Current
0.5 A
Voltage
600 V to 1000 V
MECHANICAL DATA
TO-269AA / MBS

Ideal for automated placement
Saves space on printed circuit boards
TYPICAL APPLICATIONS
FEATURES
High surge current capability
Solder dip 260ºC, 10s
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
Meets MSL level 1, per J-STD-020, LF maximum
peak of 260º C
Maximun Ratings and Electrical Characteristics at 25°C
0.5 Amp. Miniature Single Phase Glass Passivated Surface Mount Bridge Rectifier
Used in general purpose ac-to-dc bridge full wave rectification
for power supply, lighting ballaster, Battery charger, home
appliances, office equipement, and terlecommunication
applications.
MB6SA..MB10SA
Maximum Recurrent Peak Reverse Voltage (V)
Maximum RMS Voltage (V)
Maximum DC Blocking Voltage (V)
Maximum Average Forward Output Current
(see Fig. 1) On glass-epoxy P.C.B.
On aluminum substrate
V
RRM
V
RMS
V
DC
I
F(AV)
Typical Junction Capacitance Per Leg
C
j
Typical Thermal Resistance Per Leg
Operating Temperature Range
Storage Temperature Range
T
stg
R
th (j-a)
0.5 A(1)
85 °C/W
(1)
-55 to + 150 °C
30 A
100 µA
I
FSM
V
F
I
R
Maximum Instantaneous Forward Voltage
@ 0.4 A
MB6
600
420
600
1.0 V
13 pF
Peak Forward Surge Current 8.3 ms Single
Half Sine-Wave Superimposed on Rated Load
(JEDEC Method)
Maximum DC Reverse Current @ Ta = 25 °C
at Rated DC Blocking Voltage @ Ta = 125 °C
5 µA
T
j
-55 to + 150 °C
0.8 A(2)
R
th (j-a)
R
th (j-l)
70 °C/W
(2)
20 °C/W
(1)
Notes: 1. On glass epoxy P.C.B. mounted 1.3x1.3mm pads
2. On aluminium substrate P.C.B. whith an area of 20x20mm mounted on 1.3x1.3mm solder pad
MB10
1000
700
1000
MB6SA MB10SA
Marking Code
MB8
800
560
800
MB8SA
www.fagorelectronica.com
Document Name: mbsa Version: Jan-12
Page Number: 1/4

Case: TO-269AA/MBS. Epoxy meets UL 94V-0
flammability rating.

Polarity: As marked on body.

Terminals:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test.
Package Outline Dimensions
:
(mm)
Ordering information
TR 13" diameter tape and reel 3,000 0.22
MB6SA TR
TO-269AA / MBS
0.5 Amp. Miniature Single Phase Glass Passivated Surface Mount Bridge Rectifier
MB6SA..MB10SA
www.fagorelectronica.com
Document Name: mbsa Version: Jan-12
Page Number: 2/4
PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g)
0.25
±0.1
0.9±0.2
1.1±0.2
0.1
±0.2
2.5
±0.2
3 MAX
1.5±0.2 1.5
±0.2
7 MAX
2.5
±0.2
4.7
±0.2
0.6
±0.2
2.5
5.9
1.2
1.2
Marking code
Mounting Pad Layout
MC
Week code
Year code
WWY
4.1
±0.05
Ratings and Characteristics (Ta 25 ºC unless otherwise noted)
0.5 Amp. Miniature Single Phase Glass Passivated Surface Mount Bridge Rectifier
MB6SA..MB10SA
www.fagorelectronica.com
Document Name: mbsa Version: Jan-12
Page Number: 3/4
MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT PER LEG
1
Number of cycles
10 100
35
30
25
15
10
I
FSM
, peak forward surge current (A)
TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER LEG
0.2 0.6 1 1.2 1.4
IF, instantaneous forward current (A)
10
1
0.1
DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
Ambient temperature (ºC)
04020 60 12010080
0.8
0.7
0.6
0.4
0.2
0.1
0
IF(AV), average forward rectified current (A)
30
TYPICAL JUNCTION CAPACITANCE
PER LEG
0.1
200
0
20
10
Cj, junction capacitance (pF)
V
R
, reverse voltage (V)
0.8 1.6
0
V
F
, instantaneous forward voltage (V)
NON INDUCTIVE
50W
PULSE
GENERATOR
(NOTE 2)
SET TIME BASE FOR
5/ 10ns/ cm
1cm
trr
+0.5A
0
-0.25A
-1.0A
1W
NON
INDUCTIVE
DUT
OSCILLOSCOPE
(NOTE 1)
NON INDUCTIVE
10W
(+)
50Vdc
(approx)
(-) (+)
(-)
REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
NOTES: 1. Rise Time = 7ns max. Input Impedance =
1 megohm 22 pf
2. Rise Time = 10 ns max. Sourse Impedance =
50 ohms
TYPICAL REVERSE LEAKAGE
CHARACTERISTICS PER LEG
20 60
Percent of rated peak
reverse voltage (%)
100
1
0.01
40 80 1000
0.1
10
140 160
0.01
T
a
=40°C
Single Half Sine Wave
(JEDEC Method)
Tj
= 125 ºC
T
j
= 25 ºC
I
R
, instantaneous reverse leakage current (mA)
Glass
Epoxy
P. C . B .
0.5
0.3
20
5
0.4
25
15
10
5
100
1
T
j
= 25 °C
f = 1.0 MHz
Vsig = 50mVp-p
Resistive or Inductive Load
Aluminum Substrate
F=60 Hz
F=50 Hz
1 Cycle
Pulse Width=300 µs
1% Duty Cycle
Tj
= 150 °C
T
j
= 25 °C
Disclaimer
0.5 Amp. Miniature Single Phase Glass Passivated Surface Mount Bridge Rectifier
MB6SA..MB10SA
www.fagorelectronica.com
Document Name: mbsa Version: Jan-12
Page Number: 4/4
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.