Presentation Zelio Time - timing relays DIN rail mounted relays A timing relay is a component which is designed to time events in industrial automation systems by closing or opening contacts before, during or after a set timing period. Presentation There are two main 'families' of timing relays: b "DIN rail mounted" relays (RE7, RE8, RE9, RE17, REXL...) designed for mounting on DIN rails in an enclosure, b "Panel mounted" relays type RE48A designed for mounting on the front of a panel to give users easy access to the settings. RE17 RE7, RE8, RE9 Panel mounted relays REXL These relays have one, two or four outputs. Sometimes the second output can be either timed or instantaneous. If the power is switched off during the timing period, the relay reverts to its initial position. Application examples: b opening of automatic doors, b alarm, b lighting in toilets, b car park barriers ... RE48A Definitions The following definitions will assist in understanding the operation of these relays: b Relay output: This is the most common type of output. When the relay is energized, the moving armature is attracted by the coil and so actuates the contacts, which change state. When the relay is de-energized, both the armature and the contacts revert to their initial position. This type of output allows complete isolation between the supply and the output. There are three types of output: C/O: changeover contact, i.e. when the relay is de-energized, the circuit between the common point C and N/C is closed and when the relay is operating (coil energized), it closes the circuit between the common point C and N/O. NC C NO N/C: a contact that is closed without being actuated is called a Normally Closed (N/C) contact. NC N/O: a contact that closes when actuated is called a Normally Open (N/O) contact. NO b Solid state output: These outputs are entirely electronic and involve no moving parts; service life is therefore increased. b Breaking capacity: The current value that a contact is capable of breaking in specified conditions. b Mechanical durability: The number of mechanical operating cycles of the contact or contacts. b Minimum switching capacity (or minimum breaking capacity): corresponds to the minimum required current which can flow through the contacts of a relay. b G (Gate) Input: Gate input allows timing in progress to be interrupted without resetting it. 2 28400-EN version: 2.0 Presentation (continued) Zelio Time - timing relays Definitions (continued) Functions Timing functions are identified by letters. Main timing functions Complementary Definitions functions (1) A (2) Power on delay relay Ac On-delay and off-delay relay with control signal Ad Pulse delayed relay with control signal Ah Pulse delayed relay (single cycle) with control signal Ak Asymmetrical On-delay and Off-delay with external control At Power on delay relay (summation) with control signal Aw Off-delay on energization or on opening of control contact B (2) Interval relay with control signal Bw Double interval relay with control signal C (2) Off-delay relay with control signal D (2) Symmetrical flasher relay (starting pulse off) Di (2) H (2) Symmetrical flasher relay (starting pulse on) Interval relay He Pulse-on de-energization Ht Interval relay (summation) with control signal K Delay on de-energization (without auxiliary supply) L (2) Asymmetrical flasher relay (starting pulse off) Li (2) Asymmetrical flasher relay (starting pulse on) Lt Asymmetrical flashing with partial stop of timing N Retriggerable interval relay with control signal on O Retriggerable interval delayed relay with control signal on P Pulse delayed relay with fixed pulse length Pt Pulse delayed relay (summation and fixed pulse length) with control signal off Qc Star-delta timing Qe Star-delta timing Qg Star-delta timing Qt Star-delta timing T Bistable relay with control signal on Tt W Retriggerable bistable relay with control signal on Interval relay with control signal off (1) Complementary functions enhance the main timing functions. Example: Ac: timing after closing and opening of control contact. (2) The most commonly used timing functions. 