CD series
CMOS IC Time Delay Relay
• 1% Repeatability
• Operates from -40°C to +55°C
•Delay on operate or delay on release timing modes
•Fixed, knob or resistor adjustable types
– Calibrated dial on knob adjustable types
•10A output relay with SPDT or DPDT contacts
•Various models time from 0.1 to 180 sec.
File E22575
File LR15734
Contact Data @ 25°C
Arrangements: 2 Form C (DPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @
120VAC.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
Input Data @ 25°C
Voltage: 24 & 120VAC and 12 through 110VDC.
Power Requirement: AC Types: Typically less than 3 VA.
DC Types: Typically less than 3 W.
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Initial Dielectric Strength
Between Open Contacts: 500V rms, 60 Hz.
Between All Other Conductors: 500V rms, 60 Hz.
Environmental Data
Temperature Range: Storage: -55°C to +85°C.
Operating: -40°C to +55°C.
Mechanical Data
Termination: 8- or 11-pin octal style plug.
Enclosure: Yellow plastic case. Knob adjustable types have dial scale
calibrated in seconds ±5%.
Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on)
screw terminal sockets. 11-pin types fit either 27E123 or
27E892 (snap-on) screw terminal sockets.
Weight: 8 oz. (227g) approximately.
Timing Modes
Delay on operate – Delay period begins when input voltage is applied. At
the end of the delay period, the relay will operate and will not release until
input voltage is removed. Reset occurs when input voltage is reapplied.
Delay on release – Input voltage must be applied continuously to operate
the internal relay. When control Input is applied, the relay energizes.
When control input is removed, timing begins. When timing is complete,
the relay will de-energize. Time may be reset to zero during timing by
reapplying control input.
Timing Specifications
Timing Ranges: From 0.1 to 180 sec.
Timing Adjustment: Fixed, external resistor and knob adjustable.
Tolerance (for AC units add ±1/2 cycle 60 Hz.):
Knob Adj. Types: ±5% of max. specified at high end of timing range; min.
specified, or less, at low end; ±10% full scale.
Fixed Types: ±5%.
Res. Adj. Types: ±5% at high end of timing range; min. specified, or less,
at low end.
Delta Time (for AC units add ±1 cycle 60 Hz.): ±5%.
Repeatability (for AC units add ±1 cycle 60 Hz.): ±1%.
Release Time: 45 ms, typ.; 60 ms, max.
Recycle Time: 45 ms, typ.; 60 ms, max.
TIME
INPUT
VOLTAGE ON
OFF
N.O. RELAY
CONTACTS ON
OFF
➛
➛
N.O. RELAY
CONTACTS ON
OFF
CONTROL
INPUT ON
OFF
TIME
➛
➛
Input Voltages & Limits @ 25°C
Voltage Nominal Minimum Maximum
Type Voltage Voltage Voltage
AC 24 20 28
120 105 130
12 11 13
DC 24 20 32
48 41 55
110 95 125
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.