34N 12N *Use at voltage indicated for light. Upper operating temperature limit for lighted units is 200F. Wired to N.O. circuit. ** Plug-in listings include base receptacle. OPERATING CHARACTERISTICS mm Pretravel (in. max.) 1,78 .070 1,78 .070 1,78 .070 2,54 .100 2,54 .100 2,54 .100 4,32 .170 SPDT 0,38 .015 0,38 .015 0,38 .015 0,64 .025 0,64 .025 0,64 .025 2,29 .090 DPDT 0,51 .020 0,51 .020 0,51 .020 0,89 .035 0,89 .035 0,89 .035 2,29 .090 mm Overtravel (in. min.) 4,83 .190 4,83 .190 4,83 .190 4,83 .190 4,83 .190 4,83 .190 2,0 .080 Newton Operating Force (lb. max.) 17,8 4 17,8 4 17,8 4 26,7 6 26,7 6 26,7 6 44,5 10 Differential mm Travel (in. max.) Operating Point mm (in.) Operating Temperature Range A40 45,8 0,76 55,9 1,02 53,0 to 59,3 33,0 0,76 44,1 1,02 41,0 to 47,4 37,6 0,76 1.805 .030 2.200 .040 2.085 to 2.335 1.300 .030 1.735 .040 1.615 to 1.865 1.480 .030 10F to 200F -12 to 93C 10F to 200F -12 to 93C 10F to 200F -12 to 93C Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 30F to 200F -1 to 93C Limit and Enclosed Switches Plunger Actuated Switches/Assembly Modifications HDLS Series ASSEMBLY MODIFICATIONS How to order To specify other than the normal assembled conditions described on facing page, add the following modification numbers to the catalog listing in the plunger switch order guide. Mod. 3 Side plunger to right of switch front 4 Side plunger to left of switch front 5 Side plunger to back of switch 6 Roller on top plungers perpendicular to mounting surface 7 Light on indicator versions wired to N.C. circuit 8 Roller on side plungers in vertical position. Example: LSF1A3 is an LSF1A with the side roller plunger to the right side. Wobble Actuated Switches Limit/Enclosed Wobble actuated switches have flexible levers which may be operated with any movement, except direct pull. ORDER GUIDE Momentary action. UL listed, CSA certified Catalog Listings Catalog listings in this chart are complete switches. Lever lengths measured from top mounting hole Circuitry Elec. Rating Page A34 Body** Style 5.5N 13N 5.5N 5.5N 5.5N Delrin Rod Spring Wire Cat*** Whisker Cable Coil Spring LSJ1A-7M LSK1A-8A LSJ1A-7N LSK1A-8C Silver contacts A Plug-in 12N Conduit LSJ1A-7A Gold cross point C LSJ1J-7M LSK1J-8A LSJ1J-7N LSK1J-8C C Plug-in 12N Conduit LSJ1J-7A Gold plated contacts -- LSJ1E-7M -- -- -- A* 120 V. Ind. Lite Plug-in 12N Conduit* LSJ5A-7A LSJ5A-7M LSK5A-8A LSJ5A-7N LSK5A-8C A* 240 V. Ind. Lite Plug-in 12N Conduit* LSJ8A-7A LSJ8A-7M LSK8A-8A LSJ8A-7N LSK8A-8C A Non plug-in 12N Conduit LSJ3K-7A LSJ3K-7M LSK3K-8A LSJ3K-7N LSK3K-8C B Plug-in 34N Conduit LSJ2B-7A LSJ2B-7M LSK2B-8A LSJ2B-7N LSK2B-8C 120 V Ind. Lite Plug-In Conduit LSJ2R-7A LSJ2R-7M LSK2R-8A LSJ2R-7N LSK2R-8C Plug-in Conduit LSJ6B-7A LSJ6B-7M LSK6B-8A LSJ6B-7N