Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
Multi-Deck Rotary Switches
DIMENSIONS In inches (and millimeters)
Note: Common location for a single pole per
deck switch. For common location on
multi-pole switches, see circuit diagrams.
Front view shows terminal location of
36° angle of throw. Transpose rear
view for terminal location of 30° angle
of throw. See Circuit Diagrams for 60°
and 90° angles of throw.
PC Mount Style
SERIES 08
SERIES 09
.5" Diameter, 1/4 Amp, PC Mount
*Termination
A standard switch uses the entire 360° of each deck as required by the circuitry.
Thus one-sided termination is standard for Series 08, 36°, 1 pole switches with 1 to
5 positions per pole; it is also standard for Series 09, 30°, 1 pole switches with 1 to
6 positions per pole. Two-sided termination is standard for 1 pole switches with more
positions per pole and for switches of 2 or more poles per deck.
Special switches with one-sided termination can be made for circuitry which would
require two-sided termination in standard switches. Contact Grayhill for a special
part number. See also Special Options, page J-10.
Grayhill part number and date code marked on detent cover label. Customer
part number marked on request.
Rear Views
Series 09
30° Angle of Throw
Series 08
36° Angle of Throw
NON-TURN TAB .062 ± .005
(1,58 ± 0,13) WIDE BY
.020 ± .003 (0,51 ± 0,08) THICK
SEE NOTE
.260 ± .015
(6,60 ± 0,38) C
L OF NON-
TURN
TAB
.094 ± .010
(2,38 ± 0,25)
DIM. A + .046 – .020
(+ 0,05 – 0,51) DIM. B REF.
STUD
PROJECTION
#0 THREAD
.375 ± .020
(9,53 ± 0,51)
.312 ± .020
(7,92 ± 0,51)
.125 + .001 – .002
(3,18 + 0,03 – 0,05)
DIA.
1/4-32 UNEF-2A THREAD
INTEGRAL ASSEMBLY NUT,
DO NOT REMOVE
COMMON LUG
.562 (14,27) SER. 8
.625 (15,88) SER. 9
± .015 (0,38)
C
L
.250 ± .020
(6,35 ± 0,51)
C
L C
L
.134 ± .010
(3,40 ± 0,25)
.135 ± .015 (3,43 ± 0,38)
.134
± .010
(3,40
± 0,25)
.588 ± .020
(14,73 ± 0,51)
1
2
3
4
5
6
7
8
9
10
GRAYHILL
.562 ± .020
(14,27 ± 0,51)
DIA.
.187 ± .015
(4,75 ± 0,38)
TYP.
.140 ± .015
(3,56 ± 0,38)
TYP.
11
12
1.200 ± .020
(30,48 ± 0,51)
TYP.
.070 ± .010
(1,78 ± 0,25)
TYP.
1
2
3
4
5
6
7
9
9
10
GRAYHILL
.500 ± .020
(12,7 ± 0,51)
DIA.
1.125 ± .020
(28,58 ± 0,51)
TYP.
.187 ± .015
(4,75 ± 0,38)
TYP.
.140 ± .015
(3,56 ± 0,38)
TYP.
TERMINAL DIMENSIONS AT
THIS POINT ARE .032 + .000 – .010
(0,81 + 0,00 – 0,25) WIDE
BY .015 + .000 – .003
(0,38 + 0,00 – 0,08) THICK
FEATURES
Gold-plated Contact System
30°, 36°, 60° or 90° Angle of
Throw Options
Compatible with Logic Level
Voltages and Currents
Rotary
18
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
Multi-Deck Rotary Switches
SHAFT AND PANEL SEAL
A shaft and panel seal is available to provide watertight mounting of the Series 08
and 09. Standard and Military Style rotary switches. Sealing is accomplished by
O-ring shaft seal and panel seal washer. When the panel seal is compressed,
dimensions are approximately the same as an unsealed switch. Sealed switches are
provided with a double flat bushing. Non-turn feature can be accomplished by proper
fit of this bushing into panel hole and/or by allowing non-turn tab to extend into (but
not through) panel. Military Style rotary sealed switches do not have a non-turn tab.
CIRCUIT DIAGRAMS: PC Mount
Switch is Viewed From Shaft End and Shown in Position No. 1
Note: All common terminals are located above base terminals as shown.
