Product: 1212 Category 5E+ Cable, 4 Pair, U/UTP, CMR Product Description Category 5E+ Premise Horizontal Cable (350MHz), 4 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Riser-CMR, PVC Jacket Technical Specifications Product Overview Suitable Applications: Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/resources/patents. Construction Details Conductor AWG Stranding 24 Solid Material Number of Pairs BC - Bare Copper 4 Insulation Material Color Code PO - Polyolefin White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown Bonded-Pair: No Outer Jacket Material Material Nom. Diameter Ripcord PVC - Polyvinyl Chloride 0.206 in Yes Electrical Characteristics Electricals Max. Conductor DCR Max. DCR Unbalance Max. Capacitance Unbalance Nom. Mutual Capacitance 89 Ohm/km 3% 330 pF/100m 15 pF/ft Delay Frequency [MHz] 100 MHz Max. Delay Max. Delay Skew Nom. Velocity of Propagation (VP) [%] 537.6 ns/100m 25 ns/100m 70% High Freq Frequency [MHz] Max. Insertion Loss (Attenuation) Min. Min. Min. Min. NEXT [dB] PSNEXT [dB] ACR [dB] PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance 1 MHz 2.0 dB/100m 70.3 dB 69.3 dB 68.3 dB 67.3 dB 67.8 dB 65.8 dB 20.0 dB 100 15 Ohm 100 15 Ohm 4 MHz 4.0 dB/100m 61.3 dB 60.3 dB 57.3 dB 56.3 dB 55.8 dB 53.8 dB 23.0 dB 100 15 Ohm 100 15 Ohm 8 MHz 5.7 dB/100m 56.8 dB 55.8 dB 51.1 dB 50.1 dB 49.7 dB 47.7 dB 24.5 dB 100 15 Ohm 100 15 Ohm 10 MHz 6.4 dB/100m 55.3 dB 54.3 dB 48.9 dB 47.9 dB 47.8 dB 45.8 dB 25.0 dB 100 15 Ohm 100 15 Ohm 16 MHz 8.1 dB/100m 52.2 dB 51.2 dB 44.1 dB 43.1 dB 43.7 dB 41.7 dB 25.0 dB 100 15 Ohm 100 15 Ohm 20 MHz 9.1 dB/100m 50.8 dB 49.8 dB 41.7 dB 40.7 dB 41.8 dB 39.8 dB 25.0 dB 100 15 Ohm 100 15 Ohm 25 MHz 10.2 dB/100m 49.3 dB 48.3 dB 39.1 dB 38.1 dB 39.8 dB 37.8 dB 24.3 dB 100 15 Ohm 100 15 Ohm 31.25 MHz 11.4 dB/100m 47.9 dB 46.9 dB 36.4 dB 35.4 dB 37.9 dB 35.9 dB 23.6 dB 100 15 Ohm 100 15 Ohm 62.5 MHz 16.4 dB/100m 43.4 dB 42.4 dB 27.0 dB 26.0 dB 31.9 dB 29.9 dB 21.5 dB 100 15 Ohm 100 15 Ohm 100 MHz 21.0 dB/100m 40.3 dB 39.3 dB 19.3 dB 18.3 dB 27.8 dB 25.8 dB 20.1 dB 100 15 Ohm 100 15 Ohm 155 MHz 26.6 dB/100m 37.4 dB 36.4 dB 10.9 dB 9.9 dB 24.0 dB 22.0 dB 18.8 dB 100 22 Ohm 100 15 Ohm 200 MHz 30.5 dB/100m 35.8 dB 34.8 dB 5.3 dB 4.3 dB 21.8 dB 19.8 dB 18.0 dB 100 22 Ohm 100 15 Ohm 250 MHz 34.4 dB/100m 34.3 dB 33.3 dB -0.1 dB -1.1 dB 19.8 dB 17.8 dB 17.3 dB 100 32 Ohm 100 15 Ohm 300 MHz 38.0 dB/100m 33.1 dB 32.1 dB 18.3 dB 16.3 dB 14.4 dB 100 32 Ohm 100 15 Ohm 350 MHz 41.4 dB/100m 32.1 dB 31.1 dB 16.9 dB 14.9 dB 13.8 dB 100 32 Ohm 100 15 Ohm 400 MHz 44.6 dB/100m 31.3 dB 30.3 dB 15.8 dB 13.8 dB 13.3 dB 100 32 Ohm 100 15 Ohm 450 MHz 47.7 dB/100m 30.5 dB 29.5 dB 14.7 dB 12.7 dB 12.8 dB 100 32 Ohm 100 15 Ohm Voltage UL Voltage Rating 300 V (CMR) Mechanical Characteristics Temperature UL Rating. 75C Operating Installation Storage -20C To +75C 0C To +50C -20C To +75C Bend Radius Stationary Min. Installation Min. 1.0 in 2.25 in Max. Pull Tension: 25 lbs Bulk Cable Weight: 20 lbs/1000ft Standards and Compliance Environmental Suitability: Riser, Indoor Sustainability: Product LensTM, Environmental Product Declaration (EPD) Available Flammability / Fire Resistance: UL 1666 Riser, FT4, FT4, IEC 60332-1-2 NEC / UL Compliance: Article 800, CMR CEC / C(UL) Compliance: CMR ICEA Compliance: S-90-661-2012 IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3 NEMA Compliance: NEMA WC-63.1 Data Category: Category 5e TIA/EIA Compliance: ANSI/TIA-568.2-D Category 5e CPR Euroclass: Eca European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 APAC Compliance: China RoHS II (GB/T 26572-2011) Part Number Plenum Number: 1213 Variants Item # Color UPC 1212 010U1000 Black 612825061410 1212 0061000 Blue 612825061519 1212 0062500 Blue 612825061434 1212 006U1000 Blue 612825061427 1212 008U1000 Gray 612825061465 1212 005U1000 Green 612825061441 1212 003U1000 Orange 612825061458 1212 0091000 White 612825061489 1212 009U1000 White 612825061472 1212 0041000 Yellow 612825062189 1212 004U1000 Yellow 612825061496 Product Notes Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 350 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. History Update and Revision: Revision Number: 0.321 Revision Date: 09-30-2020 (c) 2021 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.