LSK6B-8C Non plug-in Conduit LSJ4L-7A LSJ4L-7M LSK4L-8A LSJ4L-7N LSK4L-8C Non plug-in Conduit LSJ7L-7A LSJ7L-7M LSK7L-8A LSJ7L-7N LSK7L-8C mm Pretravel (approx. in. radius) 25,4 1 102 4 51 2 38 1.5 51 2 Newton Operating Force (oz. max.) 2,78 10 1,39 5 1,39 5 1,95 7 1,95 7 Silver contacts SPDT Double Break Silver contacts B 34N B B DPDT Double Break B 12N 34N 12N OPERATING CHARACTERISTICS Operating Temperature Range * Use at voltage indicated for light. Upper operating temperature limit for lighted units is 200F. 10F to 200F ** Plug-in listings include base receptacle. 12 to 93C *** These cat whiskers have 512 inch long levers. To specify 712 inch length, substitute -8B for -8A. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A41 Limit and Enclosed Switches Modification and Replacement Parts Non plug-in type HDLS Series PLUG IN RECEPTACLES Plug-in type Type Catalog Listing Single-Pole LSZ4001 Double-Pole 34 in. Conduit LSZ4002 Double-Pole 12 in. Conduit LSZ4006 Single-Pole Manifold Mount LSZ4015 Double-Pole Manifold Mount LSZ4016 Catalog Listing Type Adapts 200LS series mounting to accept HDLS LSZ4003 Adapts 300LS series mounting to accept HDLS LSZ4004 INDICATOR LIGHTS/SEAL RING REPLACEMENT WOBBLE ACTUATORS Type Catalog Listing 120V LSZ4007 240V LSZ4008 ADJUSTING TOOL KIT This tool kit is used if readjustment of switches is necessary when heads and/or contact blocks are replaced. Catalog Listing Catalog Listing LSZ4005 REPLACEMENT LEVERS To order replacement levers, specify the same part number that is metal stamped on either the lever or lever hub. For a complete list of HDLS replacment parts, refer to the charts on the following pages. Delrin Rod LSZ4009 *512 inch long. For 712N Spring Wire Cable Cat Whisker Coil Spring LSZ4010 LSZ4011 LSZ4012* LSZ4014 length, order LSZ4013. MICRO SWITCH conduit sealing packets can be used with limit or enclosed switches. This includes the HDLS, Compact LS, ML, E6, V6, BAF1 or OP series switches. The conduit sealing packets are not suitable for use with explosion-proof switches. CONDUIT SEALING PACKETS Catalog Listing Packet Cable O.D. Inches 2PA6 .400N - .435N 2PA16 .435N - .470N 2PA1 .530N - .570N LIQUID TIGHT CONDUIT FITTING 2PA17 .170" - .470" 1/2 NPT 2PA19 .450" - .709" 3/4 NPT Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A49 Limit/Enclosed ADAPTER PLATES These adapter plates enable HDLS plug-in switches to retrofit 200LS series (singlepole) and 300LS series (double-pole) plugin switches. Limit and Enclosed Switches Replacement Parts HDLS Series For low temperature or high temperature options, refer to example in LSA1A block. PLUG-IN TYPE 1 2 3 4 5 Catalog Listing* On Switch Nameplate Complete Plug-in Unit Less Base Receptacle Plug-in Base Receptacle Only Operating