11-6 Industrial Circuit Breakers January 2001 Vol. 1, Ref. No. [0438] QUICKLAG -- Bolt-On Ground Fault and Equipment Protectors Bolt-On Types BAB, QBHW, HBAX, HBAW Product Selection Table 11-6. Breaker Catalog Numbers Continuous Ampere Rating @ 40C 1-Pole 120/240V AC Catalog Number Price U.S. $ 2-Pole 120/240V AC Catalog Price Number U.S. $ 240V AC Catalog Number Price U.S. $ 3-Pole 240V AC Catalog Number Price U.S. $ 156.00 156.00 156.00 156.00 156.00 156.00 156.00 156.00 156.00 156.00 156.00 206.00 239.00 239.00 239.00 -- -- BAB3010H BAB3015H BAB3020H BAB3025H BAB3030H BAB3035H BAB3040H BAB3045H BAB3050H BAB3055H BAB3060H BAB3070H BAB3080H BAB3090H BAB3100H -- -- 193.00 193.00 193.00 193.00 193.00 193.00 193.00 193.00 193.00 193.00 193.00 240.00 274.00 274.00 274.00 -- -- 215.00 215.00 215.00 215.00 215.00 215.00 215.00 215.00 215.00 215.00 257.00 290.00 290.00 290.00 -- -- QBHW3015H QBHW3020H QBHW3025H QBHW3030H QBHW3035H QBHW3040H QBHW3045H QBHW3050H QBHW3055H QBHW3060H QBHW3070H QBHW3080H QBHW3090H QBHW3100H -- -- 289.00 289.00 289.00 289.00 289.00 289.00 289.00 289.00 289.00 289.00 418.00 418.00 418.00 448.00 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- HBAX3015H HBAX3020H HBAX3025H HBAX3030H HBAX3035H HBAX3040H HBAX3045H HBAX3050H HBAX3055H HBAX3060H HBAX3070H HBAX3080H HBAX3090H HBAX3100H 347.00 347.00 347.00 347.00 347.00 347.00 347.00 347.00 347.00 347.00 424.00 590.00 590.00 530.00 -- -- -- -- HBAW3015H HBAW3020H -- -- 350.00 350.00 -- -- QUICKLAG Type: BA 10,000 Ampere I.C. Thermal-Magnetic Breakers QUICKLAG Type BA 1-Pole Product Description Built and listed to UL 489 All products UL and CSA listed All products 15 - 100A are HACR rated Switching duty rated for 120V AC fluorescent light applications 11 Dimension Sheets -- FRED Index 206 10 15 20 25 30 35 40 45 50 55 60 70 80 90 100 110 125 27.50 27.50 27.50 27.50 27.50 27.50 27.50 27.50 27.50 27.50 27.50 53.50 -- -- 91.00 -- -- BAB1010 BAB1015 BAB1020 BAB1025 BAB1030 BAB1035 BAB1040 BAB1045 BAB1050 BAB1055 BAB1060 BAB1070 -- -- BAB1100 -- -- BAB2010 BAB2015 BAB2020 BAB2025 BAB2030 BAB2035 BAB2040 BAB2045 BAB2050 BAB2055 BAB2060 BAB2070 BAB2080 BAB2090 BAB2100 BAB2110 BAB2125 60.50 60.50 60.50 60.50 60.50 60.50 60.50 60.50 60.50 60.50 60.50 115.00 156.00 156.00 156.00 332.00 332.00 BAB2010H BAB2015H BAB2020H BAB2025H BAB2030H BAB2035H BAB2040H BAB2045H BAB2050H BAB2055H BAB2060H BAB2070H BAB2080H BAB2090H BAB2100H -- -- QUICKLAG Type: QBHW 22,000 Ampere I.C. Thermal-Magnetic Breakers 15 20 25 30 35 40 45 50 55 60 70 80 90 100 110 125 QBHW1015 QBHW1020 QBHW1025 QBHW1030 QBHW1035 QBHW1040 QBHW1045 QBHW1050 QBHW1055 QBHW1060 QBHW1070 -- -- -- -- -- 54.50 54.50 54.50 54.50 54.50 54.50 54.50 54.50 54.50 54.50 72.50 -- -- -- -- -- QBHW2015 QBHW2020 QBHW2025 QBHW2030 QBHW2035 QBHW2040 QBHW2045 QBHW2050 QBHW2055 QBHW2060 QBHW2070 QBHW2080 QBHW2090 QBHW2100 QBHW2110 QBHW2125 117.00 117.00 117.00 117.00 111.00 117.00 117.00 117.00 117.00 117.00 170.00 253.00 253.00 253.00 735.00 735.00 QBHW2015H QBHW2020H QBHW2025H QBHW2030H QBHW2035H QBHW2040H QBHW2045H QBHW2050H