Polygon Mirror Scanner Motor
- 9 -
■RELIABILITY TEST DATA
25[℃]·65[%RH] However, the conditions mentioned blow can be applied for testing as far as no
technical problem Temperature : 10~35[℃], Relative humidity : 45~80[%RH]
No Item Measurement Conditions Specifications
(Example)
1 Starting current Measured at 24[V]
Measured at rated voltage and rated load 1.0 [A] or less
2 Rated current Measured at rated voltage and rated load
Measured in about 10[s] after motor starts 0.60 [A] or less
3 Start time
Time after the motor start and before
the lock signal is output in the rated voltage,
rated load. 3.5 [s] or less
Time after the motor start and before
the satisfaction of specifications in the rated
voltage, rated load. 5.0 [s] or less
4Jitter
LF (at 600 facet)
Measured using a standard circuit and jig. 0.020 [%] or less
RF (at 6 facet)
Measured using a standard circuit and jig. 0.010 [%] or less
5 Dynamic balance
Measured using a balancer
Mirror side 1[㎎·㎝]or less
Measured using a balancer
Rotor case side 1[㎎·㎝]or less
Measured using a balancer
Static 2[㎎·㎝]orless
6Pyramid error
of the mirror
at operation
Total
Measured by rotating the motor at the rated
speed of rotation 150[″]p-p or less
Adjacent
Measured by rotating the motor at the rated
speed of rotation 100[″]p-p or less
7NoiseMeasured 1[m] from the side of the motor 60 [dB-A] or less