Head Only Contact Block Only Actuator Only Std. LSA1A Low Temp. LSYAB1A High Temp. LSYAC1A LSZ7A1A LSZ7YAB1A LSZ7YAC1A LSZ4001 LSZ4001 LSZ4001 LSZ1A LSZ1AB LSZ1AC LSZ3A LSZ3A LSZ3A LSA5A LSZ7A5A LSZ4001 LSZ1A LSZ3A LSA8A LSZ7A8A LSZ4001 LSZ1A LSZ3A LSA1J LSZ7A1J LSZ4001 LSZ1A LSZ3J LSA2B LSZ7A2B LSZ4002 LSZ1A LSZ3B LSA6B LSZ7A6B LSZ4006 LSZ1A LSZ3B LSB1A LSZ7B1A LSZ4001 LSZ1B LSZ3A LSB1J LSZ7B1J LSZ4001 LSZ1B LSZ3J LSB5A LSZ7B5A LSZ4001 LSZ1B LSZ3A LSB8A LSZ7B8A LSZ4001 LSZ1B LSZ3A LSB2B LSZ7B2B LSZ4002 LSZ1B LSZ3B LSB6B LSZ7B6B LSZ4006 LSZ1B LSZ3B LSC1A LSZ7C1A LSZ4001 LSZ1C LSZ3A LSC1J LSZ7C3J LSZ4001 LSZ1C LSZ3J LSC5A LSZ7C5A LSZ4001 LSZ1C LSZ3A LSC8A LSZ7C8A LSZ4001 LSZ1C LSZ3A LSC2B LSZ7C2B LSZ4002 LSZ1C LSZ3B LSC6B LSZ7C6B LSZ4006 LSZ1C LSZ3B LSD1A LSZ7D1A LSZ4001 LSZ1D LSZ3A LSD1J LSZ7D1J LSZ4001 LSZ1D LSZ3J LSD2B LSZ7D2B LSZ4002 LSZ1D LSZ3B LSD5A LSZ7D5A LSZ4001 LSZ1D LSZ3A LSD8A LSZ7D8A LSZ4001 LSZ1D LSZ3A LSD6B LSZ7D6B LSZ4006 LSZ1D LSZ3B LSE1A LSZ7E1A LSZ4001 LSZ1E LSZ3A *Only partial listings are shown and necessary to determine replacement parts catalog listing. The listings with -7A, -7M, -7N, -8A, -8B and -8C are complete catalog listings. A50 Note: Complete units consist of Columns 1 and 2. For low temperature replacement heads add B. Example LSZ1AB. For fluorocarbon seal replacement heads add C. Example LSZ1AC. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Limit and Enclosed Switches Replacement Parts PLUG-IN TYPE (Continued) 1 HDLS Series 2 3 4 5 Actuator Only Complete Plug-in Unit Less Base Receptacle Plug-in Base Receptacle Only Operating Head Only Contact Block Only LSE1J LSZ7E1J LSZ4001 LSZ1E LSZ3J LSE2B LSZ7E2B LSZ4002 LSZ1E LSZ3B LSE5A LSZ7E5A LSZ4001 LSZ1E LSZ3A LSE8A LSZ7E8A LSZ4001 LSZ1E LSZ3A LSE6B LSZ7E6B LSZ4006 LSZ1E LSZ3B LSF1A LSZ7F1A LSZ4001 LSZ1F LSZ3A LSF1J LSZ7F1J LSZ4001 LSZ1F LSZ3J LSF2B LSZ7F2B LSZ4002 LSZ1F LSZ3B LSF5A LSZ7F5A LSZ4001 LSZ1F LSZ3A LSF8A LSZ7F8A LSZ4001 LSZ1F LSZ3A LSF6B LSZ7F6B LSZ4006 LSZ1F LSZ3B LSG1A LSZ7G1A LSZ4001 LSZ1G LSG5A LSZ7G5A LSZ4001 LSZ1G LSG8A LSZ7G8A LSZ4001 LSZ1G LSG2B LSZ7G2B LSZ4002 LSZ1G LSG6B LSZ7G6B LSZ4006 LSZ1G LSH1A LSZ7H1A LSZ4001 LSZ1H LSZ3A LSH2B LSZ7H2B LSZ4002 LSZ1H LSZ3B LSH6B LSZ7H6B LSZ4006 LSZ1H LSZ3B LSH5A LSZ7H5A LSZ4001 LSZ1H LSZ3A LSH8A LSZ7H8A LSZ4001 LSZ1H LSZ3A LSJ1A-7A LSZ7J1A-7A LSZ4001 LSZ1JGA** LSZ3A LSZ4009 LSJ1A-7M LSZ7J1A-7M LSZ4001 LSZ1JGM** LSZ3A LSZ4010 *Only partial listings are shown and necessary to determine replacement parts catalog listing. The listings with -7A, -7M, -7N, -8A, -8B and -8C are complete catalog listings. **Includes actuator Note: Complete units consist of Columns 1 and 2. Limit/Enclosed Catalog Listing* On Switch Nameplate For low temperature replacement heads add B. Example LSZ1AB. For fluorocarbon seal replacement heads add C. Example LSZ1AC. