2.5 X 7.4 mm RECTANGULAR SOLID STATE LAMPS HIGH EFFICIENCY RED HLMP- 0300/1 YELLOW HLMP- 0400/1 HIGH EFFICIENCY GREEN HLMP- 0503/4 PACKAGE DIMENSIONS FEATURES * Wide viewing angle * Solid state reliability .315 (8.00) .290 (7.37) 1.00 (25.4) MIN. * Perfect for panel indicators CATHODE .050 (1.27) NOMINAL DESCRIPTION ANODE .295 (7.49) .275 (6.99) .100 (2.54) NOMINAL .018 (.45) SQ NOMINAL 2 PLS The HLMP-0X0X series of rectangular lamps are direct replacements for Agilent's series with the same part numbers. The series is similar to MV5X123 except for the larger lens size. Like the MV5X123, the HLMP-0X0X is stackable. The lamps are tinted and diffused. .100 (2.54) .090 (2.29) NOTES: 1. ALL DIMENSIONS ARE IN INCHES (mm). 2. TOLERANCES ARE 0.010" INCH UNLESS SPECIFIED. 3. AN EPOXY MENISCUS MAY EXTEND ABOUT 0.040" (1mm) DOWN THE LEADS. ABSOLUTE MAXIMUM RATING (TA =25C) Parameter HER YELLOW HEG UNITS Power Dissipation (HLMP-040X=85mA) 135 135 135 mW Peak Forward Current (1sec pluse, 0.3% DC) 90 90 60 mA Continuous DC Forward Current 30 20 30 mA Lead Soldering Time at 260 C 5 5 5 sec Operating Temperature -55 to +100 -55 to +100 -50 to +100 C Storage Temperature -55 to +100 -55 to +100 -50 to +100 C 2001 Fairchild Semiconductor Corporation DS300002 2/27/01 1 OF 4 www.fairchildsemi.com 2.5 X 7.4 mm RECTANGULAR SOLID STATE LAMPS ELECTRICAL / OPTICAL CHARACTERISTICS Parameter (TA =25C) HER YELLOW HEG HLMP- 0300/1 HLMP- 0400/1 HLMP- 0503/4 Luminous Intensity (mcd) Condition IF = 20mA Minimum 1.0 2.5 1.5 3.0 1.5 2.5 Typical 2.5 5.0 2.5 5.0 3.0 5.0 Forward Voltage (V) IF = 20mA Maximum 3.0 3.0 3.0 3.0 3.0 3.0 Typical 2.1 2.1 2.2 2.2 2.3 2.3 Peak Wavelength (nm) 635 635 585 585 565 565 IF = 20mA Spectral Line Half Width (nm) 45 45 35 35 35 IF = 20mA 5 5 IR = 100A Reverse Voltage (V) Viewing Angle () 100 100 www.fairchildsemi.com 2 OF 4 35 5 5 5 5 100 100 100 100 2/27/01 DS300002 2.5 X 7.4 mm RECTANGULAR SOLID STATE LAMPS TYPICAL PERFORMANCE CURVES (TA =25C) 2.5 90 RELATIVE LUMNOUS INTENSITY (NORMALIZED AT 20 mA) IF - FORWARD CURRENT (mA) 80 70 HER 60 50 YELLOW 40 30 20 10 2.0 HER YELLOW GREEN 1.5 1.0 0.5 GREEN 0.0 0 1.0 2.0 3.0 4.0 5.0 0 5 15 20 25 30 Fig. 2 Relative Luminous Intensity vs. DC Forward Current Fig. 1 Forward Current vs. Forward Voltage 50 1.0 GREEN YELLOW HER 40 RELATIVE INTENSITY IF - FORWARD CURRENT (mA) 10 IF - DC FORWARD CURRENT (mA) VF - FORWARD VOLTAGE (V) HER, GREEN 30 YELLOW 20 10 0.5 0 0 0 20 40 60 85 100 500 550 600 TA - AMBIENT TEMPERATURE (C) 650 700 750 WAVELENGTH (nm) Fig. 3 Current Derating Curve Fig. 4 Relative Intensity vs. Peak Wavelength -20 -10 0 10 20 -30 30 0.9 0.8 0.7 -40 40 0.6 0.5 -50 50 0.4 -60 0.3 60 -70 0.2 70 -80 0.1 80 -90 0 90 OFF AXIS ANGLE DEGREES Fig. 5 Spatial Distribution DS300002 2/27/01 3 OF 4 www.fairchildsemi.com 2.5 X 7.4 mm RECTANGULAR SOLID STATE LAMPS DISCLAIMER FAIRCHILD SEMICONDUCTOR RESERVES THE THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS. LIFE SUPPORT POLICY FAIRCHILD'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body,or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in labeling, can be reasonably expected to result in a significant injury of the user. www.fairchildsemi.com 2. A critical component in any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. 4 OF 4 2/27/01 DS300002