www.mccsemi.com
MBR20200CT
20 Amp High Voltage
Features
High Junction Temperature Capability
Good Trade Off Between Leakage Cur-
rent And Forward Volage Drop
Low Leakage Current
MCC
Catalog
Number
Maximum
Re current
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MBR 20 2 0 0 CT 2 0 0 V 140V 200 V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 20 A TC = 125°C
Peak Forward Surge
Current IFSM 150A 8.3ms, half
Maximum
Instantaneous
Forward Voltage
MBR 20200CT
VF
.95 V
MCC
*Pulse Test: Pulse Width38 0µsec, Duty Cycle 2%
I
FM = 10A
TJ = 25°C

INCHES MM
     
A .600 .620 15.25 15.75
B .393 .409 10.00 10.40
N 0.102ty p. 2.6typ.

PIN 1
PIN 3 PIN 2
CASE
A
B
C
K
J
I
H
G
F
E
D
N
M
L
H
200Volts
TO-220AB
PIN
13
Maximum Ratings
Operating Junction Temperature : 150°C
Storage Temperature: - 5 0 °C to +150°C
omponents
21201 Itasca Street Chatsworth

 !"#
$% !"#
C .104 .116 2.65 2.95
D .244 .259 6.20 6.60
E .356 .361 9.05 9.15
F .137 .154 3.50 3.93
G .511 .551 13.00 14.00
H .094 .106 2.40 2.70
I .024 .034 0.61 0.88
J .019 .027 0.49 0.70
K .147 .151 3.75 3.85
L .173 .181 4.40 4.60
M .048 .051 1.23 1.32
Barrier Rectifier
Power Schottky
Maximum
Reverse Current At
Rated DC Blocking
Voltage
IR
50uA T
c = 25°C
15mA T
c = 125°C
VF
.80V I
FM = 10A
T
J = 125°C
sine wave
www.mccsemi .com
MBR20200CT MCC
Figure 1. Typical Forward Voltage (Per Leg)
100
70
50
20
10
7
5
2
10.2 0.4 0.6 0.8 1
TJ = 125°C
TJ = 100°C
TJ = 25°C
vF, INSTANTANEOUS VOLTAGE (VOLTS)
TJ = 150°C
I , INSTANEOUS FORWARD CURRENT (AMP)
F
I , REVERSE CURRENT ( A)
Rµ
VR, REVERSE CURRENT (VOLTS)
10,000
1,000
100
10
1
0.1
0.01 20 40 60 80 100 120 140 160 180 200
TJ = 125°C
TJ = 100°C
TJ = 150°C
TJ = 25°C
Figure 2. Typical Reverse Current (Per Leg)
0
40
36
32
28
24
20
16
12
8
4
0
0 5 10 15 20 25 30 35
TJ = 125°C
10
dc
SQUARE
WAVE
IPK
IAV
= 20
IF(AV), AVERAGE FORWARD CURRENT (AMPS)
Figure 3. Forward Power Dissipation
P , AVERAGE POWER DISSIPATION (WATTS)
F(AV)
25
20
15
10
5
090 100 110 120 130 140 150 160
I , AVERAGE FORWARD CURRENT (AMPS)
F(AV)
TC, CASE TEMPERATURE (°C)
Figure 4. Current Derating, Case
SQUARE
WAVE
dc
RATED VOLTAGE
RθJC = 2°C/W
I , AVERAGE FORWARD CURRENT (AMPS)
F(AV)
RθJA = 16°C/W
RATED VOLTAGE
20
16
12
8
4
0
TA, AMBIENT TEMPERATURE (°C)
Figure 5. Current Derating, Ambient
dc
SQUARE
WAVE
0 25 50 75 100 125 150 175
500
400
300
200
100
0
C, CAPACITANCE (pF)
TJ = 25°C
VR, REVERSE VOLTAGE (VOLTS)
1 2 5 10 20 50 70 100
Figure 6. Typical Capacitance (Per Leg)