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A51 Limit and Enclosed Switches Replacement Parts PLUG-IN TYPE (Continued) 1 2 3 4 5 Catalog Listing* On Switch Nameplate Complete Plug-in Unit Less Base Receptacle Plug-in Base Receptacle Only Operating Head and Actuator Contact Block Only Actuator Only LSJ5A-7M LSZ7J5A-7M LSZ4001 LSZ1JGM LSZ3A LSZ4010 LSJ8A-7M LSZ7J8A-7M LSZ4001 LSZ1JGM LSZ3A LSZ4010 LSJ2B-7A LSZ7J2B-7A LSZ4002 LSZ1JGM LSZ3B LSZ4009 LSJ2B-7M LSZ7J2B-7M LSZ4002 LSZ1JGM LSZ3B LSZ4010 LSJ6B-7M LSZ7J6B-7M LSZ4006 LSZ1JGM LSZ3B LSZ4010 LSJ5A-7A LSZ7J5A-7A LSZ4001 LSZ1JGA LSZ3A LSZ4009 LSJ8A-7A LSZ7J8A-7A LSZ4001 LSZ1JGA LSZ3A LSZ4009 LSJ6B-7A LSZ7J6B-7A LSZ4006 LSZ1JGA LSZ3B LSZ4009 LSJ1A-7N LSZJ1A-7N LSZ4001 LSZ1JGN LSZ3A LSZ4011 LSJ1J-7N LSZ7J1J-7N LSZ4001 LSZ1JGN LSZ3J LSZ4011 LSJ5A-7N LSZ7J5A-7N LSZ4001 LSZ1JGN LSZ3A LSZ4011 LSJ8A-7N LSZ7J8A-7N LSZ4001 LSZ1JGN LSZ3A LSZ4011 LSJ2B-7N LSZ7J2B-7N LSZ4002 LSZ1JGN LSZ3B LSZ4011 LSJ6B-7N LSZ7J6B-7N LSZ4006 LSZ1JGN LSZ3B LSZ4011 LSK1A-8A LSZ7K1A-8A LSZ4001 LSZ1KHA LSZ3A LSZ4012 LSK1J-8A LSZ7K1J-8A LSZ4001 LSZ1KHA LSZ3J LSZ4012 LSK2B-8A LSZ7K2B-8A LSZ4002 LSZ1KHA LSZ3B LSZ4012 LSK5A-8A LSZ7K5A-8A LSZ4001 LSZ1KHA LSZ3A LSZ4012 LSK8A-8A LSZ7K8A-8A LSZ4001 LSZ1KHA LSZ3A LSZ4012 LSK6B-8A LSZ7K6B-8A LSZ4006 LSZ1KHA LSZ3B LSZ4012 LSK1A-8C LSZ7K1A-8C LSZ4001 LSZ1KHC LSZ3A LSZ4014 LSK1A-8B LSZ7K1A-8B LSZ4001 LSZ1KHB LSZ3A LSZ4013 LSK5A-8C LSZ7K5A-8C LSZ4001 LSZ1KHC LSZ3A LSZ4014 LSK8A-8C LSZ7K8A-8C LSZ4001 LSZ1KHC LSZ3A LSZ4014 LSK2B-8C LSZ7K2B-8C LSZ4002 LSZ1KHC LSZ3B LSZ4014 LSK6B-8C LSZ7K6B-8C LSZ4006 LSZ1KHC LSZ3B LSZ4014 *Only partial listings are shown and necessary to determine replacement parts catalog listing. The listings with -7A, -7M, -7N, -8A, -8B and -8C are complete catalog listings. A52 HDLS Series Note: Complete units consist of Columns 1 and 2. For low temperature replacement head and actuators add B between the fifth and sixth characters. Example: LSZ1KBHA. For fluorocarbon seals add C. Example LSZ1KCHA. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Limit and Enclosed Switches Replacement Parts PLUG-IN TYPE (Continued) 1 HDLS Series 2 3 4 5 Actuator Only Complete Plug-in Unit Less Base Receptacle Plug-in Base Receptacle Only Operating Head Only Contact Block Only LSL2C LSZ7L2C LSZ4002 LSZ1L LSZ3C LSL6C LSZ7L6C LSZ4006 LSZ1L LSZ3C LSM2D LSZ7M2D LSZ4002 LSZ1M LSZ3C LSM6D LSZ7M6D LSZ4006 LSZ1M LSZ3C LSN1A LSZ7N1A LSZ4001 LSZ1N LSN2B LSZ7N2B LSZ4002 LSZ1N LSN5A LSZ7N5A LSZ4001 LSZ1N LSN8A LSZ7N8A LSZ4001 LSZ1N LSN6B LSZ7N6B LSZ4006 LSZ1N LSP1A LSZ7P1A LSZ4001 LSZ1P LSZ3A LSP1J LSZ7P1J LSZ4001 LSZ1P LSZ3J LSP2B LSZ7P2B LSZ4002 LSZ1P LSZ3B LSP5A LSZ7P5A LSZ4001 LSZ1P LSZ3A LSP8A