28400-EN version: 2.0 3 Selection Zelio Time - timing relays Selection table Selection criteria b Functions (On-delay or Off-delay, counter, flashing...) b Supply voltage (example: a/c 12 V...240 V). b Timing range for a timing relay (example: 0.05 s...100 h) b Type of output (contact or solid state) and required Number of contacts. b Breaking capacity or Rated current of contacts, expressed in Amperes. This is the maximum current which may flow through the contacts. Functions Timing range Supply voltage Type of output Rated current Relay A 0.1 s...100 h c 12 V 2 C/O contacts 5A REXL2TMJD 4 C/O contacts 3A REXL4TMJD 2 C/O contacts 5A REXL2TMBD 4 C/O contacts 3A REXL4TMBD 2 C/O contacts 5A REXL2TMB7 4 C/O contacts 3A REXL4TMB7 5A REXL2TMF7 0.1 s...100 h c 24 V 0.1 s...100 h a 24 V 0.1 s...100 h a 120 V 2 C/O contacts 4 C/O contacts 3A REXL4TMF7 0.1 s...100 h a 230 V 2 C/O contacts 5A REXL2TMP7 4 C/O contacts 3A REXL4TMP7 0.1 s...10 s a/c 24...240 V 1 solid state output 0.7 A RE9TA11MW 0.3 s...30 s 0.7 A RE9TA31MW 3 s...300 s 0.7 A RE9TA21MW 40 s...60 min 0.7 A RE9TA51MW 1 s...100 h 0.7 A RE17LAMW 0.02 s...300 h 0.05 s...300 h a/c 24 V, a 110...240 V 2 timed C/O contacts 5 A RE48ATM12MW 1 C/O contact RE7TL11BU 8A 0.1 s...3 s 8A RE8TA61BUTQ 0.1s...10 s 8A RE8TA11BUTQ 0.3 s...30 s 8A RE8TA31BUTQ 3 s...300 s 8A RE8TA21BUTQ 20...30 min 8A RE8TA41BUTQ 0.05 s...300 h a/c 24 V, a 110...240 V, a/c 42...48 V 2 C/O contacts 8A RE7TP13BU 1 s...100 h a 24...240 V 1 solid state output 0.7 A RE17LMBM 1 s...100 h a/c 12 V 1 C/O contact 8A RE17RMJU 1 s...100 h a/c 12...240 V 1 C/O contact 8A RE17RMMW 8A RE17RMMWS 1 s...100 h c 24 V, a 24...240 V 1 C/O contact 8A RE17RMMU A, At 1 s...100 h c 24 V, a 24...240 V 1 C/O contact 8A RE17RAMU A, At, Aw 0.05 s...300 h a 110...240 V, a/c 24 V, a/c 42...48 V 1 C/O contact 8A RE7TM11BU A, At, B, C, D, Di, H, Ht 1 s...10 h c 24 V, a 24...240 V 1 C/O contact 8A RE17RMEMU A, B, C, Di 0.02 s...300 h a/c 24...240 V 2 C/O contacts 5A RE48AML12MW A, C, D, Di, H, Qg, Qt, W 0.05 s...300 h a 110...240 V, a/c 24 V, a/c 42...48 V 2 C/O contacts 8A RE7MY13BU 0.05 s...300 h a/c 24...240 V 2 C/O contacts 8A RE7MY13MW A, C, D, Di, H, W 0.05 s...300 h a 110...240 V, a/c 24 V, a/c 42...48 V 1 C/O contact 8A RE7ML11BU A, D, Di, H 0.1 s...10 s and 3 s...300 s a/c 24...240 V a 24...240 V 1 solid state output 0.7 A RE9MS21MW A1, A2, H1, H2 0.02 s...300 h a/c 24...240 V 2 C/O contacts 5A RE48AMH13MW Ac 0.05 s...300 h a 110...240 V, a/c 24 V, a/c 42...48 V 1 C/O contact 8A RE7MA11BU 2 C/O contacts 8A RE7MA13BU A, Ac, At, B, Bw, C, D, Di, H, Ht Ad, Ah, N, O, P, Pt, T, Tt, W 1 s...100 h c 24 V, a 24...240 V 1 C/O contact 8A RE17RMXMU Ak 0.05 s...300 h a 110...240 V, a/c 24 V, a/c 42...48 V 1 C/O contact 8A RE7MV11BU 4 28400-EN version: 2.0 Selection (continued) Zelio Time - timing relays Selection table (continued) Functions Timing range Supply voltage Type of output Rated current Relay RE17RBMU B 1 s...100 h c 24 V, a 24...240 V 1 C/O contact 8A C 0.1 s...10 s a/c 24 V 1 C/O contact 8A RE8RA11BTQ 8A RE8RA31BTQ 0.3 s...30 s 3 s...300 s 8A RE8RA21BTQ 1 s...100 h c 24 V, a 24...240 V 1 C/O contact 8A RE17RCMU 0.1 s...10 s a 110...240 V 1 C/O contact 8A RE8RA11FUTQ 0.3 s...30 s 8A RE8RA31FUTQ 3 s...300 s 8A