LD-P (ALDP)
2ds_61B10_en_ldp: 260313D
RATING
1. Coil data
2. Specifications
Notes:
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2 Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3 The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. allowable voltage
(at 20C 68F)
5V DC
75%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
40.0mA 125
200mW 130%V of
nominal voltage
6V DC 33.3mA 180
9V DC 22.2mA 405
12V DC 16.7mA 720
18V DC 11.1mA 1,620
24V DC 8.3mA 2,880
Characteristics Item Specifications
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Contact material AgNi type
Rating
Nominal switching capacity (resistive load) 5A 277V AC
Max. switching power (resistive load) 1,385VA
Max. switching voltage 277V AC
Max. switching current 5A
Min. switching capacity (reference value)*1100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*2
(Between contact and coil) 10,000 V (initial)
Temperature rise Max. 30C 86F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 5A, at 85C 185F)
Operate time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance Functional Min. 300 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life Mechanical (at 180 cpm) Min. 5106
Electrical (at 20 cpm) Min. 2105 (5A 125V AC at rated load), Min. 105 (5A 250V AC at rated load)
Conditions
Conditions for operation, transport and storage*3Ambient temperature: –40C to +85C –40F to +185F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed
(at nominal switching capacity) 20 times/min.
Unit weight Approx. 4 g .14 oz