HEAVY DUTY VOLTAGE OUTPUT
PRESSURE TRANSDUCER
WITH G 1/8 OR 1/4 FITTING
PXM41 Series
0.5 to 5.5 Vdc Output
0-1 to 0-400 bar
®
OMEGADYNE
FM
APPROVED
1 bar = 14.5 psi
1 kg/cm2= 14.22 psi
1 Atmosphere = 14.7 psi
= 29.93 in-Hg = 760.2 mm-Hg
= 1.014 bar
FM Approved Intrinsically
Safe Standard
Special MSHA Approved
Model Available
All Stainless Steel Body
Heavy Duty Construction
Harsh Environments
Available in Gauge,
Sealed Gauge and
Absolute Pressure
OMEGA’s PXM41 Series is a high
accuracy, rugged, low cost 5V
output, industrial pressure
transducer. Its all stainless steel
construction makes it suitable for the
harshest environments. The PXM41
is available in gauge, absolute or
sealed models. Three metres of four
conductor shielded cable is
standard. Twist-lock style or Micro
DIN connectors are also available. A
wide selection of amplified voltage
and current output models in the
PXM41 family makes this a truly
versatile family of industrial
transducers.
SPECIFICATIONS:
Excitation: 10-35 Vdc
Output: 0.5 to 5.5 Vdc; adj± 10%
Zero Balance: 0.5 V; adj ±10% FSO
Agency Approval:
FM Intrinsically Safe:
IS/I.II.III/1/CDEFG - Standard
FM Hazardous Location: Optional
IS/I/1/ABCD (4-20 mA output only)
Accuracy: 0.25% FS Linearity and
Hysteresis Combined
Model PXM41MC6-006BARG5V
Shown smaller than actual size
MOST POPULAR MODELS HIGHLIGHTED
Model PXM41MC0-006BARG5V
Shown smaller than actual size
$450
Models Shown
To Order (Specify Model Number)
Models with G 1/4 Female Pressure Connection, Cable or Connector and 0.5-5.5V Output
RANGE (Bar) MODEL NUMBER PRICE COMPATIBLE METERS**
Gauge Pressure
0 to 1 PXM41MD0-[*]-001BARG5V $500 i series, DP41-E, DP25B-E
0 to 1.6 PXM41MD0-[*]-1.60BARG5V 500 i series, DP41-E, DP25B-E
0 to 2.5 PXM41MD0-[*]-2.50BARG5V 450 i series, DP41-E, DP25B-E
0 to 4 PXM41MD0-[*]-004BARG5V 450 i series, DP41-E, DP25B-E
0 to 6 PXM41MD0-[*]-006BARG5V 450 i series, DP41-E, DP25B-E
0 to 10 PXM41MD0-[*]-010BARG5V 450 i series, DP41-E, DP25B-E
0 to 16 PXM41MD0-[*]-016BARG5V 450 i series, DP41-E, DP25B-E
0 to 25 PXM41MD0-[*]-025BARG5V 450 i series, DP41-E, DP25B-E
0 to 40 PXM41MD0-[*]-040BARG5V 450 i series, DP41-E, DP25B-E
0 to 60 PXM41MD0-[*]-060BARG5V 450 i series, DP41-E, DP25B-E
0 to 100 PXM41MD0-[*]-100BARG5V 450 i series, DP41-E, DP25B-E
0 to 160 PXM41MD0-[*]-160BARG5V 450 i series, DP41-E, DP25B-E
0 to 250 PXM41MD0-[*]-250BARG5V 450 i series, DP41-E, DP25B-E
0 to 400 PXM41MD0-[*]-400BARG5V 450 i series, DP41-E, DP25B-E
[*] = insert “0” for 3 m Cable, “6” for micro DIN connector or “1” for PTIH-10-6P twist
lock connector.
** See Section D for Compatible Meters.
To order Sealed Gauge Pressure models, replace “G” in model number with “S”.
To order Absolute Pressure models replace “G” in model number with “A”.
Ordering Examples:
1.) PXM41MD6-025BARG5V is a 25 bar Gauge Pressure transducer with G 1/4 internal
thread, micro DIN, and 0.5 to 5.5 Vdc output, $450.
2.) PXM41MD0-1.60BARA5V is a 1.6 bar Absolute Pressure transducer with G 1/4
internal thread, 3 metre cable, and 0.5 to 5.5 Vdc output, $450.
B-235
USA
MADE IN
B
METRIC SPEC
PRESSURE TRANSDUCERS
HEAVY DUTY INDUSTRIAL TRANSDUCER
1/2-14 NPT
SIDE VIEW
19.1
(.75)
28.6
(1.125)
MAX
88.9 (3.5)
MAX
3 m (10 ft) 4-CONDUCTOR
CABLE
28.6 (1.125 HEX)
ZERO ADJUSTMENT
SPAN OTHER SIDE
G 1/4 or G 1/8
External
31.8 DIA
(1.25)
G1/4
21 (.83)
OR
G1/8
18 (.71)
HEX
G 1/4 or G 1/8
Internal
SPECIFICATIONS (con’t):
Operational Temp Range:
-47 to +121°C (-50 to +250°F)
Compensated Temp Range:
16 to 71°C (60 to 160°F)
Thermal Effects:
Span: 0.0054% of Rdg/°C
Zero: 0.009% of FSO/°C
Proof Pressure:
150% of rated pressure
Burst Pressure:
300% of rated pressure
Wetted Parts: 17-4 PH Stainless Steel
Pressure Port: G 1/4 Male (std) or
Female, G 1/8 Male or Female
Electrical Connection:
3 m (10 ft) 4-conductor cable
PXM41MC1-006BARG5V
OPTION CODES (add to end of model number)
–FM FM hazardous locations, "I" output only
–MSHA Mine Safety and Health Admin, "5V" or "I" output
–OX (cleaned for oxygen use)
–[ ]m Optional cable lengths
Example: -12 m = 12 metres total of cable)
OUTPUT: 5V = 0.5 to 5.5 Vdc
5T = 0 to 5 Vdc
10 V = 0.5 to 10.5 Vdc
10T = 0 to 10 Vdc
I = 4 to 20 mA
UNITS (A = absolute, S = sealed gauge, G = gauge)
RANGE
ELECTRICAL CONNECTION:
0 = 3 m cable
1 = PTIH-10-6P connector or equiv.
5 = lightening protection amplifier box
(4-20 mA models only)
6 = micro DIN connector
PRESSURE PORT: MA = G 1/8 male
MB = G 1/8 female
MC = G 1/4 male
MD = G 1/4 female
–MODEL NUMBER SPECIFICATION:
CUSTOM CONFIGURATIONS
Wiring Connections
Cable DIN
Input + Red 1
Out + Green 2
Out - White 3
Input - Black 4
G 1/4 Pressure
Snubbers $20
PSM-4 =G 1/4
Ordering Examples:
1.) PXM41MC1-006BARG5V, a 6 bar Gauge Pressure transmitter with G 1/4 external thread, a PTIH-10-6P Connector, and 0.5 to 5.5 Vdc
output, $450. Mating Connector (not included) PT06F-10-6S, $26.50.
2.) PXM41MC0-060BARSI, a 60 bar Sealed Gauge pressure transmitter with G 1/4 external thread, a 3 m cable, and 4 to 20 mA output, $480.
3.) PXM41MB1-01.6BARA5V, a 1.6 bar Absolute Pressure transmitter with G 1/8 internal thread, a PTIH-10-6P Connector, and 0.5 to 5.5 Vdc
output, $500. Mating Connector (not included) PT06F-10-6S, $26.50.
B-236