LSZ7P8A LSZ4001 LSZ1P LSZ3A LSP6B LSZ7P6B LSZ4006 LSZ1P LSZ3B LSR1A LSZ7R1A LSZ4001 LSZ1R LSZ3A LSR2B LSZ7R2B LSZ4002 LSZ1R LSZ3B LSR6B LSZ7R6B LSZ4006 LSZ1R LSZ3B LSR5A LSZ7R5A LSZ4001 LSZ1R LSZ3A *Only partial listings are shown and necessary to determine replacement parts catalog listing. The listings with -7A, -7M, -7N, -8A, -8B and -8C are complete catalog listings. Note: Complete units consist of Columns 1 and 2. Limit/Enclosed Catalog Listing* On Switch Nameplate For low temperature replacement heads add B. Example LSZ1AB. For fluorocarbon seal replacement heads add C. Example LSZ1AC. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A53 Limit and Enclosed Switches Replacement Parts PLUG-IN TYPE (Continued) 1 HDLS Series 2 3 4 5 Actuator Only Catalog Listing* On Switch Nameplate Complete Plug-in Unit Less Base Receptacle Plug-in Base Receptacle Only Operating Head Only Contact Block Only LSR8A LSZ7R8A LSZ4001 LSZ1R LSZ3A LSS1H LSZ7S1H LSZ4001 LSZ1S LSZ3H LSU1A LSZ7U1A LSZ4001 LSZ1U LSZ3A LST1H LSZ7T1H LSZ4001 LSZ1T LSZ3H LSU5A LSZ7U5A LSZ4001 LSZ1U LSZ3A LSV1A LSZ7V1A LSZ4001 LSZ1V LSZ3A LSV1J LSZ7V1J LSZ4001 LSZ1V LSZ3J LSV5A LSZ7V5A LSZ4001 LSZ1V LSZ3A LSV8A LSZ7V8A LSZ4001 LSZ1V LSZ3A LSV2B LSZ7V2B LSZ4002 LSZ1V LSZ3B LSV6B LSZ7V6B LSZ4006 LSZ1V LSZ3B LSW1A LSZ7W1A LSZ4001 LSZ1W LSZ3A LSW1J LSZ7W1J LSZ4001 LSZ1W LSZ3J LSW5A LSZ7W5A LSZ4001 LSZ1W LSZ3A LSW8A LSZ7W8A LSZ4001 LSZ1W LSZ3A LSW2B LSZ7W2B LSZ4002 LSZ1W LSZ3B LSW6B LSZ7W6B LSZ4006 LSZ1W LSZ3B NON PLUG-IN TYPE (These parts will not form a complete switch) Catalog Listing* On Switch Nameplate Operating Head Only Contact Block Only Catalog Listing* On Switch Nameplate Operating Head and Actuator Contact Block Only Actuator Only LSA3K LSZ1A LSZ3K LSJ7L-7A LSZ1JGA LSZ3L LSZ4009 LSA4L LSZ1A LSZ3L LSJ7L-7M LSZ1JGM LSZ3L LSZ4010 LSA7L LSZ1A LSZ3L LSJ4L-7N LSZ1JGN LSZ3L LSZ4011 LSB3K LSZ1B LSZ3K LSJ7L-7N LSZ1JGN LSZ3L LSZ4011 LSB4L LSZ1B LSZ3L LSK3K-8A LSZ1KHA LSZ3K LSZ4012 LSB7L LSZ1B LSZ3L LSK4L-8A LSZ1KHA LSZ3L LSZ4012 LSC3K LSZ1C LSZ3K LSK7L-8A LSZ1KHA LSZ3L LSZ4012 LSC4L LSZ1C LSZ3L LSK3K-8C LSZ1KHC LSZ3K LSZ4014 *Only partial listings are shown and necessary to determine replacement parts catalog listing. The listings with -7A, -7M, -7N, -8A, -8B and -8C are complete catalog listings. A54 Actuator Only Note: Complete units consist of Columns 1 and 2. For low temperature replacement head and actuators add B between the fifth and sixth characters. Example LSZ1KBHA. For fluorocarbon seals add C. Example LSZ1KCHA. