DataSheet
Solid State Relay Timer
SeriesOneDR Timer
6 Amp AC and DC rated output
Compact size (11mm wide)
Dual SCR or MOSFET output
AC/DC control
Zero-crossing (resistive loads) or random-fire (inductive loads) AC output
Timer status LED indicator
UL listed, HP rated
8 Industry standard fuctions (A/At, B, C, D/Di, H/Ht, L/Li, Ac and Bw)
PRODUCT SELECTION
Control Voltage DC OutputAC Output
12-24 VAC/DC DRTx24D06x DRTx06D06
90-140 VAC/DC DRTx24B06x
180-280 VAC/DC DRTx24A06x
AVAILABLE OPTIONS
DRT
Series
Operating Voltage
06: 60 VDC
24: 280 VAC
Rated Load Current
06: 6 Amps
Control Voltage
D: 12-24 VAC/DC
A: 180-240 VAC/DC
B: 90-140 VAC/DC
Timing Function
A: A/At, Delay on Make
B: Single Shot
C: Delay on Break
H: H/Ht, Interval
L: L/Li, Repeat Cycle
U: Multifunction
(A/At, H/Ht, D/Di,
B, C, Ac & Bw)
Switching Type
(24 suffix only)
Blank: Zero Voltage Turn-On
R: Random Turn-On
0624 DA R
AC
Output
Only
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS
(1)
DRTx06DRTx24Description
Operating Voltage 24-280 VAC (47-440Hz) 1-48 VDC
Transient Overvoltage [Vpk] 600 60 VDC
Rated Load Current
(2)
6 Arms 6 A
Rated Load Current {UL508 Motor Controller}
(2)
[Arms] 3.6 Arms -
Minimum Load Current 150 mArms 2.5 mA
Maximum Off-State Leakage Current @ Rated Voltage 0.1 mArms 0.25 mA
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
(3)
500 -
Maximum Surge Current (AC output 1 cycle. DC output 10ms) 285/300 Apk (50/60Hz) 60 A
Maximum I²t for Fusing [A² sec] 410/375 (50/60Hz) -
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.3 0.3 VDC
Maximum On-State Resistance (RDS-ON) [Ohms] - 0.034
HP rating UL 508/IEC60947[HP (KW)]: 240 VAC 1/3 (0.24) -
IEC 62314 LC-A [FLA] 6 A -
IEC 62314 LC-B [Kw] 0.24 -
Wire Size min/max (solid/stranded) [AWG/ IEC mm²]
(4)
22/12 [0.33/3.31] 22/12 [0.33/3.31]
Output Terminal Screw Torque [in lb (Nm)] 7.0 (0.8) 7.0 (0.8)
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Not all part number combinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
*
DataSheet
Solid State Relay Timer
INPUT SPECIFICATIONS
(1)
DRTx24B06DRTx24A06DRTxxxD06Description
Control Voltage Range 12-24 VAC/DC 180-280 VAC/DC 90-140 VAC/DC
Must Turn-Off Voltage 1 VAC/DC 20 VAC/DC 10 VAC/DC
Min Input Current @ Min Voltage (AC/DC) (for on-state) 7.6/6.3 mA
(5)
7.2/7.1 mA 7.6/7.4 mA
Maximum Input Current @ Maximum Voltage 12.1/9.1 mA
(6)
9.7/9.6 mA 12.5/12.3 mA
Nominal Input Impedance 2K (7) 25K 12K
Wire Size min-max (solid/stranded) [AWG/ IEC mm²]
(4)
22-16 / 0.33-1.31 22-16 / 0.33-1.31 22-16 / 0.33-1.31
LED Status Indicator (Color) Yes (green) Yes (green) Yes (green)
Input Terminal Screw Torque [in lb (Nm)] 4.4 (0.5) 4.4 (0.5) 4.4 (0.5)
Maximum turn-on/off time See note
(9)
See note
(9)
See note
(9)
GENERAL SPECIFICATIONS
ParametersDescription
Dielectric Strength, Input/Output/Base (50/60Hz) 3750 Vrms
(8)
Minimum Insulation Resistance (@ 500 VDC) 109 Ohm
Maximum Capacitance, Input/Output 10 pF
Ambient Operating Temperature Range -30 to 80 °C
Ambient Storage Temperature Range -40 to 125 °C
Weight (typical) 1.76 oz (50 g)
Housing Material UL 94 V0 Self-extinguishing
Terminal Finish Sulfamate Nickel
Humidity 5 - 85% Non condensing
RoHS Exemption #’s 5(a), 7(a), 7(c)-I
WIRING DIAGRAM
INPUT
CONTROL
Load
Y1
+3/A1
4/A2
+1/L1
2/T1
AC Output
TIMER
Status
Indicator
(+ / )
(– / )
( )
( )
(10)
INPUT
CONTROL
Load
Y1
+3/A1
4/A2
+1/L1
2/T1
DC Output
TIMER
Status
Indicator
(+ / )
(– / )
( + )
( – )
Load
Load T1
A2
A1
Y1
L1
AC/DC CONTROL
VOLTAGE
(Input)
AC/DC SUPPLY
(OUTPUT)
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
DataSheet
Solid State Relay Timer