RE8RA21FUTQ 8A RE8RA41FUTQ 20 s...30 min 0.05 s...300 h 0.1 s...10 s D a/c 24 V, a 110...240 V, 1 C/O contact a/c 42...48 V a 24...240 V RE7RA11BU 8A RE7RM11BU 2 C/O contacts 8A RE7RL13BU 1 solid state output 0.7 A RE9RA11MW7 0.3 s...30 s 0.7 A RE9RA31MW7 3 s...300 s 0.7 A RE9RA21MW7 40 s...60 min 0.7 A RE9RA51MW7 1 s...100 h 0.7 A RE17LCBM 8A RE7CL11BU 0.05 s...300 h a/c 24 V, a 110...240 V 1 C/O contact 0.1 s...10 s H 8A 8A RE8CL11BUTQ 0.05 s...300 h a/c 24 V, a 110...240 V, 2 C/O contacts a/c 42...48 V 8A RE7CP13BU 0.05 s...300 h a/c 24 V, a 110...240 V 1 C/O contact 8A RE7PE11BU 0.1 s...10 s 8A RE8PE11BUTQ 0.3 s...30 s 8A RE8PE31BUTQ 3 s...300 s 8A RE8PE21BUTQ a/c 24 V, a 110...240 V, 2 C/O contacts a/c 42...48 V 8A RE7PP13BU RE17LHBM 0.05 s...300 h 1 s...100 h a 24...240 V 1 solid state output 0. 7 A H, Ht 1 s...100 h c 24 V, a 24...240 V 1 C/O contact 8A RE17RHMU He 0.05 s...0.5 s a/c 24 V, a 110...240 V 1 C/O contact 8A RE8PT01BUTQ K 0.05 s...10 min a/c 24...240 V 1 C/O contact 5A RE7RB11MW 0.05 s...0.5 s a/c 24 V, a 110...240 V 1 C/O contact 8A RE8RB51BUTQ 0.1 s...10 s 8A RE8RB11BUTQ 0.3 s...30 s 8A RE8RB31BUTQ L, Li L, Li, Lt Qc Qe 0.05 s...10 min a/c 24...240 V 2 C/O contacts 5A RE7RB13MW 1 s...100 h c 24 V, a 24...240 V 1 C/O contact 8A RE17RLMU 1 s...100 h a 24...240 V 1 solid state output 0.7 A RE17LLBM 1 s...100 h a/c 12 V 1 C/O contact 8A 0.02 s...300 h a/c 24...240 V 2 timed C/O contacts 5 A 0.05 s...300 h a 110...240 V, a/c 24 V, 1 C/O contact a/c 42...48 V 8A RE7CV11BU 0.1 s...10 s a/c 24 V, a 110...240 V 1 C/O contact 8A RE8YG11BUTQ RE17RLJU RE48ACV12MW 0.3 s...30 s 8A RE8YG31BUTQ 3 s...300 s 8A RE8YG21BUTQ 0.3 s...30 s a/c 24 V 1 NO + 1 NC 8A RE8YA32BTQ 0.3 s...30 s a 110...240 V 1 NO + 1 NC 8A RE8YA32FUTQ 0.3 s...30 s a 380...415 V 1 NO + 1 NC 8A RE8YA32QTQ Qg 0.05 s...300 h a/c 24 V, a 110...240 V, 1 NO + 1 NC a/c 42...48 V 8A RE7YR12BU Qt 0.05 s...300 h a/c 24 V, a 110...240 V, 2 C/O contacts a/c 42...48 V 8A RE7YA12BUe+ W 0.1 s...10 s a/c 24 V 1 C/O contact 0.3 s...30 s 3 s...300 s 0.1 s...10 s W, Ht 28400-EN version: 2.0 a 110...240 V 1 C/O contact 8A RE8PD11BTQ 8A RE8PD31BTQ 8A RE8PD21BTQ 8A RE8PD11FUTQ 0.3 s...30 s 8A RE8PD31FUTQ 3 s...300 s 8A RE8PD21FUTQ 0.05 s...300 h a/c 24 V, a 110...240 V, 2 C/O contacts a/c 42...48 V 8A RE7PD13BU 0.05 s...300 h a/c 24 V, a 110...240 V, 1 C/O contact a/c 42...48 V 8A RE7PM11BU 5 Functions Zelio Time - timing relays Functions U: Supply R: Relay or solid state output R1/R2: 2 timed outputs R2 inst.: The second output is instantaneous if the right position is selected T: Timing period C: Control contact G: Gate Ta: Adjustable On-delay Tr: Adjustable Off-delay Function diagram : Relay de-energized Relay energized Output open Output closed Function A: Power on delay relay 1 output 2 outputs The timing period T begins on energization. After timing, the output(s) R close(s). The second output can be either timed or instantaneous. U U R R1/R2 T R2 inst. T 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.). Function Ac: On-delay and off-delay relay with control signal 1 output 2 outputs U U C C G R1/R2 R2 inst. R t1 t2 t'1 T t'2 T After power-up, closing of the control contact C causes the timing period T to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period, the relay closes. When control contact C re-opens, the timing T starts. At the end of this timing period T, the output reverts to its initial position (timing can be interrupted by operating the Gate control contact G). The second output can be either timed or instantaneous. 