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Limit and Enclosed Switches Replacement Parts HDLS Series NON PLUG-IN TYPE Catalog Listing* On Switch Nameplate Operating Head Only Contact Block Only Actuator Only Catalog Listing* On Switch Nameplate Operating Head Only Contact Block Only LSZ3M LSC7L LSZ1C LSZ3L LSL4M LSZ1L LSD3K LSZ1D LSZ3K LSL7M LSZ1L LSZ3M LSD4L LSZ1D LSZ3L LSM4N LSZ1M LSZ3M LSZ3M LSZ1D LSZ3L LSM7N LSZ1M LSZ1E LSZ3K LSN3K LSZ1N LSE4L LSZ1E LSZ3L LSN4L LSZ1N LSE7L LSZ1E LSZ3L LSN7L LSZ1N LSF3K LSZ1F LSZ3K LSP3K LSZ1P LSZ3K LSF4L LSZ1F LSZ3L LSP4L LSZ1P LSZ3L LSF7L LSZ1F LSZ3L LSP7L LSZ1P LSZ3L LSG3K LSZ1G LSR3K LSZ1R LSZ3K LSG4L LSZ1G LSR4L LSZ1R LSZ3L LSG7L LSZ1G LSR7L LSZ1R LSZ3L LSH3K LSZ1H LSZ3K LSV3K LSZ1V LSZ3K LSH4L LSZ1H LSZ3L LSV4L LSZ1V LSZ3L LSH7L LSZ1H LSZ3L LSV7L LSZ1V LSZ3L LSW3K LSZ1W LSZ3K LSW4L LSZ1W LSZ3L LSW7L LSZ1W LSZ3L Limit/Enclosed LSD7L LSE3K Actuator Only Catalog Listing* On Switch Nameplate Operating Head and Actuator Contact Block Only Actuator Only LSJ3K-7A LSZ1JGA LSZ3K LSZ4009 LSJ3K-7M LSZ1JGM LSZ3K LSZ4010 Listing Operating Head LSJ3K-7N LSZ1JGN LSZ3K LSZ4011 LS2A3N LS2Z1A N/A LSJ4L-7A LSZ1JGA LSZ3L LSZ4009 LS2A4K LS2Z1A LSZ3K REPLACEMENT PARTS FOR STAINLESS STEEL HDLS Contact Block LSJ4L-7M LSZ1JGM LSZ3L LSZ4010 LS2A4L LS2Z1A LSZ3L LSK4L-8C LSZ1KHC LSZ3L LSZ4014 LS2D4K LS2Z1D LSZ3K LSK7L-8C LSZ1KHC LSZ3L LSZ4014 For low temperature replacement head and actuators add B between the fifth and sixth characters. Example: LSZ1KBHA. For fluorocarbon seals add C. Example LSZ1KCHA. LS2D4L LS2Z1D LSZ3L LS2E4K LS2Z1E LSZ3K LS2E4L LS2Z1E LSZ3L LS2F4K LS2Z1F LSZ3K LS2F4L LS2Z1F LSZ3L LS2H3K LS2Z1H LSZ3K LS2H4K LS2Z1H LSZ3K LS2H4L LS2Z1H LSZ3L LS2M4N LS2Z1M LSZ3M LS2N3K LS2Z1N LSZ3K * Only partial listings are shown and necessary to determine replacement parts catalog listing. The listings with -7A, -7M, -7N, -8A, -8B and -8C are complete catalog listings. For low temperature replacement heads add B. Example LSZ1AB. For fluorocarbon seal replacement heads add C. Example LSZ1AC. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada A55 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: LSZ51 LSZ51A LSZ51C LSZ52 LSZ52A LSZ52C LSZ52J LSZ53D LSZ53S LSZ54 LSZ55C LSZ618 LSZ68 LSZ1KHC LSZ1M LSZ1N LSZ1R LSZ3A LSZ4001 LSZ7A1A LSZ7A6B LSZ1AB LSZ1H LSZ1JGA LSZ1JGN LSZ1T LSZ1U LSZ3B LSZ3C LSZ3L LSZ3M LSZ4006M LSZ4014 LSZ51R LSZ51T LSZ52E LSZ53 LSZ53B LSZ54N-C LSZ54P LSZ55 LSZ55B LSZ617 LSZ7D1A LSZ7P1A LSZ7R5A LSZ4009 LSZ7J1A-7N LSZ24N LSYUB1A23 LS-20238 LSZ24L LS-10206 LSL7M-1P LSYMB4N-1A LS-21756 LS-20757 LSYMC6DF-1B LS20142 LSZ7A1A2 LS-20092 LSZ4006F LSYKB1A-8A LSZ7YEC1A LSZ4001Q LSZ4001PC LSQYJB1A346 LS20085 LSZ23KC LSQ2L4M321 LSZ7YKB1A-8C LS-20575 LSZ7YCC5A LSYUB1A13-2A LSYAC1EC LSZ26UB LS-21083 LSZ21AC LS-21205 LS-10101 LSYJC1ADD-7N LSYPB7L3 LSYPB3K4 LSQYFB3K345 LS-20985 LSZ4001H LSYAC1ADD-4N LSZ4024 LSZ4001Y LSZ21AB LS-10841 LSYNC1E LSYKC7LR-8AFP LSYKC5KQ8BFP LS-20449 LSYJC7LR-7MFP LSZ7YUB6B LSZ26D LSZ7YWC1A LSYPB4L3