QBHW2055H QBHW2060H QBHW2070H QBHW2080H QBHW2090H QBHW2100H -- -- QUICKLAG Type: HBAX 42,000 Ampere I.C. Thermal-Magnetic Breakers 15 20 25 30 35 40 45 50 55 60 70 80 90 100 HBAX1015 HBAX1020 HBAX1025 HBAX1030 HBAX1035 HBAX1040 HBAX1045 HBAX1050 HBAX1055 HBAX1060 HBAX1070 -- -- -- 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 77.00 124.00 -- -- -- HBAX2015 HBAX2020 HBAX2025 HBAX2030 HBAX2035 HBAX2040 HBAX2045 HBAX2050 HBAX2055 HBAX2060 HBAX2070 HBAX2080 HBAX2090 HBAX2100 139.00 139.00 139.00 139.00 139.00 139.00 139.00 139.00 139.00 139.00 211.00 295.00 295.00 295.00 -- -- -- -- -- -- -- -- -- -- -- -- -- -- QUICKLAG Type: HBAW 65,000 Ampere I.C. Thermal-Magnetic Breakers 15 20 25 30 HBAW1015 HBAW1020 HBAW1025 HBAW1030 87.50 87.50 87.50 87.50 HBAW2015 HBAW2020 HBAW2025 HBAW2030 200.00 200.00 200.00 200.00 -- -- -- -- Switching duty rated for 120V AC fluorescent light applications. For special low-magnetic breaker order BAB1015L1 or BAB1020L1. Technical Data and Specifications Table 11-7. Shipping Data Number Carton of Poles Quantity Approximate Weight Lbs. (Kg) Dimensions in Inches (mm) Time/Current Curves 1 2 3 9.00 (4.1) 9.00 (4.1) 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0) FRED 350077 FRED 350177 FRED 350277 24 12 8 Note: Dimension Sheets -- FRED Index 206 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-1 For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E 11-2 Industrial Circuit Breakers January 2001 Vol. 1, Ref. No. [0434] QUICKLAG(R) Contents 11 Description Page Description Quick Reference . . . . . . . . . . . . Plug-On Types HQP, QPHW, QHPX, QHPW . . . . . . . . . . . . . . . . . . . Plug-On Ground Fault and Equipment Protectors Types QPGF, QPHGF, QPGFEP, QPHGFEP. . . . . . . . . Bolt-On Types BAB, BABR, QBHW, HBAX, HBAW . . . . . . . . . . . . . Bolt-On Ground Fault and Equipment Protectors Types QBGF, QBHGF, QBGFEP, QBHGFEP . . . . . . . . Cable-In/Cable-Out Types QC, QCHW, QHCX, QHCW . . . . . . . . . . . . . . . . . . . 11-2 Cable-In/Cable-Out, 1/2 Wide Types QCR, QCF, QCRH, QCFH . . . . . . . . . . . . . . . . . . . 11-10 Cable-In/Cable-Out Ground Fault and Equipment Protectors Types QCGF, QCHGF, QCGFEP, QCHGFEP . . . . . . . . . . . . . . . 11-13 Solenoid-Operated, RemoteControlled Types GHBS, GBHS, BABR . 11-14 International Rated Types HQP, BA, QC, GFXB, GFXBB, GFXBC . . . . . . . . . . . 11-16 Special Application Breakers Types HQP, BA, QC . . . . . . . . 11-18 Options and Accessories . . . . 11-20 Factory Modifications and Installed Terminals . . . . . . . . 11-22 11-4 11-5 11-6 11-7 11-8 Page Quick Reference Table 11-1. QUICKLAG Industrial Circuit Breakers Plug-In, Bolt-On, Cable-In/Cable-Out Circuit Breaker Type Circuit Breaker Type Code HQP HQP HQP P QPHW QPHW QPHW P QHPX QHPX QHPX P QHPW QHPW QHPW P QPGF QPGF Continuous Number Ampere of Poles Rating @ 40C AC 10 - 70 10 - 125 10 - 100 1 2 2, 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- 15 - 70 15 - 125 15 - 100 1 2 2, 3 120/240 120/240 240 15 - 70 15 - 100 15 - 100 1 2 3 15 - 30 15 - 30 15 - 20 P, GF QPHGF QPHGF QPGFEP