- Electrostatic Discharge
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
Capacitor: 220 µF / 100 V
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 3 A/m, perf. criteria A
95% max. (non condensing)
Natural convection (20 LFM)
- Current Controlled Remote
On: open circuit
Off: 2 to 4 mA current
Altitude During Operation
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
6'430'000 h (MIL-HDBK-217F, ground benign)
Moisture Sensitivity (MSL)
Not allowed (non-hermetical product)
Non-conductive Plastic (UL94 V-0 rated)
Reflow Soldering (J-STD-020E)
SMD (Surface-Mount Device)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Overview Link (for additional Documents)
www.tracopower.com/overview/tmr2wism