PC BOARD MOUNTING PATTERN
Series 09
30° Angle
of Throw
ONE POLE TWO POLE ONE POLE TWO POLE
Series 08
36° Angle
of Throw
ONE POLE TWO POLE ONE POLE TWO POLE
Number of Poles Common Terminal
Per Deck Hole Location
1 Pole Per Deck A
2 Poles Per Deck A
30°, 60° and 90° Angle of Throw
36° Angle of Throw
Diagrams shown for a two deck switch. Bushing mounting is
recommended for all PC mount rotary switches.
Base Terminals
Angle of Throw Hole Location
30° All
60° E and F
90° D and F
Series 09
60° Angle
of Throw
Series 09
90° Angle
of Throw
C1
1
2
3
4
5
6
7
8
9
10
11
12
C
LOF
NON-TURN
TAB
C1
1
2
3
4
5
6
7
8
9
10
11
12
C2 C
L
7
65
4
3
2
1
8
9
10
C1
C
LOF
NON-TURN
TAB
7
65
4
3
2
1
8
9
10
C1 C
L
C2
C1
1
2
3
4
5
6
C
LOF
NON-TURN
TAB
C1
1
2
3
4
5
6
C
L
C2
C1
1
2
3
4
C
LOF
NON-TURN
TAB
C1
1
2
3
4C
L
C2
.134 (3,40) TYP.
.134 (3,40) TYP.
.210
(5,33)
TYP.
.280
(7,11)
TYP.
SHAFT END
OF SWITCH
E
C
D
A
C
B
F
E
D
.070
(1,78)
.140
(3,56)
TYP.
COMMON TERMINAL ROW
HOLE LOCATION (SEE CHART)
BASE TERMINAL
ROW HOLE LOCATION
(SEE CHART)
.134 (3,40) TYP.
.134 (3,40) TYP.
.140
(3,56)
TYP.
SHAFT END
OF SWITCH
Rotary
19
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
Multi-Deck Rotary Switches
MILITARY QUALIFIED
Materials and Finishes
Military Qualified
Deck Separators, End Plate and Switch Bases:
Diallyl per (MIL-M-14) ASTM-D-5948
Rotor Mounting Plate: Thermoplastic
Mounting Bushing: Brass, tin/zinc-plated.
Shaft, Cover, Stop Plate, Retaining Ring,
Through Bolts, Shaft Extension, Stop Arm,
Thrust Washers, Cover Plate and Rear Support
Plate, Lockwashers and Nuts: Stainless steel
Detent Balls: Steel, nickel-plated
Detent Springs: Tinned music wire
Terminals, Stator (Base) Contacts and
Common Plate: Brass, gold plate .00001"
minimum over silver plate .0003" minimum
Rotor Contact: Silver alloy, gold-plated .00001"
minimum
Mounting Hardware: Two mounting nuts .062"
(1,57) thick by .312" (7,92) across flats and one
internal tooth lockwasher are supplied with this
switch.
Mounting Nuts, Washers: Brass, tin/zinc-
plated and or stainless steel.
ADDITIONAL CHARACTERISTICS
Standard Style and Military Qualified
Contacts: Shorting or Non-shorting contacts
available in 30°, 36° and 45° angle of throw rotary
switches. Non-shorting contacts available in 60°
and 90° angle of throw switches. All are wiping
contacts with over 100 grams of contact force.
Stop Strength: 12 lb-inches minimum
Rotational Torque: 8-64 oz-in depending upon
the number of poles per deck and the number of
decks
Extended Studs: Switches of six decks or more
have longer studs with extra stud nuts for
recommended double end mounting.
Contact Resistance: 50 milliohms maximum after
life
Insulation Resistance: 1,000 megaohms
minimum between terminals and shaft
Dielectric Strength: 500 Vac (atmospheric
pressure) and 350 Vac (reduced pressure)
between mutually insulated parts.
The Series 08M and 09M also meet the
requirements of MIL-DTL-3786 SR13 for moisture
resistance, stop strength, rotational torque,
vibration (10 to 2,000 cps), medium and high
shock, salt spray, explosion, thermal shock (-
65°C to 85°C) and terminal pull. When tested at
sea level, 25°C and 68% relative humidity with
failure criteria of 50 milliohms maximum contact
resistance and 500 Vac breakdown voltage, these
switches will make and break 250 mA at 28 Vdc
inductive (250 millihenries): 1/2 amp: at 28 Vdc
resistive: 1/2 amp; at 115 Vac: 60 Hz resistive for
10,000 cycles of operation.