2 timed outputs (R1/R2) or 1 timed output T = t1 + t2 + ... (R1) and 1 instantaneous output (R2 inst.). T = t'1 + t'2 + ... Function Ad: Pulse delayed relay with control signal After power-up, pulsing or maintaining control contact C starts the timing T. At the end of this timing period T, the output R closes. The output R will be reset the next time control contact C is pulsed or maintained. U C R T T Function Ah: Pulse delayed relay (single cycle) with control signal After power-up, pulsing or maintaining control contact C starts the timing T. A single cycle then starts with 2 timing periods T of equal duration (start with output in rest position). Output R changes state at the end of the first timing period T and reverts to its initial position at the end of the second timing period T. Control contact C must be reset in order to re-start the single flashing cycle. U C R T 6 T T T 28400-EN version: 2.0 Functions (continued) Zelio Time - timing relays Functions (continued) Function Ak: Asymmetrical On-delay and Off-delay with external control After power-up and closing of the control contact C, timing starts for a period Ta (timing can be interrupted by operating the Gate control contact G). At the end of this timing period Ta, the output R closes. Opening of control contact C causes a second timing period Tr to start (timing can be interrupted by operating the Gate control contact G). At the end of this timing period Tr, the output R reverts to its initial state. U C G R t1 t2 t'1 t'2 Ta = t1 + t2 + ... Tr = t'1 + t'2 + ... Function At: Power on delay relay (summation) with control signal After power-up, the first opening of control contact C starts the timing. Timing can be interrupted each time control contact C closes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output relay closes. U C R t1 t2 T = t1 + t2 + ... Function Aw: Off-delay on energization or on opening of control contact The timing period T starts on energization. At the end of the timing period T, the output R closes. Closing of the control contact C makes the output R open. Opening of control contact C restarts timing period T. At the end of the timing period T, the output R closes. U C R T T Function B: Interval relay with control signal After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then reverts to its initial state. U C R T T Function Bw: Double interval relay with control signal On closing and opening of control contact C, the output R closes for the duration of the timing period T. U C R T 28400-EN version: 2.0 T 7 Functions (continued) Zelio Time - timing relays Functions (continued) Function C:Off-delay relay with control signal 1 output 2 outputs U U C C R After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. R1/R2 T R2 inst. T 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.). Function D: Symmetrical flasher relay (starting pulse off) 1 output 2 outputs Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T. The second output can be either timed or instantaneous. U U R1/R2 R T T T T T T R2 inst. T T T T T T 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.). Function Di: Symmetrical flasher relay (starting pulse on) 1 output 2 outputs U Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T. The second output can be either timed or instantaneous. U R1/R2 R T T T T T R2 inst. T T T T T 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.). Function H: Interval relay 1 output 2 outputs On energization of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. U U R1/R2 R T R2 inst. T 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.). 8 28400-EN version: 2.0 Functions (continued) Zelio Time - timing relays Functions (continued) Function He: Pulse-on de-energization On de-energization, the output R closes for the duration of a timing period T. U R > 80 ms T 80 ms