QPGFEP Volts DC Federal Spec. W-C-375b Interrupting Ratings rms Symmetrical Amperes 120/240 240 24-48 62.5 10a, 11a, 12a -- 10a, 12a -- 10b, 11b, 12b -- 10,000 10,000 -- -- -- 10,000 5,000 5,000 -- 5,000 -- 24, 48, 62.5 24, 48, 80 -- 14a 14a 14b -- -- -- 22,000 22,000 -- -- -- 22,000 5,000 5,000 -- 5,000 -- 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- - - - -- -- -- 42,000 42,000 -- -- -- 42,000 5,000 5,000 -- 5,000 -- 1 2 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- 15a 15a 15b -- -- -- 65,000 65,000 -- -- -- 65,000 5,000 5,000 -- 15 - 40 15 - 50 1 2 120 120/240 -- -- 10a, 11a, 12a 10,000 10a, 11a, 12a -- -- 10,000 -- -- P, GF 15 - 30 15 - 50 1 2 120 120/240 -- -- 10a, 11a, 12a 22,000 10a, 11a, 12a -- -- 22,000 P, GFEP 15 - 40 15 - 50 1 2 120 120/240 -- -- -- -- 10,000 -- QPHGFEP P, GFEP QPHGFEP 15 - 30 15 - 30 1 2 120 120/240 -- -- -- -- 22,000 22,000 120 Page Number DC AC Ratings Volts 80 -- 5,000 -- 11-4 11-4 11-4 -- 5,000 -- 11-4 11-4 11-4 -- 5,000 -- 11-4 11-4 11-4 5,000 -- -- 5,000 -- 11-4 11-4 11-4 -- -- -- -- -- -- 11-5 11-5 -- -- -- -- -- -- -- -- 11-5 11-5 -- 10,000 -- -- -- -- -- -- -- -- 11-5 11-5 -- 22,000 -- -- -- -- -- -- -- -- 11-5 11-5 QUICKLAG circuit breakers are suitable for application in relative humidity 0 - 95% non-condensating. Two-pole DC interrupting ratings based on 2 poles connected in series. 62.5V AC interrupting rating is 3800 AIC 10 - 50 amperes and 2500 AIC 55 - 100 amperes continuous. Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA. For Types GHBS, GBHS and BABR Solenoid-Operated, Remote-Controlled Circuit Breakers, see Pages 11-14 - 11-15. For Types WMS and SPHM Supplementary Protectors, see Pages 11-23 and 11-34. For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E 11 Industrial Circuit Breakers January 2001 Vol. 1, Ref. No. [0435] QUICKLAG Quick Reference Tables 11-1. QUICKLAG Industrial Circuit Breakers Plug-In, Bolt-On, Cable-In/Cable-Out (Continued) Circuit Breaker Type Circuit Continuous Number Breaker Ampere of Poles Type Code Rating @ 40C BAB BAB BAB B BABR BABR Volts AC DC Federal Spec. W-C-375b Interrupting Ratings rms Symmetrical Amperes DC AC Ratings Volts 120 120/240 240 24-48 62.5 Page Number 80 10 - 70 10 - 125 10 - 100 1 2 2, 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- 10a, 11a, 12a 10a, 12a 10b, 11b, 12b -- -- -- 10,000 10,000 -- -- -- 10,000 5,000 5,000 -- 5,000 -- -- 5,000 -- 11-6 11-6 11-6 B 15 - 30 15 - 30 1 2 120 120/240 -- -- -- -- 10,000 -- -- 10,000 -- -- -- -- -- -- -- -- 11-13 11-13 QBHW QBHW QBHW B 15 - 70 15 - 125 15 - 100 1 2 2, 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- 14a 14a 14b -- -- -- 22,000 22,000 -- -- -- 22,000 5,000 5,000 -- 5,000 -- -- 5,000 -- 11-6 11-6 11-6 HBAX HBAX HBAX B 15 - 70 15 - 100 15 - 100 1 2 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- -- -- -- -- -- 42,000 42,000 -- -- -- 42,000 5,000 5,000 -- 5,000 -- -- 5,000 -- 11-6 11-6 11-6 HBAW HBAW HBAW B 15 - 30 15 - 30 15 - 20 1 2 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- 15a 15a 15b -- -- -- 65,000 65,000 -- -- -- 65,000 