Materials and Finishes
Standard Style
Switch Bases: Melamine per (MIL-M-14) ASTM-
D-5948
Cover, Deck Separators and End Plate: Phenolic
per (MIL-M-14) ASTM-D-5948
Rotor Mounting Plate: Thermoplastic
Mounting Bushing: Brass, tin/zinc-plated.
Shaft, Retaining Rings, Through Bolts, Shaft
Extension, Stop Washers, Stop Arm, Thrust
Washers, Nuts, Cover Plate and Rear Support
Plate: Stainless steel
Detent Balls: Steel, nickel-plated
Detent Springs: Tinned Music wire
Terminals, Stator (Base) Contacts and
Common Plate: Brass, gold plate .00001"
minimum over silver plate .0003" minimum
Rotor Contact: Silver alloy, gold-plated .00001"
minimum
Mounting Hardware: Two mounting nuts .062"
(1,57) thick by .312" (7,92) across flats and one
internal lockwasher are supplied with switch.
Lockwasher: Stainless steel
Mounting Nuts, Washers: Brass, tin/zinc-
plated and or stainless steel.
Terminal Detail
Front view shows terminal location of
Series 09, 30° angle of throw.
Transpose rear view for terminal location
of other angles of throw.
Note: Common location for a single pole per
deck switch. For common location on
multi-pole switches, see circuit diagrams.
Series 09
30° Angle of Throw
Series 08
36° Angle of Throw
.034 ± .003
(0,86 ± 0,08) .068 ± .005
(1,73 ± 0,13)
.094 ± .010
(2,38 ± 0,25)
.260 ± .015
(6,60 ± 0,38) C
L OF NON-TURN
TAB
SEE NOTE
8
9
10
1
2
3
4
5
6
7
GRAYHILL
11
12
.781 ± .020
(19,83 ± 0,51)
OVER TERMINALS
.562 ± .020
(14,27 ± 0,51)
DIA.
15°
30°
8
9
10
1
2
3
4
5
6
7
GRAYHILL
.500 ± .020
(12,7 ± 0,51)
DIA.
.718 ± .020
(18,24 ± 0,51)
OVER
TERMINALS
36°
Series 08 and 09 military switches are qualified
to MIL-DTL-3786/13. They include 30°, 36°, 45°
and 60° angles of throw with solder lug terminals
in sealed and unsealed styles. See front and
rear views at right. Standard variations which do
not affect switch performance can also be marked
as qualified product–contact Grayhill.
The military style is dimensionally the same as
the standard except for the solder lug. Convert
standard style switch drawings to military style
drawings by including this terminal detail and
changing the over-terminal dimensions shown
here. Grayhill can provide complete specification
drawings. Qualified switches can be ordered by
the Grayhill number or the "M" number; they will
be marked per MIL-DTL-3786/13.
SPECIFICATIONS
Electrical Ratings
Standard Style
Rated: To make and break the following loads:
1/4 amp, 115 Vac resistive; 1/4 amp, 6-28 Vdc
resistive; 20 mA, 115 Vdc resistive; 50 mA, 115
Vac inductive; 20 mA, 28 Vdc inductive; to carry
4 amps continuous.
Contact Resistance: After 25,000 cycles of
operation, 50 milliohms maximum
Insulation Resistance: 1,000 megohms
minimum between terminals and shaft
Voltage Breakdown: 1,000 Vac initially
(500 Vac or better after most environmental tests)
Life Expectancy: 50,000 mechanical cycles of
operation.
Note:
Actual life is determined by a
number of factors, including electrical loading,
rate of rotation and environment, as well as
maximum contact resistance, minimum insulation
resistance and minimum voltage breakdown
required at the end of life.
Electrical Ratings
Military Qualified
Qualified to the following MIL-DTL-3786/13
Circuit Values: (Also see Standard Style
description.) The Series 08M and 09M have been
tested to meet the requirements of MIL-S-3786,
Style SR13, the majority of which are listed. At
85°C, approximately 68% relative humidity and
sea level pressure, the switches have been tested
to make and break the following loads, as stated
in MIL-DTL-3786/SR13: 125 milliamperes at 28
Vdc resistive: 75 milliamperes at 115 Vac resistive.