TIMER SETTINGS & RANGES
Timer Settings
Identification
Timing
Function
U
Multifunction
[A/At, H/Ht, D/Di,
B, C, Ac, Bw]
L
Repeat Cycle
A
Delay on Make
H
Interval
B
Single Shot
C
Delay on Break
10
1
2
8
7
6
5
4
3
9
10
1
2
8
7
6
5
4
3
9
10
1
2
8
7
6
5
4
3
9
10
1
2
8
7
6
5
4
3
9
INPUT
STATUS
10h
10m
1h
100h
1s
10s
1m
Ac
C
Di
Bw
A
H
B
10h
10m
1h
100h
1s
10s
1m
10h
10m
1h
100h
1s
10s
1m
10h
10m
1h
100h
1s
10s
1m
Range Function Fine Adjustment
Fine Adjustment
Fine Adjustment
Range
Flat side indicates selection
Front ViewSide View
T on T off
1s
10 s
1 min
10 min
1 h
10 h
100 h
0.1 s to 1 s
1 s to 10 s
0.1 min to 1 min
1 min to 10 min
0.1 h to 1 h
1 h to 10 h
10 h to 100 h
Timing Ranges
(11)
Identification Timing Range
GENERAL NOTES
(1) All parameters at 25°C unless otherwise specified.
(2) See derating curves.
(3) Off-State dv/dt test method per EIA/NARM standard RD-443, paragraph 13.11.1
(4) For UL Listing, must use wire rated @ 75°C.
(5) For DC output model minimum current spec is 15.7/12.4ma (AC/DC).
(6) For DC output model maximum current spec is 27.9/20.3ma (AC/DC).
(7) For DC output mode, spec is 1K.
(8) For DC output model, spec is 2500V.
(9) Activation Time = 65ms / Deactivation Time = 100 ms.
(10) Inductive loads must be diode suppressed to prevent damage to output.
(11) Timing accuracy ± 10%. Additional functions and time ranges are also available,
please contact your local authorized Crydom Distributor, Representative or Crydom
Sales office and request information about our custom products.
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
DataSheet
Solid State Relay Timer
MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
3.27
[83.0]
3.45
[87.7]
2.59
[65.9]
1.76
[44.8]
3.44
[87.3]
2.02
[51.2]
0.44
[11.0]
2.87
[73.0]
INPUT 12-24 VDC
General Use 60VDC/6Arms
@40°C Ambient Temperature
IND. CONT. EQ
INPUT
STATUS
4/A2 2/T1
Y1
DRTL06D06
+1/L1
+3/A1
4WB8
SOLID STATE TIMER
THERMAL DERATE INFORMATION
5
3
6
4
2
1
0 302010 40 50 60 70 80
0
Ambient Temperature (ºC)
Load Current (Amps)
Installed single unit, distance to adjacent components ≥ 11 mm
Multiple Units No Spacing
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
DataSheet
Solid State Relay Timer
T
C
L
A
T
C
L
H
T
C
L
Y1
B
T
C
L
T T T T
Di
C
L
Y1 TT
Ac
T=t1+t2+t3
Y1
L
t1 t2 t3
At
C
T=t1+t2+t3
C
L
t1 t2 t3
Y1
Ht
T
C
L
Y1
C
T
C
L
TTTT
A1Y1
D
C
L
Y1
T
T
Bw
C
L
A1Y1 Ton Toff Ton Toff
Toff
LTon
C
L
Toff Ton Toff
Li
LED Status by Function
Function Control Voltage Y1 Timing Output State LED Status Notes
A/At
Delay On Make
Off
On
On
Off
On
On
On
Off
On
On
On
On
Off
On
On
On
Off
On
On
On
On
On
Off
On
Off
On
Off
On
On
Open
Open
Closed
Closed
Open
Open
Closed
Open
Open
Open
Open
Closed
Closed
Open
Open
Closed
Closed
Open
Open
Off
On
Timed Out
Off
Off
On
Timed Out
Off
Off
Off
On
Timed Out
Off
Off
On
Timed Out
Off
Off
On
Timed Out
On
Timed Out
Off
On
Off
On
Off
On
Timed Out
Off
Off
On
Off
Off
On
Off
Off
Off
On
On
Off
Off
Off
Off
On
Off
Off
On
Off
On
Off
Off
On
Off
On/Off
Off
On/Off
Off
Off
Long Flashes
On
Off
Short Flashes
Long Flashes
Short Flashes
Off
Short Flashes
On
Long Flashes
Short Flashes
Off
Short Flashes
Long Flashes
On
Off
Short Flashes
Long Flashes
Short Flashes
Long Flashes
Short Flashes
Off
Long Flashes
Off
Long Flashes/Short Flashes
Off
Long Flashes/Short Flashes
Short Flashes
H/Ht
Interval
D/Di
Repeat Cycle
L/Li
Repeat Cycle
B
Single Shot
C
Delay On Break
Ac
Delay On Make /
Delay On Break
Bw
At function is identical to the A function except when Y1 is connected to A1 timing is paused. When Y1 is
removed timing resumes until relay times out. To reset timer remove control power.