5,000 5,000 -- 5,000 -- -- 5,000 -- 11-6 11-6 11-6 QBGF QBGF B, GF 15 - 40 15 - 50 1 2 120 120/240 -- -- 10a, 11a, 12a 10a, 11a, 12a 10,000 -- -- 10,000 -- -- -- -- -- -- -- -- 11-7 11-7 QBHGF QBHGF B, GF 15 - 30 15 - 30 1 2 120 120/240 -- -- 10a, 11a, 12a 10a, 11a, 12a 22,000 -- -- 22,000 -- -- -- -- -- -- -- -- 11-7 11-7 QBGFEP QBGFEP B, GFEP 15 - 40 15 - 50 1 2 120 120/240 -- -- -- -- 10,000 -- -- 10,000 -- -- -- -- -- -- -- -- 11-7 11-7 QBHGFEP QBHGFEP B, GFEP 15 - 30 15 - 30 1 2 120 120/240 -- -- -- -- 22,000 22,000 -- 22,000 -- -- -- -- -- -- -- -- 11-7 11-7 QC QC QC C 10 - 70 10 - 100 10 - 100 1 2 2, 3, 4 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- 10a, 11a, 12a 10a, 12a 10b, 11b, 12b -- -- -- 10,000 10,000 -- -- -- 10,000 5,000 5,000 -- 5,000 -- -- 5,000 -- 11-9 11-9 11-9 QCF QCF QCF QCR QCR QCR C 10 - 60 15 - 20 15 - 30 10 - 60 15 - 20 15 - 30 1, 2 1, 2 2, 3 1, 2 1, 2 2, 3 120/240 120/240 240 120/240 120/240 240 24, 48, 62.5 24, 48, 62.5 24, 48, 62.5 24, 48, 62.5 24, 48, 62.5 24, 48, 62.5 -- -- -- -- -- -- 10,000 22,000 -- 10,000 22,000 -- 10,000 -- 10,000 10,000 -- 10,000 -- -- -- -- -- -- 3,000 3,000 3,000 3,000 3,000 3,000 3,000 3,000 2,000 3,000 3,000 -- -- -- -- -- -- 11-10 11-10 11-10 11-10 11-10 11-10 QCHW QCHW QCHW C 15 - 70 15 - 100 15 - 100 1 2 2, 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- 14a 14a 14b -- -- -- 22,000 22,000 -- -- -- 22,000 5,000 5,000 -- 5,000 -- -- 5,000 -- 11-9 11-9 11-9 QHCX QHCX QHCX C 15 - 70 15 - 100 15 - 100 1 2 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- -- -- -- -- -- -- 42,000 42,000 -- -- -- 42,000 5,000 5,000 -- 5,000 -- -- 5,000 -- 11-9 11-9 11-9 QHCW QHCW QHCW C 15 - 30 15 - 30 15 - 20 1 2 3 120/240 120/240 240 24, 48, 62.5 24, 48, 80 -- 15a 15a 15b -- -- -- 65,000 65,000 -- -- -- 65,000 5,000 5,000 -- 5,000 -- -- 5,000 -- 11-9 11-9 11-9 QCGF QCGF C, GF 15 - 40 15 - 50 1 2 120 120/240 -- -- -- -- 10,000 -- -- 10,000 -- -- -- -- -- -- -- -- 11-13 11-13 QCHGF QCHGF C, GF 15 - 30 15 - 30 1 2 120 120/240 -- -- -- -- 22,000 -- -- 22,000 -- -- -- -- -- -- -- -- 11-13 11-13 QCGFEP QCGFEP C, GFEP 15 - 40 15 - 50 1 2 120 120/240 -- -- -- -- 10,000 -- -- 10,000 -- -- -- -- -- -- -- -- 11-13 11-13 QCHGFEP QCHGFEP C, GFEP 15 - 30 15 - 30 1 2 120 120/240 -- -- -- -- 22,000 -- -- 22,000 -- -- -- -- -- -- -- -- 11-13 11-13 QUICKLAG circuit breakers are suitable for application in relative humidity 0 - 95% non-condensating. Two-pole DC interrupting ratings based on 2 poles connected in series. 62.5V AC interrupting rating is 3800 AIC 10 - 50 amperes and 2500 AIC 55 - 100 amperes continuous. Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA. For Types GHBS, GBHS and BABR Solenoid-Operated, Remote-Controlled Circuit Breakers, see Pages 11-14 - 11-15. For Types WMS and SPHM Supplementary Protectors, see Pages 11-23 and 11-34. CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog 11-22 Industrial Circuit Breakers January 2001 Vol. 1, Ref. No. [0454] QUICKLAG -- Factory Modifications and Installed Terminals Factory Modifications and Installed Terminals Table 