The switches have also been tested at reduced
barometric pressure (70,000 feet), 25°C at
approximately 68% relative humidity to make and
break the following loads as stated in MIL-DTL-
3786/SR13. 50 milliamperes 28 Vdc resistive; 20
milliamperes 115 Vac resistive. When tested to
the above loads at the stated conditions, the
Series 08M and 09M switches meet the following
life-limiting criteria after 25,000 cycles of operation
in accordance with MIL-DTL-3786.
Rotary
20
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
Multi-Deck Rotary Switches
Angle Number of Decks Poles Number of
Series Style and Designation of Throw Stops Terminals Shorting Non-Shorting Per Deck Positions/Pole
A = Standard
S = Standard, Shaft/Panel Seal
M = Military Style
MS = Style M, Shaft/Panel Seal
P = Standard, PC Mount
SP = Style P, Shaft/Panel Seal
MP = Military Style, PC Mount
MSP = Style MP, Shaft/Panel Seal
A = Standard
S = Standard, Shaft/Panel Seal
M = Military Style
MS = Style M, Shaft/Panel Seal
P = Standard, PC Mount
SP = Style P, Shaft/Panel Seal
MP = Military Style, PC Mount
MSP = Style MP, Shaft/Panel Seal
A = Standard,
S = Standard, Shaft/Panel Seal
M = Military Style
MS = Style M, Shaft/Panel Seal
A = Standard,
S = Standard, Shaft/Panel Seal
M = Military Style
MS = Style M, Shaft/Panel Seal
P = Standard, PC Mount
SP = Style P, Shaft/Panel Seal
MP = Military Style, PC Mount
MSP = Style MP, Shaft/Panel Seal
A = Standard
S = Standard, Shaft/Panel Seal
P = Standard, PC Mount
SP = Style, Shaft/Panel Seal
Solder
Printed
Circuit
Solder
Printed
Circuit
Solder
Printed
Circuit
Solder
Printed
Circuit
Fixed
Fixed
36°
30°
45°
60°
90°
08
09
CHOICES AND LIMITATIONS
Series: determined by the angle of throw
Style*: Letter(s) from the Choices and Limitations chart
Angle of Throw: Must agree with Series Number
09A30–03–1–12N–F
Stop Arrangement: Add letter C or F to a one pole per deck switch with the maximum number of positions
for a stop between position 1 and the last position.
Type of Contacts: N = Non-shorting; S = Shorting
Positions Per Pole: Requires 02 positions as a minimum to the maximum allowable dependent on the angle
of throw and poles per deck
Poles Per Deck: As limited by angle of throw and switch style
Number of Decks: As limited by the angle of throw, the poles per deck, switch style and types of contacts
* All rotary switches that are required to have military designated markings and testing adhering to MIL-3786 are to be ordered by specifying
the military part number identified on the appropriate slash sheet.
01 thru 12 01 thru 12 1 02 thru 10
01 thru 09 01 thru 09 2 02 thru 05
01 thru 12 01 thru 12 1 02 thru 10
01 thru 09 01 thru 09 2 02 thru 05
01 thru 12 01 thru 12 1 02 thru 12
01 thru 09 01 thru 09 2 02 thru 06
01 thu 06 01 thru 06 3 02 thru 04
01 thru 04 01 thru 04 4 02 or 03
01 thru 03 01 thru 03 5 02
01 thru 03 01 thru 03 6 02
01 thru 12 01 thru 12 1 02 thru 12
01 thru 09 01 thru 09 2 02 thru 06
01 thru 12 01 thru 12 1 02 thru 08
01 thru 06 01 thru 06 2 02 thru 04
01 thru 04 01 thru 04 3 02
01 thru 03 01 thru 03 4 02
01 thru 06 1 02 thru 006
01 thru 03 2 02 or 03
01 or 02 3 02
Not 01 thru 06 1 02 thru 06
Available 01 thru 03 2 02 or 03
Not 01 thru 06 1 02 thru 04
Available 01 thru 03 2 02
Not 01 thru 06 1 02 thru 04
Available 01 thru 03 2 02
ORDERING INFORMATION
Not
Available
Available from your local Grayhill Distributor For prices and discounts, contact a Local Sales Office, an authorized local Distributor or Grayhill.
Rotary