Ht function is identical to the H function except when Y1 is connected to A1 timing is paused. When Y1 is
removed timing resumes until relay times out. To reset timer remove control power.
Y1 switch can be momentary or maintained to A1. To
reset timer after relay has timed out Y1 has to be
opened.
Y1 switch to A1 must be momentary for timing to
begin. If during timing Y1 is closed again the time
delay is reset and will begin again once Y1 is
removed. Once timed out timer is reset and ready for
the next cycle.
Y1 to A1 switch can be momentary or maintained. If
maintained until relay has timed out removing it will
start timing again. If momentary and timers has
timed out reapplying Y1 will start timing again.
To start Delay on Make (A) timing connect Y1 to A1
and maintain until LED is on Solid then to start Delay
on Break (c) portion remove Y1 until relay times out.
Removing Y1 During (A) portion or Connecting Y1
during (c) portion will reset time for that portion.
To select between on time (Di) first or off time (D) first Y1 is connected. Default is On time (Di) first, for Off
time (D) first connect Y1. Equal On/Off time.
To select between on time (Li) first or off time (L) first Y1 is connected A1. Default is On time (Li) first, for Off
time (L) first connect Y1 to A1. Time delay is independent of each other.
LED STATUS FUNCTION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
IEC 60068-2-6 : Vibration 0.35mm and 0.75mm Amplitutde over 10-55 Hz
IEC 60068-2-27 : Shock 15G/11ms
IEC 61000-4-2 : Electrostatic Discharge Level 3
IEC 61000-4-4 : Electrically Fast Transients Level 3
IEC 61000-4-5 : Electrical Surges Level 3
E116949
093013
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
IND. CONT. EQ.
4WB8
DataSheet
Solid State Relay Timer
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
Disconnect all
power before
installing or
working with
this equipment.
Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSI
ONE.
Spenga tutta
l'alimentazion
e che fornisce
questa
apparecchiatu
ra prima del
lavorare a questa
apparecchiatu ra
Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima della
rotazione
sull'alimentazi one
L'omissione di
seguire queste
istruz ioni
provocherà la
morte o di
lesioni serie
存在电击、
爆炸或电弧
闪烁危险
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
The product's side panels may be hot, allow
the product to cool before touching.
Follow proper mounting instructions including
torque values.
Do not allow liquids or foreign objects to enter
this product.
Failure to follow these instructions can result in
serious injury, or equipment damage.
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
Respecter les consignes de montage, et
notamment les couples de serrage.
Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
Le non-respect de cette directive peut entraîner,
des lésions corporelles graves ou des
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
Beachten Sie die Montageanweisungen,
Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
Respetar las instrucciones de montaje, y en
particular los pares de apretado.
No dejar que penetren líquidos o cuerpos
extraños en el producto.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
Seguire le istruzioni di montaggio corrette.
Non far entrare liquidi o oggetti estranei in questo
apparecchio.
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
材料损坏和高温外壳的危险性
产品的一侧面板可能很热,在其冷却前请
不要触碰。
遵照正确的安装说明,包括扭矩值。
请勿让液体及其他异物进入本产品。
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
DataSheet
Solid State Relay Timer
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated
(Pb) (Hg) (Cd) Chromium
(Cr (VI))
biphenyls
(PBB)
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
有毒有害物质或元素
名称 六价铬 多溴联苯 多溴二苯醚
(Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE)
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Crydom:
DRTH24B06 DRTA24B06R DRTL24D06R DRTH24D06R DRTU24D06 DRTU24A06R DRTB06D06 DRTA24D06
DRTC24A06 DRTL06D06 DRTH24B06R DRTU24B06 DRTC24B06R DRTB24B06R DRTB24A06 DRTU24B06R
DRTL24B06 DRTH06D06 DRTC24D06 DRTB24A06R DRTH24A06R DRTU06D06 DRTL24B06R DRTB24D06
DRTA24A06R DRTH24A06 DRTC24D06R DRTC06D06 DRTC24B06 DRTC24A06R DRTA24A06 DRTU24A06
DRTA24D06R DRTA24B06 DRTL24D06 DRTL24A06R DRTL24A06 DRTA06D06 DRTB24D06R DRTB24B06
DRTH24D06 DRTU24D06R