11-29. Factory Modifications Type of Modification Breaker Types Catalog Suffix QUICKLAG Types P, B and C QUICKLAG Types P, B and C S S1 Special Calibration (50C) Shock Testing Freeze Testing QUICKLAG Types P, B and C QUICKLAG Types P, B and C QUICKLAG Types P, B and C V L Y Moisture-Fungus Treatment Marine Duty Naval Duty 400 Hz Calibration Specific DC Ratings (Breaker marked with a Max VDC rating) QUICKLAG Types P, B, C and Ground Fault QUICKLAG Types P, B, C QUICKLAG Types P, B, C QUICKLAG Types P, B, C QUICKLAG Types P, B, C F H08 H09 G Q thru Q9 Shunt Trip (Requires 1 extra pole space on right side) 120, 208, 240V AC 12, 24, 48V AC/DC Draws 2.6A at 120V Draws 11A at 24V DC Adder U.S. $ 138.00 20% 30% 30% 15.00 10% 10% 20% 20% Contact Cutler-Hammer for factory modifications available for QCR and QCF breakers. Q = 32V DC; Q1 = 32 - 40V DC; Q2 = 37.5V DC; Q3 = 45V DC; Q4 = 48V DC; Q5 = 50V DC; Q6 = 62V DC; Q7 = 75V DC (2P); Q8 = 80V DC (2P); Q9 = 125V DC (QCR 2P) Table 11-30. Factory Installed Breaker Terminals Breaker Type Continuous Standard Line Terminal Ampere Rating Term Wire Wire Type Type Range (AWG) Term Type Wire Type Wire Range (AWG) Line Load QUICKLAG Type P HQP, QPHW, QHPX, QHPW 10 to 30 35 to 50 55 to 125 Plug-on female clips which mate with the bus stabs 1 2 3 Cu/Al Cu/Al Cu/Al 14 - 4 14 - 4 8 - 1/0 N/A 3 3 -- QUICKLAG Ground Fault QPGF, QPHGF, QPGFEP, QPHGFEP 10 to 30 Plug-on female clips which mate with the bus stabs 1 (1-pole) 4 (2-pole) 4 Cu/Al Cu/Al Cu 14 - 4 14 - 8 14 - 8 N/A 3 3 -- QUICKLAG Type B BAB, QBHW, HBAX, HBAW 10 to 30 35 to 50 55 to 125 Extended tangs which bolt directly to the bus 1 (1- and 2-pole) 2 (3-pole) 3 Cu/Al Cu/Al Cu/Al 14 - 4 14 - 4 8 - 1/0 N/A 3 3 -- QUICKLAG Ground Fault QBGF, QBHGF, QBGFEP, QBHGFEP 10 to 30 Extended tangs which bolt directly to the bus 1 (1-pole) 4 (2-pole) 4 Cu/Al Cu/Al Cu 14 - 4 14 - 8 14 - 8 N/A N/A QUICKLAG Type C QC, QCHW, QHCX, QHCW 10 to 20 25 to 60 70 to 100 5 6 7 Cu/Al Cu/Al Cu/Al 14 - 10 14 - 10 14 - 10 5 2 3 Cu/Al Cu/Al Cu/Al 14 - 10 14 - 4 8 - 1/0 6, 7 5, 7 5 6, 7, 8 5, 6, 7, 8 5, 7, 8 QUICKLAG QCR, QCF 10 to 55 60 1 1 Cu/Al Cu 14 - 4 14 - 4 1 1 Cu/Al Cu 14 - 4 14 - 4 N/A N/A QUICKLAG Ground Fault 10 to 20 QCGF, QCHGF, QCGFEP, QCHGFEP 25 to 50 5 6 Cu/Al Cu/Al 14 - 10 14 - 10 1 1 Cu/Al Cu/Al 14 - 4 14 - 4 6, 7 5, 7 5 5 11 1 40 40 2 Steel Box Lug 5 Standard Load Terminal Optional Terminals (20% List Price Adder) 3 4 Steel Box Lug 6 Steel Box Lug Aluminum Box Lug 7 8 Steel Ring Type Aluminum Box Lug 4-Prong Quick Connect Catalog Suffix P Aluminum Box Lug Clamp on line side only. Table 11-31. Spare Terminal Hardware Screws (Lugs not Included) Terminal Type Description Order in Multiples of Catalog Number 1 2 3 5 6 and 7 QUICKLAG Terminal Screw QUICKLAG Terminal Screw QUICKLAG Terminal Screw QUICKLAG Binding Head Terminal Screw and Clamp QUICKLAG Terminal Screw 10 10 10 10 10 QLLDTSA QLLDTSB QLLDTSC QLBHTSE QLLNTSFG Price U.S. $ .21 .21 2.80 2.80 2.80 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CB-1 For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E