www.recom-power.com REV.: 4/2019 ECO-4
DC/DC Converter
Specifi cations (measured @ Ta= 25°C, nominal input voltage, full load unless otherwise specifi ed)
R1DX
Series
SAFETY AND CERTIFICATIONS
Certifi cate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E224736 UL60950-1, 2nd Edition 2014
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition 2014
Information Technology Equipment, General Requirements for Safety (CB Scheme) E224736-4788277362-2 IEC60950-1:2005 2nd Edition + A2:2013
Information Technology Equipment, General Requirements for Safety EN60950-1:2006 + A2:2013
Audio/video, information and communication technology equipment - Safety requirements
(LVD) E224736 UL62368, 2nd Edition, 2014
CAN/CSA -C22.2 No. 62368-1-14, 2nd Edition, 2014
Audio/video, information and communication technology equipment - Safety requirements
E224736-4788277362-1
EN62368-1:2014 + A11:2017
Audio/video, information and communication technology equipment - Safety requirements
(CB Scheme) IEC62368-1:2014 2nd Edition
RoHS2+ RoHS 2011/65/EU + AM2015/863
EMC Compliance Condition Standard / Criterion
Information technology equipment - Radio disturbance characteristics - Limits and meth-
ods of measurement
with external fi lter
(see fi lter suggestion)
EN55032:2015, Class A and B
Information technology equipment - Immunity characteristics Limits and methods of
measurement EN55024:2010 +A1:2015
ESD Electrostatic discharge immunity test
Air: ±2, 4, 6, 8kV
Contact: ±2, 4kV
IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic fi eld immunity test
3 V/m
IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity
±0.5kV
IEC61000-4-4:2012, Criteria A
Surge Immunity
±0.5kV
IEC61000-4-5:2014, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fi elds
3V r.m.s.
IEC61000-4-6:2013, Criteria A
Power Magnetic Field Immunity
50Hz / 1A/m
IEC61000-4-8:2009, Criteria A
continued on next page
Derating Graph
(@ Chamber and natural convection 0.1m/s)
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
95
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]