L Series
Power Inlet Filters & Power Entry Modules
L Series
Dual Configuration Power Entry Module
3
175
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
UL Recognized
CSA Certified
VDE Approved
Ordering Information
6 E D L 1 S C M
Fuseholder Type (pre-installed)
M – Metric
Omit for North American
Mounting Type
C– Snap-In
Omit for flange mount
Switch Option
S – DPST on/off switch
Omit for none
Voltage Selection Positions
1 or 4
L Series
Filter Type
D – General Purpose
H – Medical
omit for none
Leakage current designation
E – Low Leakage (<0.5 mA)
Current Rating
2, 4 or 6A
EDL1S / EHL1S
Maximum leakage current each Line to Ground:
DL Models HL Models
@ 120 VAC 60 Hz: .25 mA 2 A
@ 250 VAC 50 Hz: .50 mA 5 A
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Operating Voltage:
1S & 1SC models (fixed): 250 VAC max.
4 & 4C Suffix: 100, 120, 220 or 240 VAC.
Operating Frequency: 50/60 Hz
Rated Current: 2 to 6A
Required Fuse(s):
North American: one .25 x 1.25”(not included)
Metric: two 5 x 20mm (not included)
Switch: DPST
10,000 operations at 51A max. inrush
Specifications
EDL4C / EHL4C
• Power entry module with switch or fuse
• For 10A capability and high performance filtering
see the P Series on page 192
• Two element circuit provides extended EMI
attenuation similar to EAB inlet filter
• North American or metric fuse holders
• Available with minimal leakage current for medical
applications (HL models)
176
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
North American Fusing Metric Fusing
Flange Mount Snap-In Flange Mount Snap-In
Non-Filtered
Single Voltage,
Switched 6EL1S 6EL1SC 6EL1SM 6EL1SCM
4 Voltage Select,
No Switch 6EL4 6EL4C 6EL4M 6EL4CM
General
Purpose Filter
Single Voltage,
Switched
2EDL1S 2EDL1SC 2EDL1SM 2EDL1SCM
4EDL1S 4EDL1SC 4EDL1SM 4EDL1SCM
6EDL1S 6EDL1SC 6EDL1SM 6EDL1SCM
4 Voltage Select,
No Switch
2EDL4 2EDL4C 2EDL4M 2EDL4CM
4EDL4 4EDL4C 4EDL4M 4EDL4CM
6EDL4 6EDL4C 6EDL4M 6EDL4CM
Medical Filter
Single Voltage,
Switched 6EHL1S 6EHL1SC 6EHL1SM 6EHL1SCM
4 Voltage Select,
No Switch 6EHL4 6EHL4C 6EHL4M 6EHL4CM
L Series
Dual Configuration Power Entry Module (continued)
Available Part Numbers
Voltage Selection
To change selected voltage: disconnect the power
cord; open cover using a small blade screwdriver or
similar tool; insert the tool into the voltage selection
slot and remove wheel from unit; select desired
voltage; replace wheel into unit and close cover,
making sure the selected voltage appears in
connector window.
Recommended Panel Cutouts
.06
1.52 R
2.201
55.91
2.213*
56.21
1.122
28.50
1.575
40.00
.020
.508 R
*
*
*+.008 -.00
+.203 -.00
(1)
(2)
(3)
(4)
(3) (3)
 





L Series
Dual Configuration Power Entry Module (continued)
Power Inlet Filters & Power Entry Modules
3
177
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Electrical Schematics
DL Models
Hot
Neutral Note 1 H
Ground
G
On/O
2
(1) 1
(1a)
(2)
4(2a)
3
Note 2
Device
Customer
Transformer
Primaries
4 Voltage Select, No-Switch (DL4)
Hot
Neutral
Note 1 G
Ground
H
On/O
Note 2
Customer
Transformer
Primaries
100V
120V
100V
20V
120V
220V
240V
AA
BB
CC
DD
EE
FF
A
B
C
D
E
F
 
 
Single Voltage, Switched (DL1S)
HL Models
Hot
Neutral Note 1 H
Ground
G
On/O
2
(1) 1
(1a)
(2)
4(2a)
3
Note 2
Device
Customer
Transforme
r
Primaries
4 Voltage Select, No-Switch (HL4)
Hot
Neutral
Note 1 G
Ground
H
On/O
Note 2
Customer
Transformer
Primaries
100V
120V
100V
20V
120V
220V
240V
AA
BB
CC
DD
EE
FF
A
B
C
D
E
F
Single Voltage, Switched (HL1S)
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Accessories
LA601: Insulating Boot
Plastic shroud to cover back of module to prevent
inadvertent access
LA200: North American Fuseholder
Accommodates one .25 x 1.25” fuse
LA201: Metric Fuseholder
Accommodates one 5 x 20mm metric fuse
LA303: Voltage Select Wheel, 3 position
Selection drum for use with L4 models.
Marked with 110V, 220V and 240V
LA304: Voltage Select Wheel, 4 position
Selection drum for use with L4 models.
Marked with 100V, 110V, 220V and 240V.
One LA304 comes standard with each L4 model.
LA400: Blank insert
Blank to replace switch in single voltage models
Replacement Fuse Holders
L Series
Dual Configuration Power Entry Module (continued)
178
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Case Styles
Flange Models, Non-filtered
GH
3
1
4
2
B
AE
.221
5.61
F
C D


 
 
 
Flange Models, Filtered
B
A
F
E
.221
5.61
C D
GH
2
4
3
1

 

 
 
 
Snap-in Models, Non-filtered
A
ACE
BDF
GH
E
.221
5.61
F
C D


 
 
 
Snap-in Models, Filtered
A
E
.221
5.61
F
C D
ACE
BDF
GH

 

 
 
 
ABCDEF
Model No.  
    
Flange
Unfiltered
     
     
Snap-in
Unfiltered
    
    
Flange
Filtered
     
     
Snap-in
Filtered
    
    
Case Dimensions
L Series
Dual Configuration Power Entry Module (continued)
Power Inlet Filters & Power Entry Modules
3
179
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
2EDL 4EDL 6EDL
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
00.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Measured in closed 50 Ohm system
    
    
 
     
    
    
 
    
Differential Mode / Symmetrical (Line to Line)
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
6EHL
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
    
    
 
      
      
      
 
    